Sec. 11-122. - Mechanical equipment.
(a) Performance requirements. (1) Every dwelling and rooming unit shall have heating facilities which are properly installed and are capable of safely and adequately heating all habitable rooms, bathrooms and toilet rooms located therein to a temperature of at least 68 degrees Fahrenheit (20 degrees Celsius) at a distance of three feet above the floor level at all times. The heating facilities shall be so designed and equipped that heat, as specified in this subsection, is available for all dwelling units and rooming units. (2) Every fuel-burning heating unit or water heater shall be effectively vented in a safe manner to a chimney or duct leading to the exterior of the building. The chimney or duct shall be of such design as to ensure proper draft, and shall be adequately supported. (3) Every central heating unit, space heater, water heater and cooking appliance shall be located and installed in such a manner as to afford reasonable protection against involvement of egress facilities or egress routes in the event of uncontrolled fire in the structure. (4) No fuel-burning furnace or water heater shall be located within any sleeping room or bathroom unless there is adequate combustion air, an automatic shutoff is provided and the continuing operation of the furnace or water heater poses no threat to the occupants, as determined by the city mechanical inspector. (5) Every steam or hot water boiler and every water heater shall be protected against overheating by appropriate automatic pressure and temperature limit controls. (6) Every fuel-burning space heating unit and water heater shall be equipped with an electronic ignition device or with a pilot light and a control to interrupt the flow of fuel to the unit in the event of failure of the ignition device. (b) Structural requirements. (1) Such equipment shall be installed and maintained in a safe condition and in accordance with applicable codes and manufacturer's specifications. (2) Installation of natural gas and associated equipment shall be governed by the provisions of chapter 7. (c) Acceptability criteria. Acceptability criteria are the same as performance and structural requirements. All heating devices or appliances shall be of an approved type. Unvented room heaters which burn gas, oil or kerosene are unacceptable.
(Code 2017, § 14-99; Ord. No. 2178, § 1, 2-24-1997; Ord. No. 2744, § 9, 4-25-2011)
Ask a question about Cedar Falls law
Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.