§ 11-121 — Natural light, natural ventilation and mechanical ventilation

Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 11-121

Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/71eeda29-5d04-49b7-bd21-958d5208682a

Sec. 11-121. - Natural light, natural ventilation and mechanical ventilation.

(a) Performance requirements. (1) All habitable rooms within a dwelling unit or rooming unit shall be provided with natural light by means of exterior glazed openings with an area of not less than one-tenth of the floor area of such rooms, with a minimum of ten square feet. All bathrooms, water closet compartments, laundry rooms and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area of not less than of the floor area of such rooms, with a minimum of one square feet. (2) All habitable rooms within a dwelling unit or rooming unit shall be provided with natural ventilation by means of openable exterior openings with an area of not less than of the floor area of such rooms, with a minimum of five square feet. (3) In lieu of required exterior openings for natural ventilation, a mechanical ventilation system may be provided. Such system shall be capable of providing two air changes per hour in all habitable rooms. One-fifth of the air supply shall be taken from the outside. In bathrooms, water closet compartments, laundry rooms and similar rooms, a mechanical ventilation system connected directly to the outside, capable of providing five air changes per hour, shall be provided. (b) Structural requirements. (1) Every window or other device with an opening to the outdoor space which is capable of being used for ventilation purposes shall be maintained in a good state of repair. This will include screens, if applicable. (2) Every door opening directly from a dwelling unit or rooming unit to the outdoor space shall fit reasonably tightly within its frame and shall be maintained in good order and a good state of repair. (3) Additional structural requirements are set out in subsections (a)(1) through (3) of this section. (c) Acceptability criteria. Every dwelling unit or rooming unit shall have natural light and natural ventilation. Mechanical ventilation may be substituted in lieu of natural ventilation. Exterior openings or mechanical systems shall be maintained in good working condition to ensure an appropriate climate for a healthy living environment.

(Code 2017, § 14-98; Ord. No. 2178, § 1, 2-24-1997)

Ask a question about Cedar Falls law

Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.