For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 26-193.2 — Urban general frontages

Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 26-193.2

Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/64699833-788c-415e-8182-e85baf6c5b63

Sec. 26-193.2. - Urban general frontages.

A. Illustrations and intent. The Urban General frontage is the basic American "downtown" building frontage, once typical in towns and cities across the United States. Multi-story buildings with closely spaced entrances and windows are lined up shoulder to shoulder behind the sidewalk, filling out the block-face. This frontage is for street-oriented, downtown-type buildings. These building forms can accommodate a range of uses, allowing retail shopfronts, office or residential buildings, and/or mixed-use buildings, with service access and parking lots in the block interior, accessed from the alley. [image omitted; see the official code] B. Example Building Configurations and Placement. Note: These diagrams illustrate some of the building configurations possible under the placement standards on the following page. They do not represent fully designed buildings nor do they fully address issues such as parking or the International Building Code. Refer to the following pages for the specific standards of the Urban General Frontage. [image omitted; see the official code] The Urban General frontage standards provide a great deal of flexibility. Once the minimum height and frontage buildout requirements are met, the building behind the facade can take most any configuration. These diagrams, aligned above the placement diagram from the standards on the following pages, illustrate a few of the possible configurations a building can take under the General Urban building form standards. The green area represents the required private open area—which in Urban General frontages may be on or above ground, including on the roof. Diagram 1 shows a simple bar building. The facade meets the required percentage build-out and minimum height and has a street wall spanning the unbuilt required building line. The private open area is provided on the roof, with additional rear yard area. The building is likely configured with units facing the street or the rear yard. A surface parking lot is accessed from the alley. Diagram 2 shows a building with a forecourt entry. The facade spans most of the required building line to meet its build-out requirement—the forecourt takes advantage of the percentage of the frontage not required to have a building on it. The private open area is provided on the roof, with additional rear yard area. Parking for the building is directly off the alley. Diagram 3 shows a building with a lower, rear "L" section. The private open area requirement is met with a rear yard. This diagram suggests basement-level parking, accessed from the alley. Larger buildings may have to meet parking requirements with a combination of inside/under the building, and/or off-site arrangements. Diagram 4 shows a building with a central courtyard, providing a shared private open area for its occupants. This diagram also suggests semi-basement level parking, under the elevated first floor and accessed from the alley. Diagram 5 is a re-oriented placement diagram for the Urban General frontages, provided for reference. The red dashed line is the required building line, the blue dashed line is the parking setback line, the gray area is the buildable area, and the green rectangle within it represents the private open area. This is more fully explained in the frontage standard itself, located on the following pages. [image omitted; see the official code] C. Placement. 1. Facade. a. On each lot the building facade shall be built to the required building line (RBL) for at least: i. Urban General: 80 percent of the RBL length. ii. Urban General 2: 70 percent of the RBL length. b. A street wall is required on any unbuilt required building line. c. Within 12 feet of the block corner, the ground story facade may be chamfered to form a corner entry. d. A forecourt configuration may be used within the minimum build-to parameters provided: i. All elevations facing the forecourt are regulated as facades; ii. The forecourt depth is no more than 20 feet and the width between 15 feet and 30 feet; iii. The forecourt may not be used for parking, drop-off driving area or storm-water management; iv. The forecourt opening does not require a street wall. e. In case of conflict, these standards shall supersede vision triangle requirements in the Code of Ordinances. 2. Buildable area. a. The buildable area is delineated by the gray area in the diagram above. b. The required building line is indicated on the regulating plan. It is generally located one foot off the ROW/property line for Urban General and five feet off for Urban General 2. The exact position of the RBL should be confirmed in consultation with the zoning administrator and ZRC. c. Setbacks: there are no required side setbacks; rear setbacks are: Eight feet from an alley and 15 feet if no alley. d. The maximum building footprint is 25,000 square feet. e. A private open area equal to at least 15 percent of the buildable area must be provided on every lot. f. The minimum private open area dimension is 18 feet. g. Up to 33 percent of the required private open area may be satisfied by the balconies of individual units which are exempt from the minimum dimension in f. above, and parking setback line restrictions in h. and i. below. (See 193.1, General standards, C, Elements, 2.f, Balconies, for qualifying balcony requirements.) h. The private open area must be located behind the parking setback line when it is below the third story. i. Where provided at or above the third story, the private open area may be located forward of the parking setback line (such as in a raised courtyard configuration) only if: i. It opens onto no more than one street-space, and ii. Is set back at least 30 feet from any block corner or building corner. j. When on the building's highest roof level, the private open area may be located anywhere on the roof. 3. Other. a. The parking setback line is indicated on the regulating plan, generally 30 feet behind the required building line, with limited exceptions at alley/RBL intersections. See F.4, Rear lot area below. b. A privacy fence is permitted and may be required. See section 26-193.1.E, Neighborhood manners. [image omitted; see the official code] D. Height. See section 26-193.1.B. for information about measuring height. 1. Building height. a. Urban General: Minimum at RBL two stories, maximum four stories and 52 feet. b. Urban General 2: Minimum at RBL two stories, maximum three stories and 42 feet. c. Story heights may be different for specific locations; refer to the regulating plan. 2. Ground floor finished elevation. a. For commercial or retail: -six inches to +18 inches. b. For residential units within 30 feet of the required building line: Three feet to five feet. Entrances may be at grade, with transitions within the building to meet the minimum finished floor elevation for the units. Support functions such as lobbies, rental offices, and club rooms may be located at grade. 3. Second floor finished elevation. a. Urban General: Sixteen feet to 22 feet. b. Urban General 2: Sixteen feet to 18 feet. 4. Ground story finished clear height. a. For commercial or retail: Thirteen feet minimum. b. For residential: Nine feet minimum. 5. Upper stories finished clear height: Nine feet minimum. 6. Street wall: Four feet to eight feet. 7. Privacy fence: Eight feet maximum, measured from adjacent grade. [image omitted; see the official code] E. Elements. 1. Fenestration, ground story: Fifty to 80 percent. 2. Fenestration, upper stories: Twenty to 80 percent. 3. Attic story: permitted within the parameters of sections 193.C.3. above and 194.D, Architecture. 4. Balconies: (Applicable where a balcony is used to contribute to the private open area calculation): Minimum depth five feet, minimum width nine feet. 5. Facade entry doors: Maximum door to door distance: a. Urban General: Seventy feet. b. Urban General 2: Eighty feet. c. All upper story uses must be directly accessible from the street-space through a facade entry. Unenclosed or partially enclosed exterior staircases may not be used to access upper story units. [image omitted; see the official code] F. Uses. See section 26-197, Building functions, for specific parameters and/or performance standards. 1. Ground story: a. Urban General: Nonresidential or residential. b. Urban General 2: Nonresidential or residential. c. Residential uses are permitted on all stories. See the height standards, above for specific configuration standards for ground story residential. 2. Upper stories: Residential or nonresidential (no retail). a. Nonresidential uses are not permitted above a residential use. b. Retail is only permitted in a second story where it is an extension of a ground story retail business and is no larger in gross floor area than that ground story retail space. 3. Attic story: Residential or nonresidential. Additional habitable space is permitted within the roof where it is configured as an attic story. 4. Rear lot area: a. In addition to the other permitted ground story uses, parking and loading is permitted behind the parking setback line. b. For lots with an alley/required building line intersection, where there is an additional parking area designated on the regulating plan, parking is permitted in this area when: i. It is within a building and under a habitable second story; ii. The facade of the building enclosing the parking meets all requirements; iii. It is two feet off the front of the required building line; and iv. Within 62 feet of the rear lot line. c. See also additional parking location exceptions specified in 26.193.1A.6.

(Ord. No. 2994, § 9(Att. A), 11-1-2021; Ord. No. 3041, § 2, 9-18-2023)

Ask a question about Cedar Falls law

Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.