For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 26-193.3 — Storefront frontage

Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 26-193.3

Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/ebe85fd7-91ce-49da-868f-889dee0bc083

Sec. 26-193.3. - Storefront frontage.

[image omitted; see the official code] A. Illustrations and intent. Note: These photos and statements are provided as illustrations of intent and are advisory only. They are not regulatory. Refer to the standards on this page and the previous pages for the specific rules of the storefront building form standard. This is the quintessential American "main street" frontage, with retail and restaurant uses on the ground floor and residences or offices upstairs. The overall building form is the same as the Urban General frontage, but with large display windows across the ground floor facade and frequent entrances along the street. Display windows should be large to allow unimpeded views into the interior of the shop. Closely spaced mullions or muntins, punched windows, and horizontal grids should be avoided. B. Storefront Frontage Specifications. Where the storefront frontage is designated on the regulating plan, the ground story configuration shall be that of a shopfront. The BFS standards for Urban General apply with the following exceptions and modifications: 1. Fenestration: ground story: Seventy to 90 percent. 2. Frontage build-to minimum: Eighty-five percent. 3. Ground story uses: Within 30 feet of the required building line, uses are limited to nonresidential categories. Frontages on Main Street between 1st and 6th Streets are generally limited to retail sales and service, and eating and drinking establishments. A lobby and/or entry, serving an upper STORY use, is permitted on the ground story. At the owner's discretion, that lobby or entry portion of the facade may be governed by the Urban General or the storefront frontage standards. See section 26-197, Building functions, for specific parameters and/or performance standards. 4. Shopfront encroachment: Up to two feet. The shopfront may encroach beyond the required building line into the dooryard, but not into the clear walkway or right-of-way. 5. Facade entry doors: Maximum door to door: Fifty feet.

(Ord. No. 2994, § 9(Att. A), 11-1-2021)

Ask a question about Cedar Falls law

Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.