§ 26-194 — Architectural standards
Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 26-194
Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/255e3e54-e6f2-4716-9396-2211f0bd6755
Sec. 26-194. - Architectural standards.
A. General Purpose and Intent. The primary purposes of the architectural standards, working in tandem with section 26-193, Building form standards, is to complement and reinforce the pedestrian environment and street-space of the Character Districts through the application of high quality materials and architectural designs. These standards are intended to result in construction that is simple and functional, includes sustainable elements, and that will result in quality development that uses durable materials and design. A wide range of architectural expressions, from traditional to contemporary, can be achieved through these standards. The character of new building facades should complement the materials and general scale of surrounding district buildings and, through application of these standards, create a cohesive ensemble of buildings within the Character District. These architectural standards include basic parameters for functional building element configurations and a palette of exterior building materials. In order to establish and maintain a sense of place, these standards specify an architectural aesthetic of load-bearing walls and regional materials. The standards also specify details, such as window proportions, roof or cornice configurations, shopfronts, and overhangs. Buildings should reflect and complement the traditional materials and techniques of the greater Cedar Falls region. B. General Principles. 1. Applicability: a. These standards apply to all new construction within the Character Districts, unless otherwise expressly stated in this section. See section 26-63, Proportionate compliance, for specific applicability when remodeling or renovating existing structures. b. Where clearly visible from the street-space: (i) Many of these standards apply only where clearly visible from the street-space. Note that the definition of street-space includes parks, squares, and civic greens but not alleys. (ii) These controls concentrate on the public realm and views from the public realm, and minimize interference in the private realm. For example, an architectural element that is visible only through an opening in a street wall is not clearly visible from the street. 2. Materials. a. All building materials shall express their structural properties. For example, stronger and heavier materials (masonry) should be located below lighter materials (wood). Material changes should occur at logical construction locations (such as at an inside corner). b. Equivalent or better: Materials, techniques, and product types listed in this section are prescribed. Where indicated, materials that are equivalent or better may be proposed to the zoning administrator and ZRC for review according to the minor adjustments process established in section 26-39, not including any materials specifically prohibited in the individual subsection. The zoning administrator will maintain a list of approved materials containing materials that have met this standard and are therefore permitted under this section. C. Architectural Standards: Building Walls. 1. Purpose and Intent. Building facades define the public realm, or street-space. All walls should express the construction techniques and structural constraints of their building materials. These standards are intended to achieve simple configurations and solid craftsmanship. Photographs are provided as illustrations of intent, with no regulatory effect. They shall not imply that every element in the image is permitted. Refer to the standards on the following page for the specific requirements of this section. [image omitted; see the official code] 2. Applicability. The standards in this section apply to all building walls that are clearly visible from the street-space. Where expressly stated, they also apply to additional building elevations. 3. Primary facade materials. a. Any of the following building materials shall be used on a minimum of 75 percent of the facade area. This measurement shall be calculated as a percentage of the wall portion of the facade, exclusive of fenestration. (i) Brick and terra cotta; (ii) Natural stone; (iii) Stucco (cement plaster); prefabricated stucco panels and sprayed on stucco finishes are prohibited; (iv) Cast iron, copper, stainless steel (18-8 or better), or titanium metal. b. For neighborhood frontages only: (i) Wood or approved fiber cement siding; (ii) Vinyl siding may be used on residential buildings with six or fewer dwelling units only, except as noted in the paragraph (iii) below; (iii) On other buildings with existing vinyl siding, that siding may be replaced or repaired with vinyl siding and any additions may be clad with vinyl siding. c. Additional materials may be proposed to the zoning administrator and ZRC for review under the equivalent or better standard, see section B.2.b above. 4. Secondary materials. Any of the following materials are permitted on a maximum of 25 percent of the facade area and on all side and rear elevations. a. All permitted primary materials; b. Metal (heavy gauge & non-reflective); c. Ground- or split-faced block (integrally colored); d. Glass block; e. Decorative tile; f. Pre-cast masonry; g. Durable foam-based products, such as Fypon, may be used for architectural detailing; and h. EIFS (Exterior Insulation and Finishing System) and other synthetic materials may be used above the second story, if on the ZRC Approved Alternate Materials List. 5. Prohibited materials. a. Styrofoam; b. Vinyl (except as noted above for neighborhood frontages) and aluminum siding. 6. Configurations and techniques. a. When different materials are used on a facade, heavier materials shall be used below lighter materials (i.e., stone below brick; brick below metal panel; brick below siding). b. All masonry, including brick, block, and stone, shall be in an apparent load-bearing configuration. c. Where siding, including panels, is not mitered at corners, siding shall incorporate corner boards on the outside building corners to conceal raw edges. d. Wall openings (fenestration) must: (i) have a vertical dimension equal to or greater than the horizontal dimension unless otherwise specifically permitted in these district standards; (ii) correspond to the interior space and shall not span across building structure such as a floor or wall. e. Wood siding and wood simulation materials. (i) Horizontal siding shall be configured with a maximum board exposure of eight inches. (ii) Board and batten siding shall have a maximum board width of ten inches. (iii) Siding and shingles shall be smooth, not rough-sawn finish. (iv) Shall not come in contact with the ground surface. f. Stucco. (i) Shall have a smooth or sand finish only; no rough textured finish. (ii) Shall not come in contact with the ground surface. g. All exposed masonry walls (i.e., street walls, garden and other free-standing walls, and parapets) shall have a cap or coping to protect the top of the wall from weather. D. Architectural Standards: Roofs, Eaves and Parapets. 1. Purpose and intent. Roofs and parapets are part of the facade composition (its crown or hat) and contribute to the spatial definition of the street-space. They should demonstrate common-sense recognition of the climate by utilizing appropriate pitch, drainage, and materials in order to provide visual coherence to the district. Roof forms are not interchangeable. The roof type is integral to the design of the building and its architectural character and the configuration should be appropriate for the building and its facade. Photographs are provided as illustrations of intent, with no regulatory effect. They shall not imply that every element in the image is permitted. Refer to the standards on the following page for the specific requirements of this section. [image omitted; see the official code] 2. Applicability. The standards in this section apply to any roof or parapet that is clearly visible from the street-space. 3. Permitted roofing materials. a. Tile; b. Slate, and equivalent synthetic materials or better; c. Metal, shingle or standing seam, equivalent or better; d. Dimensional architectural grade composition shingles; or e. Wood shingles. 4. Prohibited roofing materials: Corrugated metal. 5. Additional permitted materials and elements. a. Cornices and soffits may be comprised of wood or metal. b. Gutters and downspouts may be vinyl and/or metal, in accordance with industry standards. c. Parapet wall materials, exclusive of copings, shall match the building wall. 6. Additional materials may be proposed to the zoning administrator and ZRC for review under the equivalent or better standard, see section B.2.b above. 7. Configurations and techniques. a. Flat roofs are allowed except in cottage court configurations. b. Pitched roofs. Roof pitch is measured as rise over run. For example, a 4:12 pitched roof increases four inches in height for every 12 inches of horizontal distance. (i) Roofs that cover the main body of a building shall have a slope of no less than 5:12 and no more than 12:12. (ii) The roofs of front porches, stoops, and balconies shall have a slope of no less than 2:12 and no more than 6:12. (iii) The end walls of a Dutch gable or gambrel roof may extend up above the roof line to form a parapet. (iv) Pitched roofs, except those on the facade side of the building, may be "cut out" to allow roof access for terraces and mechanical equipment. The cut out area may not be within 18 inches of end of the individual exterior wall nor within 18 inches of the roof ridge. c. Overhang requirements. (i) There shall be a ten to 30 inch overhang near the top of the primary structure, with the exception of parapet walls, which have a minimum overhang of three inches. This does not apply to walls on/at common lot lines or rear elevations. (ii) Buildings may satisfy the overhang requirement with eaves, a cornice, or similar form projecting horizontally from near the top of the building wall or above the ceiling of the uppermost story. d. Other elements. (i) Roof-mounted equipment is permitted only when screened from view (from the street-space) by the building's parapet wall. (ii) Skylights, solar shingles, and solar panels that are flat and flush to the roof are permitted; however, non-flat/flush panels should be mounted at least five feet from the roof outer edge/eaves or behind the parapet wall. E. Architectural Standards: Windows and Doors. 1. Purpose and intent. The placement, configuration, type, and size of windows and doors on the facade greatly influences the scale and character of the street-space. For Storefront frontages, windows allow interplay between the ground floor interiors and the sidewalk. Commercial uses (especially restaurants and retail establishments) benefit from exposure to the passers-by and the street-space benefits from the visual activity. For residences, windows foster the "eyes on the street" surveillance which provides for the security and safety for the area. Photographs are provided as illustrations of intent, with no regulatory effect. They shall not imply that every element in the image is permitted. Refer to the standards on the following page for the specific requirements of this section. [image omitted; see the official code] 2. Applicability. The standards in this section apply to any window or door that is clearly visible from the street-space. See section 26-63 for specific applicability when remodeling or renovating existing structures. Specific requirements and exceptions for shopfronts are provided in section F, Shopfronts, below. 3. Materials. a. Glass panes must be clear, with low reflectivity and light transmission at the ground story of at least 75 percent. Shopfront transoms are excluded from this restriction. b. Doors shall be of wood, clad wood, glass, steel, or any combination thereof. c. Shutter materials shall be wood or clad wood. d. Additional materials may be proposed to the zoning administrator and ZRC for review under the equivalent or better standard, see section B.2.b above. 4. Configurations and techniques. a. All Windows except shopfronts (see F, Shopfronts, below) (i) The horizontal dimension of the opening shall not exceed the vertical dimension except for transom windows above an entrance; (ii) Windows may be grouped horizontally if each grouping is separated by a mullion, column, pier, or wall section that is at least seven inches wide. A group is limited to a maximum of five windows; (iii) Windows should be subdivided to provide a pedestrian scale. The maximum dimensions for glass panes are 60 inches vertical by 36 inches horizontal. (iv) Window panes shall be recessed behind the surface of the facade a minimum of three inches, except for bay windows and shopfronts. (v) Windows must correspond to the clear height within a building and may not span across building structure such as floor structural and mechanical thicknesses. Windows on different story levels must be separated by a minimum 24-inch wall or framing element. (vi) Window types: Single-, double-, and triple-hung, hopper, awning, casement, clerestory, and transom. (vii) Fixed windows are only permitted as part of a window grouping that includes an operable window. (viii) Egress windows may be installed as required by the applicable building code. (ix) Snap-in mullions and muntin are permitted but not considered in any proportion calculation or measurements for fenestration. (x) Exterior shutters, when used, shall be sized and mounted appropriately for the window (one-half the width). b. Ground story windows and doors. (i) Double-height entryways (those that span more than one story) are not permitted. (ii) General and storefront facade doors shall not be recessed more than four feet [12] behind their facade and, in any case, shall have a clear view and path to a minimum 45-degree angle past the perpendicular from each side of the door into the street-space. Doors may not encroach into the right-of way when opened. c. Upper story windows. On all upper stories, a minimum of 40 percent of the window area, per story, must be operable. d. Garage doors. When a lot is adjacent to an alley, garage doors shall face towards the alley. F. Architectural Standards: Shopfronts. 1. Purpose and intent. Shopfronts enliven the public realm. They improve walkability, with frequent entrances and large display windows providing transparency and connection between the interior activity and the public sidewalk. Display windows should be large to allow unimpeded views into the interior of the shop. Closely spaced mullions or muntins, punched windows, and horizontal grids should be avoided. 2. Applicability. The standards in this section apply to building frontages designated as Storefront on the Character District regulating plan. They include more requirements than, and some exceptions to, the standards in section E, Windows and doors, above. Where there is an apparent conflict, these rules apply. Applicants may use the shopfront standards for any portion of a General Urban frontage, subject to ZRC approval. 3. Requirements and configurations. a. The bottom of shopfront window glass shall be between one and three feet above the sidewalk and shall run from the sill to a minimum of eight feet above the sidewalk. Materials per section C, Building walls, must be used below the window sill. b. Roll-up garage doors are not permitted for designated storefront frontages. c. Shopfront window and door glass shall be clear, with light transmission of at least 75 percent. Transom glass may be tinted, obscured, stained, or glass block. d. Individual panes of glass in shopfronts shall be no larger than 11 feet in height and six feet in width. e. Shopfront windows and doors may not be made opaque by window treatments, except by operable sunscreen devices within the interior. A minimum of 75 percent of the fenestration must allow views into the interior for a depth of at least ten feet. f. Shopfront doors must have at least 60 percent glass. Solid and opaque doors are prohibited. g. Shopfront doors must be distinguished by features such as: transom windows, awnings or canopies, or a recessed entryway. h. Shopfronts must be differentiated from the facade above by a projection or string course, with a minimum relief of one inch and minimum vertical width of three inches, between each shopfront and the window-sill level of the second story. Photographs are provided as illustrations of intent, with no regulatory effect. They shall not imply that every element in the image is permitted. Refer to the standards on the following page for the specific requirements of this section. [image omitted; see the official code] G. Architectural Standards: awnings and canopies. 1. Purpose and intent. Awnings and canopies provide protection from the elements and create shade and shadow on the building, enhance the three dimensional quality, add interest, and can help emphasize a primary building entrance. Open ended awnings are preferred to make blade signs and transom windows more visible from the sidewalk. 2. Applicability. The standards in this section apply to any awning or canopy that is clearly visible from the street-space. 3. Materials. a. Awning must be made of commercial-grade fabric and may be either fixed or retractable. High-gloss, plasticized, shiny or reflective materials are prohibited. b. Canopy framing shall be constructed of either metal or wood. c. Canopy roofing materials, where clearly visible from the street-space, may be: metal standing seam (5V crimp or equivalent), slate, glass, or durable fabric. d. Additional materials may be proposed to the zoning administrator and ZRC for review under the equivalent or better standard, see section B.2.b above. 4. Configurations. a. Awnings and canopies shall not interfere with utilities, street trees, or other important ROW elements. b. Awnings and canopies shall shade windows with the awning top mounted no more than one foot above the opening below. c. Awning and canopy overhangs shall have a minimum of nine feet clear height above the sidewalk and be minimum of four feet deep, measured from the facade. The maximum depth is to back-of-curb or the tree lawn edge, whichever is less. (subject to approval by the zoning administrator and ZRC). d. Back-lighting or internal illumination through the awning or canopy is not permitted. e. One-quarter cylinder configurations are not permitted. f. Canopies shall be mounted to the building wall and supported either from below by brackets or from above by cables or chains, or be structurally integrated with the building. Photographs are provided as illustrations of intent, with no regulatory effect. They shall not imply that every element in the image is permitted. Refer to the standards on the following page for the specific requirements of this section. [image omitted; see the official code] H. Architectural Standards: facade Composition for Large Building Frontages. 1. Intent. General and storefront frontages have additional specific design parameters to ensure that they create a positive pedestrian environment. 2. Applicability. These standards maintain a pedestrian scale, even where the buildings are quite large. They apply to the first four stories of the facade. This conservatively covers the distance within which one can discern the human face from the street. Building facades with 100 feet or more of frontage on a block face are subject to this rule. Lots with street frontage of less than 100 feet on a block face are exempt from this rule for that block face, but shall still include at least one functioning pedestrian street entry and meet all other applicable building form standards. 3. Facade composition. The facade composition rule is intended to maintain a pedestrian-friendly scale. "Facade composition" is the arrangement and proportion of facade materials and elements (windows, doors, columns, pilasters, bays). "Complete and discrete" distinguishes one part of the facade from another to give the appearance of distinct facades. a. For each block face, facades along the required building line shall present a complete and discrete vertical facade composition for the street-space, at no greater than the following average street frontage lengths: (i) Sixty feet for storefront frontages; (ii) Seventy-five feet for general frontages. These are average frontage lengths; the facade may be composed of bays of different sizes to achieve the average; uniform spacing is not required. b. Each facade composition shall include at least one functioning street entry door. c. The facade composition requirement may be satisfied by liner shops, which are shallow shops located in front of larger footprint uses such as grocery stores or parking structures. d. To achieve a complete and discrete vertical facade composition within a block face the applicant shall demonstrate that at least two of the following features that distinguish one facade composition from the next are included: (i) Different fenestration proportions of at least 20 percent in height or width or height:width ratio. (See Diagram 1.) [image omitted; see the official code] Diagram 1. Illustration of different fenestration proportions (ii) Different facade configurations, through a change in architectural features, such as facade elements, bay rhythm, cornice line, articulation, or detailing; change in the wall plane alone is insufficient. (See Diagram 2.) [image omitted; see the official code] Diagram 2. Illustration of facade configurations with a clearly different rhythm (iii) Change in wall material; color changes alone are insufficient. (iv) Change in total fenestration percentage with a minimum difference of 12 percent. Ground floor facades are not included. (v) Clearly different ground story facade composition, using framing material and fenestration proportions. I. Architectural Standards: Street Walls and Fences. 1. Purpose and intent. The street-space is physically defined by buildings, walls, or fences. Land should be clearly public or private; in the public view or private and protected. Street walls establish a clear edge to the street-space where there is no building. These requirements include masonry walls that define outdoor spaces and separate the street-space from the private realm (e.g. parking lots, gardens, trash cans, and equipment). All street wall faces should be designed as is the building facade, with the finished side out (i.e. the "better" side facing the street-space). Photographs are provided as illustrations of intent, with no regulatory effect. They shall not imply that every element in the image is permitted. Refer to the standards on the following page for the specific requirements of this section. [image omitted; see the official code] 2. Applicability. The following standards apply to all street walls and fences that are clearly visible from the street-space. 3. Materials. a. Walls. (i) Brick; (ii) Natural stone; (iii) Stucco on masonry (such as concrete block or poured concrete); (iv) A combination of materials, e.g., stone piers with brick infill panels, masonry with iron or steel. b. Gates and fenestration. (i) Metal, including wrought iron, welded steel and/or electro-plated black aluminum; may also be used for fenestration in the wall itself; or (ii) Wood. c. Dooryard and privacy fences. (i) Wood; (ii) Wrought iron or metal that faithfully imitates wrought iron; (iii) Dimensional composite material (synthetic and composite woods); or (iv) A combination of any of the above materials with masonry piers; (v) Rolled fencing (such as chain link) is prohibited where clearly visible from the street-space; (vi) Additional materials may be proposed to the zoning administrator and ZRC for review under the equivalent or better standard, see section B.2.b above. 4. Configurations and techniques. Permitted configurations and techniques (See also section 26-193, Building form standards): a. Street walls: (i) Shall be built to the height and length specified in the applicable building form standard. (ii) Taller than five feet are subject to the fenestration requirements of the applicable BFS frontage; those lower than five feet may use the fenestration parameters. b. Dooryard fences and privacy fences: (i) Shall be "finished side" facing the street or adjacent property; (ii) Dooryard fences: must be at least ⅓ open and not solid. Wooden picket boards should not be more than 3.75 inches wide and set so that the space between them is not more than three inches wide. [image omitted; see the official code] Street walls with coping and wrought iron along an unbuilt street frontage. J. Architectural Standards: Entry Features, Front Porches, Stoops and Canopies. 1. Purpose and intent. Building entries are the front door of a building and provide a connection between the building interior and the outside, public activity. They also establish a clear hierarchy and focal point for the building. Entries should be scaled appropriately to the size of the building. Photographs are provided as illustrations of intent, with no regulatory effect. They shall not imply that every element in the image is permitted. Refer to the standards on the following page for the specific requirements of this section. [image omitted; see the official code] 2. Applicability. The standards in this section apply to all building facade entries within a Character District. 3. Materials. Permitted materials for front porches, stoops, and other entry features: (For awning and canopy materials, see section G, Awnings and canopies, above.) a. Foundation walls and piers of stucco, stone, split-faced concrete, poured concrete with a smooth finish, or brick. b. Porch posts, piers, columns or pilasters of wood, or approved fiber cement product, stone, stucco, brick, or split-faced block. c. Balustrades of: wood, which must be finished (painted or stained, no raw lumber); large section aluminum; or zoning administrator approved synthetic, which must be paintable. d. Privacy lattice (max one inch openings) enclosing open foundations. e. Additional materials may be proposed to the zoning administrator and ZRC for review under the equivalent or better standard, see section B.2.b above. 4. Configurations. Entries should be distinguished by variations in facade design, materials, and articulation that clearly identifies the entrance. a. Spacing between columns, piers or posts shall be no wider than 1.33 times their height (for example, nine feet tall posts can not be more than 12 feet apart). b. All required front porches or stoops shall be roofed, with supporting posts, brackets, piers or columns and railings. Stoops may alternately have a canopy or awning covering. The awning or canopy may be supported as described in a., above, or hung from the facade by chains or wires of not less than ⅜ inches diameter. c. The minimum dimension [13] or diameter for single columns or posts is seven inches, four feet if paired/doubled, turned posts are allowed to have portions with a diameter that are as much as ⅓ below the minimum. Supporting masonry bases have a eight inch minimum dimension, and pilasters must be at least eight inches wide by one inch in depth from the facade. d. Pediments, or any other entry architectural detailing, must be at least four inches in depth from the facade and completely span the entry opening. e. Canopies must completely cover the stoop they are overhanging. f. Balusters and railings shall be a minimum dimension of one inch (maximum four inch dimension) with a maximum three inches clear space between them. They must sit on and be attached to the front porch or stoop floor/platform's top surface, they may not be attached to it's joists or the side of the platform. g. Front porches or stoops with railings/balustrades shall be at least 30 inches in height above their floor and fully surround the front porches or stoop excepting a maximum six feet wide front opening and (separate) side opening for any side access. h. Porch screen frames may only be mounted behind the columns, posts or piers and intermediate screen supports not less than three feet apart. 5. Techniques. Required front porches or stoops may be open in any direction. The elevation facing the street(s) shall not be enclosed (except by insect screening) above a level of 40 inches above the front porch or stoop floor. [image omitted; see the official code] Canopies and awnings K. Architectural Standards: Lighting and Mechanical. Photographs are provided as illustrations of intent, with no regulatory effect. They shall not imply that every element in the image is permitted. Refer to the standards on the following page for the specific requirements of this section. [image omitted; see the official code] Pedestrian-scale street lights [image omitted; see the official code] Not permitted, visible from the street-space [image omitted; see the official code] Not permitted within the street-space [image omitted; see the official code] Not permitted, visible from the street-space The illustrations above are examples of mechanical equipment arrangements that are only acceptable away from and/or not visible from a street-space (i.e. within an alley or screened from view). 1. Purpose and intent. These standards are intended to enhance the urban pedestrian context. Appropriate lighting is desirable for night-time visibility, safety, and decoration. However, lighting that is too bright or intense creates glare, hinders night vision, and creates light pollution. Restricting the location of mechanical equipment limits intrusions that would otherwise detract from the public realm. All street lights within a Character District should be pedestrian-scaled. Highway-scale, "cobra-head," fixtures are generally not appropriate for true urban contexts and should be limited to intersections where absolutely necessary. 2. Applicability. The standards in this section shall apply to all properties in a Character District. Exceptions may be made to comply with state highway standards where necessary. 3. Exterior lighting. a. Pedestrian-scale streetlights should be: (i) Coordinated by the Department of Public Works and Cedar Falls Utilities (CFU) and done in accordance with any adopted streetscape plan; (ii) Located on each side of the street-space; (See section 26-195, Public realm standards) and (iii) Coordinated with street tree placement and located at least ten feet apart from one another. b. Site and accent lighting. These standards are intended to prevent light from one property extending beyond the property line onto adjacent properties. Compliance with this subsection is achieved with fixture shielding, directional control designed into the fixture, fixture location, fixture height, fixture aim, or a combination of these methods. (i) Site lighting shall be designed to illuminate only the lot. If mounted on poles, lights shall not be mounted higher than 25 feet above grade. An exterior lighting plan shall be approved as consistent with these standards by the zoning administrator in consultation with the ZRC. (ii) Floodlighting or directional lighting is prohibited except for lighting of loading and service areas, and on civic buildings or monuments, to highlight architectural features (such as cupolas, towers, or courthouse domes) [14], and shall not produce glare into neighboring windows or light trespass into neighboring properties. Floodlights are not permitted for parking lots or outdoor display/storage areas. (iii) All under-canopy lights or lights mounted in eaves must either be recessed into the canopy/eave and fully shielded or use flat lenses instead of drop lenses. (iv) Lights within ground floor commercial space or shopfronts shall be used to illuminate the interior space and/or window displays and shall not be directed outward into the street-space. (v) Light fixtures used to illuminate flags, statues, or objects mounted on a pole or pedestal must use a narrow cone of light that does not extend beyond the illuminated object. Lights that are intended to architecturally highlight a building or its features must use a limited pattern of light that does not extend beyond the wall of the building. (vi) Floodlights, when permitted, must be aimed no higher than 45 degrees from vertical; be located and shielded such that the bulb is not directly visible from any adjacent residential use or public right-of-way. (vii) In neighborhood frontages, lighting used to illuminate outdoor private recreational facilities, such as swimming pools, tennis courts, and basketball courts, must be turned off by 10:00 p.m. Underwater lighting in swimming pools and hot tubs are exempt from this provision. (viii) No lights may exceed 0.5 initial horizontal foot-candle and 2.0 initial maximum foot-candle as measured at any point along a property boundary that is adjacent to or across the street or alley from neighborhood frontages and properties outside the Character District that are zoned residential. (ix) Exterior lights on the building shall be shielded and downcast or must be frosted glass or be installed behind a translucent cover. Exterior lights shall be maximum 100-watt incandescent or maximum 1600 lumens. Lights on the facade shall be mounted between eight feet and 12 feet above the adjacent sidewalk These fixtures shall illuminate the dooryard and clear sidewalk area. Lights on the alley shall have a 12 foot maximum height. These fixtures shall illuminate the alley and may also illuminate a portion of their own rear yard area. They shall not direct light or cause glare into neighboring lots. (x) High intensity discharge (HID) or fluorescent lights shall not be used on the exterior of buildings. (xi) Temporary holiday lighting is exempt from these regulations, in accordance with other city standards. 4. Mechanical equipment. a. All mechanical equipment located at grade (serving the building or tenant use) shall be placed behind and away from any required building line and screened by a street wall if necessary to prevent its being clearly visible from the street-space. b. All mechanical equipment on a roof shall be screened, and all screening and penthouses placed on a roof shall be set back from the roof line by a distance at least equivalent to the height of the screening or penthouse in order to minimize visibility from surrounding streets and shall have a maximum height of 18 feet. L. Architectural Standards: Signage. Photographs are provided as illustrations of intent, with no regulatory effect. They shall not imply that every element in the image is permitted. Refer to the standards on the following page for the specific requirements of this section. [image omitted; see the official code] Neon sign within the shopfront window [image omitted; see the official code] Window sign [image omitted; see the official code] Parapet sign [image omitted; see the official code] Wall sign [image omitted; see the official code] Horizontal blade sign [image omitted; see the official code] Wall sign 1. Purpose and intent. Signs in Character Districts should be scaled and designed for these mixed-use, pedestrian-oriented areas and not for high speed automobile traffic. Signage along commercial and mixed-use frontages should be durable and is desirable for both informational purposes and as decoration. Signage that is too large creates distraction, intrudes into or lessens the district experience, and creates visual clutter. 2. Applicability. The standards in this section apply to any sign that is CLEARLY VISIBLE FROM THE STREET-SPACE in the frontages designated as Urban General or Storefront, except for signs for Civic and Institutional Uses, as defined in this Chapter. Signs for Civic and Institutional Uses located in a Character District and signs in the Neighborhood Frontages are regulated according to the sign standards for the R-1 zoning district. 3. General standards for all signs. All signage shall conform to the requirements of article IV of this chapter, except as provided for below. a. Only sign types specified in this section are permitted. b. Prohibited: Billboards, roof signs, and mural signs painted on facades (except those existing prior to November 1, 2021). Mural signs are permitted, subject to approval by the zoning administrator in consultation with the ZRC, on the other exterior walls (side, rear, and courtyard elevations). c. Signs may be illuminated externally from a constant light source. Signs may not be illuminated by flashing, traveling, animated, or intermittent lighting, whether such lighting is of temporary or long-term duration. d. Internally illuminated back-lit acrylic-faced cabinet signs and plastic-faced letterform signs are not permitted. e. Signs shall not include an Electronic Message Center (EMC) unless explicitly permitted below. 4. Wall signs. [image omitted; see the official code] Wall sign within sign band a. Except for approved 1st Street exceptions, are only permitted within the sign band—the horizontal area on the facade between the first floor ceiling and the second story floor line. For one-story buildings, the sign band shall be above the windows and below the cornice. In no case shall this band be higher than 20 feet or lower than 11 feet above the adjacent sidewalk. b. Shall not exceed 20 feet in length, 90 percent of the shopfront width, nor come closer than two feet to an adjacent common lot line. c. Sign area shall not exceed one and one-half times the shopfront width. d. Shall not extend over the architectural features of the building facade, such as cornices, pilasters, transoms, window trim, and similar. e. A masonry or bronze plaque may be placed in the building's cornice or parapet wall or under the eaves, and above the upper story windows. Any such plaque shall be no larger than a rectangle of 18 square feet. [image omitted; see the official code] Masonry parapet sign 5. Projecting signs are generally perpendicular to the required building line. Projecting blade signs, marquee signs, and corner signs are permitted. a. One blade sign per shopfront is permitted. They: (i) May project from the sign band, or be hung from a ground story overhang, canopy, or awning; (ii) Shall be no more than six square feet; (iii) Shall project from the building no more than 42 inches; (iv) Shall be a minimum of eight feet clear above the sidewalk; (v) Shall be located no closer than one foot from a common lot line or adjacent shopfront space and no closer than ten feet from any adjacent blade sign; and (vi) Shall not be internally illuminated. [image omitted; see the official code] Vertical blade sign b. Marquee signs are integrated with an entry canopy. They: (i) Are only permitted with a theater use; (ii) May project to the far edge of the clear sidewalk; and (iii) May include an EMC within the sign band area. [image omitted; see the official code] Marquee sign c. Corner signs that are visible from two or more intersecting streets are permitted as long as: (i) There is no more than one per block corner; (ii) They are located above the ground story sign band and below the third story, or for a two-story building below the cornice line; (iii) They do not exceed 40 square feet per sign face; and (iv) The maximum projection from the corner is five feet. [image omitted; see the official code] Corner sign 6. Window signs. a. Windows are measured as glass area including muntins and similar framing elements with a dimension of less than one inch. Glazing separated by framing elements of greater than one inch are considered separate windows. b. No more than 25 percent of any ground story window may be covered by signage, and such signage shall not be placed or adhered to the window in a manner that prevents views into the shopfront. c. Neon signs are allowed within shopfront windows. d. No more than ten percent of any upper story window may be covered with signs. 7. Other signs. a. Temporary sandwich board signs of up to 36 inches in height are permitted within the dooryard area. They may also be considered a permitted encroachment to the sidewalk or right-of-way, with prior approval from the city. b. Awning signs are permitted. Sign copy on awnings shall be limited to six inches in height on the outside edge/vertical face of the awning. [image omitted; see the official code] Awning sign [image omitted; see the official code] Awning signs and wall signs c. Canopy signs (not including marquee signs, which are regulated separately) are allowed on the canopy face or mounted upright along the top of the canopy with the bottom of the sign no more than four inches above the canopy. Canopy signs shall extend no more than 90 percent of the length of the canopy and be no more than 20 inches in height. Signs mounted on the face of a canopy must maintain a minimum of three inches spacing between the sign and the top and bottom of the canopy face. No more than one canopy sign is allowed per shopfront and a canopy sign is not allowed on a shopfront that has a marquee sign. d. Directional signage as defined in this chapter is allowed for assisting traffic flow through allowed drive-through facilities. 8. Freestanding signs. a. No new freestanding signs are permitted after November 1, 2021. b. Any property owner voluntarily removing a legally non-conforming freestanding sign may be allowed a bonus of up to 150 percent of the building signs allocated to the property. For example, if a property is allocated 40 square feet of building signs, the property may be allowed 60 square feet of buildings signs if a legally nonconforming freestanding sign is removed. c. Bonus signage will still be required to meet the specific placement standards for the particular sign type(s) requested. 9. First street exceptions for multi-story buildings in the Urban General and storefront frontages. An additional wall sign is permitted in a sign band located above the top story windows and below the cornice that has: a. Square footage less than or equal to one and one-half times the length of the sign wall; and b. Length no greater than 90 percent of the length of the sign wall.
(Ord. No. 2994, § 9(Att. A), 11-1-2021; Ord. No. 3027, § 1, 5-25-2023; Ord. No. 3032, § 1, 8-7-2023)
Ask a question about Cedar Falls law
Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.
