For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 26-193.4 — Neighborhood medium frontage

Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 26-193.4

Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/08677971-b092-4ed3-81ab-6704004ab363

Sec. 26-193.4. - Neighborhood medium frontage.

A. Illustrations and intent. The neighborhood medium frontage is designed to fit comfortably into an existing neighborhood context, allowing redevelopment with a slightly increased scale and intensity. This frontage allows attached dwellings (rowhouses, duplexes), detached houses, cottage courts, and/or small apartment buildings. The character and intensity of this frontage varies depending on the scale of its context. These frontages generally have rear yards and parking accessed from an alley. Note: These photos and statements are provided as illustrations of intent and are advisory only. They are not regulatory. Refer to the standards on the following pages for the specific standards of the neighborhood medium building form standard. [image omitted; see the official code] B. Example Building Placement Configurations. Note: These diagrams illustrate some of the building configurations possible under the placement standards on the following page. They do not represent fully designed buildings nor do they address issues such as parking or the International Building Code. Refer to the following pages for the specific standards of the neighborhood building form standards. [image omitted; see the official code] These diagrams, aligned above the placement diagram from the standards on the following pages, illustrate a few of the possible configurations a building can take under the neighborhood medium and neighborhood small building form standards. The green area represents the required private open area. Diagram 1 shows a detached house, single-unit or two-unit. The area at the rear of the lot shows a two-story building—a garage with an accessory dwelling unit or extra room above it. There could be a sidewing connecting the garage to the main house. The house has its own side and rear yards providing the required private open area. Diagram 2 is a set of three rowhouses. The buildings may be attached single-family units, with each unit on a separate lot, or they may by a multi-unit building on a single lot. The area at the rear of each rowhouse has two ground level parking spaces with an accessory dwelling unit (ADU) or extra room above the garage. Each rowhouse has a dooryard, with its private open area provide by a rear yard and rear terrace. Diagram 3 represents a small apartment building. The building has sidewings that project into the rear yard of the building. The rear of the lot has a parking shed, accessed from the alley. The green area between the parking shed and the main building satisfies the private open area requirement. Diagram 4 is a small apartment building on one lot. The building is likely configured as a "double-loaded corridor" building with units facing the street or the rear yard. The green area behind the main building satisfies the private open area requirement with a shared yard. A surface parking lot is accessed from the alley. Diagram 5 is a re-oriented placement diagram for the neighborhood frontages, provided for reference. The red dashed line is the required building line, the blue dashed line is the parking setback line, the gray area is the buildable area, and the green rectangle within it represents the private open area. This is more fully explained in the frontage standard itself, located on the following pages. [image omitted; see the official code] C. Placement. 1. Facade. On each lot the building facade shall be built to the required building line (RBL) for at least 66 percent of the RBL length. 2. A street wall or privacy fence is permitted on any unbuilt required building line. 3. Maximum facade width. No individual structure or attached set/group of rowhouses may exceed a maximum facade frontage length of 80 feet. A gap of at least ten feet is required between each building or set of rowhouses. 4. Buildable area. a. The buildable area is delineated by the gray area in the diagram above. The main portion of the buildable area is within 60 feet of the RBL. The sidewing buildable areas are between the main and rear buildable areas and within 20 feet of each side setback. b. The required building line is indicated on the regulating plan. It is generally located 15 feet off the ROW/property line for neighborhood medium. The exact position of the RBL should be confirmed in consultation with the zoning administrator and ZRC. c. Setbacks: Five feet each side lot line [5]; three feet from an alley and 11 feet from rear lot line where there is no alley. d. A private open area equal to at least 20 percent of the buildable area must be provided on every lot. i. The minimum private open area dimension is 18 feet. ii. The private open area must be located at least 30 feet behind the required building line. iii. The private open area must be at grade, except balconies and extremely shallow lots, as specified in v. below; iv. Up to 33 percent of the required private open area may be satisfied through the balconies of individual rowhouses and/or units, which are exempt from i and ii above. v. The private open area for lots with less than 70 feet from the required building line to the rear setback, may be above grade. 5. Other. a. The parking setback line is indicated on the regulating plan, generally 40 feet from the rear lot line, with limited exceptions at alley/RBL intersections and for other special conditions, see F.3, Rear lot area, below. The side setback for parking is three feet from any common lot line. b. The minimum rowhouse width, measured parallel to the RBL, is 18 feet. c. A privacy fence is permitted, at or behind the required building line, on common lot lines, and on rear lot lines. [image omitted; see the official code] D. Height. 1. Building height: a. At and within 60 feet of the RBL: Minimum 15 feet at RBL, maximum three stories and 36 feet. b. Sidewing and rear lot area: maximum 18 feet. 2. Ground floor finished elevation: Within 30 feet of the required building line, three feet to five feet. Entrances may be at grade, with transitions to meet the minimum finished floor elevation within the building interior. This this does not prohibit an accessory unit in an English basement form. 3. All stories clear height: Nine feet minimum. 4. Street wall: Permitted, four feet to eight feet. 5. Dooryard wall or fence: permitted, maximum 40 inches. This is an optional low garden wall or fence surrounding the dooryard area. See section 26-194, Architectural standards, I, Street walls and fences. 6. Privacy fence: Permitted, six feet maximum, measured from adjacent grade. [image omitted; see the official code] E. Elements. [6] 1. Fenestration, all stories: Twenty-five to 70 percent. 2. A stoop or front porch [7] is required: a. Front porch: Minimum width ten feet, minimum depth eight feet. b. Stoop: For small apartments, width ten feet to 15 feet, depth six feet to eight feet; for all others, width four feet to six feet, depth three feet to five feet. c. For rowhouse or duplex configurations this requirement applies to each rowhouse or to each unit for a duplex. 3. Balconies: Required on the upper stories of small apartments with more than 45 feet of frontage width. Rowhouses are not subject to this requirement. Where used to satisfy this requirement, or as part of the private open area calculation, the below dimensions are required: a. Balconies shall cumulatively be a minimum ⅓ rd the facade width for each upper story. b. Minimum depth five feet, minimum width seven feet. 4. Attic story: permitted within the parameters of section 26-194.D. 5. Facade entries: All dwellings must have at least one entry in the facade that provides direct access to the street-space, whether through a shared lobby or their own entry door. ADUs are exempt but must have a clear access to the street-space. 6. Upper story access: Unenclosed or partially enclosed exterior staircases may not be used to access upper story dwelling units. [image omitted; see the official code] F. Uses. See section 26-197, Building functions, for specific parameters and/or performance standards. 1. All stories: Residential. 2. Accessory dwelling units: Permitted for single-unit dwellings. (See 193.1, General standards, G, Accessory dwelling units, above.) 3. Rear lot area: a. In addition to the residential use, parking and loading is permitted, behind the parking setback line. b. For lots with an alley/required building line intersection, where there is an additional parking area designated on the regulating plan, parking is permitted in this area when: i. It is within a building; ii. The facade of the building enclosing the parking meets all requirements; iii. It is two feet off the front of the required building line; and iv. Within 40 feet of the rear lot line. c. See also additional parking location exceptions specified in [section] 26.193.1A.6.

(Ord. No. 2994, § 9(Att. A), 11-1-2021; Ord. No. 3041, § 3, 9-18-2023; Ord. No. 3126, § 3, 11-3-2025)

Ask a question about Cedar Falls law

Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.