34.34 - Rule for Computing Range and Dwelling Loads.
Branch Circuit Requirements: One circuit for lighting shall be provided for every 600 square feet of finished floor space, or space which may be finished. In addition, provision for the following appliance circuits shall be made: Two separate 20-ampere circuits for kitchen and breakfast area receptacles. The garbage disposal unit may be wired on one of the kitchen receptacle circuits or the dishwasher circuit. There must be at least two circuits on the main usable counter top area. One separate 20-ampere circuit for each laundry area. Other circuits, if installed, shall be as follows: • One separate 20-ampere circuit for microwave oven. • One separate circuit for each no gravity furnace with disconnect switch. • One separate 20-ampere circuit for each food freezer. • One separate 20-ampere circuit for each dishwasher. • One separate 20-ampere circuit for a workshop. • One separate 20-ampere circuit for a refrigerator. • One separate 20-ampere circuit for a garage. • Additional separate circuits for other heavy loads. (040-25)