34.38 - Wiring Methods—Dwellings.

Habitable space. Non-metallic sheathed cable may be installed for conductors in the concealed wood or steel frame portions of one and two-family dwellings, or multi-family buildings and accessory structures to said buildings. Non-metallic sheathed cable is prohibited in any occupancy classifications other than R-2, R-3 or R-4 unless protected by rigid metal conduit, intermediate metal conduit. Electrical metallic tubing or schedule 80 PVC conduit. The residential part(s) of group homes may be wired in non-metallic sheathed cable if the occupant load is not more than twenty persons. Habitable spaces in accessory buildings do not need ground fault protection for outlets. Electric panels shall not be installed within six inches of the corner in an unfinished basement in new construction. Basements and garages. In all unfinished basements and attached/detached garages, non-metallic sheathed cable running horizontally shall be protected from a height of 7 feet and below by EMT, other approved conduit or drywall. Required Basement Lights. A lighting outlet with lamp-holder shall be provided in each room of a basement or cellar of a residential building. At least one such fixture shall be located in every 200 square feet of such floor space. Circuits. No connection shall be made between the basements or cellar wiring and the wiring in the floors above except as provided in this Section. Exceptions: Basement or cellar wiring in a single-family dwelling may be fed by grounded nonmetallic sheathed cable from the floor above if the entrance panel is not located inside the basement or cellar. The lighting outlet with lamp-holder at the bottom of the basement or cellar stairs may be fed from either the first floor or basement. When rewiring, the circuits may be fed from the basement. It is permissible to wire the smoke detectors from either the basement circuit or a circuit from the floor(s) above. It is permissible to wire basement appliance circuits through the floor(s) above. (040-25)

Ask a question about Cedar Rapids law

Corpus searches the Cedar Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.