15.44.130. - Construction standards.

In all Areas of Special Flood Hazard, the following provisions are required: A. New Construction and Substantial Improvements of an Existing Structure, including a Structure that has been substantially damaged, must be anchored to prevent flotation, collapse, or lateral movement of the Structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. B. New Construction and Substantial Improvements of an Existing Structure, including a Structure that has been substantially damaged, must be constructed with materials and utility equipment resistant to Flood damage. C. New Construction or Substantial Improvements of an Existing Structure, including a Structure that has been substantially damaged, must be constructed by methods and practices that minimize Flood damage. D. All New Construction or Substantial Improvements of an Existing Structure, including a Structure that has been substantially damaged, including the fully enclosed area located below the Lowest Floor formed by the foundation and other exterior walls, must be designed to be an unfinished or Flood resistant Enclosure. This includes the foundation walls used to elevate the Building and any joists, insulation, or other materials that extend below the BFE. The Enclosure must be designed to equalize hydrostatic Flood forces on exterior walls by allowing floodwater's automatic entry and exit. Designs for complying with this requirement must be certified by a licensed professional engineer or architect or meet the following minimum criteria: 1. Provide a minimum of two (2) openings meeting the following criteria: a. A total net area of not less than one square inch for every square foot of enclosed area subject to Flooding; b. The bottom of all openings must be no higher than one foot above the higher of the exterior or interior grade or floor immediately below the opening; and c. Openings should be installed in at least two (2) walls and may be equipped with screens, louvers, valves, or other coverings or devices, provided they permit the automatic flow of floodwater in both directions without manual intervention. 2. The velocity of floodwaters at the site should not exceed five (5) feet be second unless the design is certified explicitly by a licensed professional engineer or architect. 3. To comply with this chapter's "Lowest Floor" criteria, the unfinished or Flood resistant Enclosure must only be used for parking vehicles, limited storage, or entry to the elevated area. 4. The interior portion of such an enclosed area must not be partitioned or finished into separate rooms. 5. For below-grade crawl spaces, construction must follow the guidelines in FEMA TB 11-01, crawl space construction for Structures located in Special Flood Hazard Areas: National Flood Insurance Program interim guidance, specifically: a. The interior grade of a crawl space below the BFE must not be more than two (2) feet below the Lowest Adjacent Grade (LAG); b. The height of a below-grade crawl space, measured from the lowest interior grade of the crawl space to the bottom of the floor joist, must not exceed four (4) feet at any point; and c. Below-grade crawl spaces must contain an adequate drainage system that removes floodwaters from the interior area of the crawl space within a reasonable time after a Flood event. d. Below-grade crawl spaces are prohibited at sites where the velocity of floodwaters exceeds five (5) feet per second. E. All heating and air conditioning equipment and components, all electrical, ventilation, plumbing, and other facilities must be designed or elevated to prevent water from entering or accumulating within the components during Flooding. F. New and replacement water supply systems must be designed to minimize or eliminate infiltration of floodwaters. G. New and replacement sanitary sewage systems must be designed to minimize or eliminate infiltration of floodwaters and discharges from the systems into floodwaters. H. On-site waste disposal systems must be located and constructed to avoid functional impairment, or contamination from them, during Flooding. I. Any alteration, repair, reconstruction, or improvement to a Structure that is not compliant with the provisions of this chapter, may only be undertaken if the nonconformity is minimal to meet health and safety standards.

(Ord. No. 1494, § 1, 9-19-2023)

Ask a question about Post Falls law

Corpus searches the Post Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.