Sec. 29.5-4.13. - Drainage system design and evaluation.

The following criteria should be used in evaluating and designing the drainage system. The underlying objective is to provide capacity to pass the 5-year peak flow in the minor drainage system and an overload flow path for flows in excess of the 5-year peak flow. (a) Design methodologies - Detention basins. Runoff hydrograph methods as described in the Manual must be used for the design of all detention basins. (b) Design methodologies - Minor conveyances. Minor conveyance systems including storm sewers shall be designed using acceptable methods described in the Manual. (c) Design methodologies - Major conveyances. Major conveyance systems can be designed using flows calculated using acceptable methods described in the Manual. (d) Positive drainage. All areas of the property must be provided an overland flow path that will pass the 100-year flow at a stage of at least one foot below the lowest foundation grade in the vicinity of the flow path. Overland flow paths designed to handle flows in excess of the minor drainage system capacity shall be designed to pass the overland flow to the appropriate receiving detention basin, or in the absence thereof, to the appropriate receiving drainage facility. (e) Unobstructed storm sewer outlets. Storm sewers from new subdivisions must outlet in unsurcharged condition in a 5-year storm event or be provided with pumping equivalent to same. (f) Minimum slope requirements. Runoff from overland drainage shall be collected into and conveyed to approved facilities by a variety of systems including swales, ditches, streets, underdrains, storm sewer conduits and open channels. Gradients for each such conveyance component are critical for proper functioning. Minimum, and where appropriate, maximum slopes for each type of drainage facility and material are listed in the Manual.

(C.B. No. 97-265, § 1, 10-7-97)

Ask a question about Champaign law

Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.