Sec. 18-169. - Tank storage of inflammable liquids either above or below ground.
The storage of inflammable liquids, hereinabove described as Classes I, II and III, where stored in tanks in storage plant as above defined, shall be in accordance with the following regulations. (a) Property regulations. No storage tank shall be less than three hundred feet from any schoolhouse, church, hospital or public hall. The distance shall be measured from the near edge of tanks in all directions to the near point of building. A public hall shall be defined as any building used for the assembling of people for amusement, instruction or religious worship. (b) Property lines and buildings. The minimum distance from individual tanks to line of adjoining property which is or may be built upon, shall not be less than the following: Tanks of three thousand gallons or less, twenty feet; tanks of from three thousand to twenty-one thousand gallons capacity, twenty-five feet; tanks of from twenty-one thousand to thirty-one thousand gallons capacity, thirty feet; tanks of over thirty-one thousand gallons capacity, fifty feet. When general tank storage is maintained in connection with a filling station, the distance from the general storage tanks to the filling station building, tanks and equipment shall be the same as that required to property lines. (c) Distance between tanks. The minimum distance from tanks to adjacent tanks shall be as follows: Tanks of a capacity of less than eighteen thousand gallons, three feet from any adjoining tank: tanks of eighteen thousand gallons capacity or more, five feet from any adjoining tank. If tanks are of different capacities, the capacity of the larger tank shall govern its distance to adjacent tanks. (d) High water. Tanks shall be located so as to avoid possible danger from high water. (e) Specifications. All tanks shall meet specifications of the Underwriters' Laboratories and no open tanks shall be permitted. All tanks shall be covered with asphaltum or other non-rusting coating. All pipe connections shall be made through flanges or reinforcements securely riveted, welded or bolted to the tank. All openings shall be made liquid and vapor tight, except breather vents. Gaskets used shall be such as are not affected by heat or the contents of tanks. Covers for manholes, handholes and gauge holes shall be made tight fitting and kept in place when said opening is not in use. (f) Venting of tanks. Each tank over one hundred gallons in capacity shall have vent openings, except safety valves, provided with approved non-corrodible flame arresters so attached as completely to cover the openings, and such openings shall in no case be less than one and one-fourth inches in diameter and where a power pump is used in filling tanks and a tight connection is made to fill pipe, vent shall not be smaller than pipe. Additional vent openings or safety valves adequate to relieve any excessive pressure due to external heat shall be provided and the same shall be self closing when pressure is relieved. The total area of vents shall be not less than twenty-four square inches for tanks having a capacity up to twenty-one thousand gallons and seventy-eight square inches for tanks of larger capacity. (g) Installation of tanks. Tanks constructed more than one foot above ground shall have a firm foundation and supports of non-combustible materials with bases below the frost line. Unprotected steel as a support for tanks is prohibited. No combustible materials shall be permitted under or within ten feet of any storage tanks except stairways to and walks on top, and these preferably to be of iron or steel. All tanks shall be grounded electrically and effectively to permanent moisture. (h) Piping. All piping shall be standard full weight wrought iron or steel at least one-half inch internal diameter and tested to working pressure of one hundred pounds with suitable allowance for expansion and contraction. Above ground piping shall be protected against mechanical injury, and underground piping shall not be surrounded with any material of corrosive effect, and where carried in conduit, the openings of the conduit must be fully protected to prevent escape of liquid. All underground piping shall be coated with asphaltum or other corrosion resisting material. Joints may be welded or of ordinary screw type, but if screw type is used, they shall be made with litharge and glycerine, lamp black or shellac and shall be tested for thirty minutes at a pressure fifty per cent in excess of working pressure. Each pipe attached to a tank shall be provided with a valve at the tank, with no branches between the tank and valve, and in case two or more tanks are cross-connected, there shall be a valve at each tank in each cross-connection. Tanks with different classes of liquids shall not be cross-connected. In addition to normal valve, there shall be an extra valve at each pipe line, installed on the inside of the tank and operated by an effective heat releasing device, which will automatically prevent the flow of liquid from the tank in case of fire, even if pipe lines are broken from the tank. (i) Embankments and dikes. Above ground tanks shall be surrounded with a liquid tight embankment or dike of poured reinforced concrete or brick sufficiently reinforced and with sufficient footing below frost line to withstand pressure of liquid if filled to capacity; provided, that the city building inspector before issuing any permits for said structure may require that the plans and specifications submitted shall be approved by a licensed structural engineer certifying as to the sufficiency of the structure to conform to said provision. Such dikes shall have a capacity of not less than one and one-quarter times the capacity of the tanks within it, and shall be at least four feet high; but in no case higher than one-half the height of the highest tank located within the enclosure. Embankments or dikes shall be continuous with no openings for piping or roadways. At points where it is necessary to pass over the embankments, properly built brick or concrete steps or concrete roadways shall be provided. (j) Buildings. The distances of tanks from property lines and buildings as prescribed in section 18-169(b) hereof shall apply to any buildings used by licensee except oil warehouses, pump houses and garages each of which shall be located in separate noncombustible buildings, and said pump house shall be not less than ten feet from said tanks. Motors used in pump houses shall be of polyphase, non-sparking or explosive-proof type, and shall be grounded permanently to moist earth. Any of said buildings which are electrically lighted shall have lights of vapor proof type, the wiring of which shall be in sealed conduit and switches for motors and lights shall be placed outside of the building or shall be of the explosion-proof or oil bath type. In the pump house, screen openings of not less than sixty-four square inches shall be constructed in opposite corners at the floor line to provide proper ventilation. Floors of said building shall be of concrete or non-combustible material, and all buildings shall be kept neat, clean and free from refuse, grease or oil spillage. No liquid of Class I or II shall be stored in any of these buildings and there shall be no connection from any of said buildings to any house drainage or sewer system unless an adequate grease trap is provided ahead of such connection. This shall not apply to lavatories, toilets or wash basins, used exclusively for toilets or personal use, nor to down spouts carrying surface water from the roof. (k) Unloading and loading. No liquids of Classes I and II shall be withdrawn from tank cars through bottom outlets, but only through the dome of said tank car, and pumps used shall be securely installed to prevent leakage. The use of compressed air to discharge contents of tank car is prohibited, as is the unloading from tank cars to trucks or other portable containers. Tank cars shall not be left connected to pipe lines except when loading or unloading takes place and during all such times some qualified person shall be near and in supervision. No flame, lanterns, flame switch lights, or other exposed flame lights shall be exposed during the process of loading or unloading. Before loading or unloading process begins, tank trucks shall be electrically bonded to pipe lines by means of an electrical device at the loading dock. (l) Property protection. The area embracing the tank yard, including dikes and all above ground pipe lines, shall be properly fenced to exclude intruders, and said yard shall be kept free from weeds, high grass, rubbish and litter, and no open lights or flames shall be permitted on the property. Approved chemical fire extinguishers, foam generators, or other smothering agents for extinguishing oil fires shall be provided.
(Ord. No. 5502, § 4, 7-7-70)
Ask a question about Joliet law
Corpus searches the Joliet sections it holds and shows the ones that match, with their citations. Free, no sign-in.