§ 18-174 — Tank and pipe requirements

Code of Ordinances, City of Joliet, Illinois (Supp. No. 201: codified through Ordinance No. 18888, enacted September 1, 2026) · Joliet City Code § 18-174

Corpus is an independent public-information project, not the official City of Joliet website. Stable reference: corpuslaw.us/code/2b3f4625-382a-4735-b942-1710126798aa

Sec. 18-174. - Tank and pipe requirements.

Tanks shall bear label of Underwriters' Laboratories or meet equivalent specifications. (a) Tanks shall be thoroughly coated on the outside with tar, asphaltum or other suitable rust-resisting material. (b) Tanks shall not be surrounded or covered by cinders or other material of corrosive effect. If the soil contains corrosive material, special protection shall be provided. (c) Each tank shall be provided with a vent pipe, connected with the top of the tank and carried up to the outer air. Pipe shall be arranged for proper draining to storage tank, and its lower end shall not extend through top of tank for a distance of more than one foot; it shall have no traps or pockets. (d) Upper end of pipe shall be provided with a gooseneck or T attachment, or weatherproof hood. (e) Vent pipe shall be of sufficient cross-sectional area to permit escape of air and gas during the filling operations, and in no case less than one inch in diameter. If a power pump is used in filling storage tanks, and a tight connection is made to the fill pipe, the vent pipe shall not be smaller than the fill pipe. (f) Vent pipe shall terminate above the outside of building not less than twelve feet above top of fill pipe, not less than four feet measured vertically and horizontally, from any window or other building opening, and not less than fifteen feet measured horizontally from any opening into the basement, cellar or pit of any building, and in a location which will not permit pocketing of gas. If a tight connection is made in the filling line, the terminus of vent pipe shall be carried to a point one foot above the level of the highest reservoir from which tank may be filled. (g) Vent pipes from two or more tanks of the same class of liquid may be connected to one upright or main header. Area of header shall equal the combined area of the pipes connected to it. Connection to the header shall not be less than one foot above the level of the top of the highest reservoir from which tanks may be filled.

(Ord. No. 5502, § 9, 7-7-70)

Ask a question about Joliet law

Corpus searches the Joliet sections it holds and shows the ones that match, with their citations. Free, no sign-in.