§ 8-28 — International Residential Code
Code of Ordinances of the Village of Palatine, Illinois (Codified through Ordinance No. O-113-26, enacted October 12, 2026. (Supp. No. 2, Update 2)) · Palatine Code of Ordinances § 8-28
Corpus is an independent public-information project, not the official City of Palatine website. Stable reference: corpuslaw.us/code/1ca7ce8e-6f29-4bb5-8fe7-ea9392c85b31
Sec. 8-28. - International Residential Code.
The International Residential Code, 2021 edition, is hereby adopted with the following amendments: (1) Board of appeals. Section R112.0 shall be deleted. (2) Design documents. Section R106 shall be amended to create the following subsections: R106.6, designer. The International Residential Code as a prescriptive code does not provide provisions on alternative construction methodologies. The use of these alternative construction methodologies, including, but not limited to, structural design, shear wall designs, shall require a licensed design professional. R106.7, incomplete or design documents found to be insufficient. Submittals that are found to be lacking and not adequately addressing all major components of the design (structural, building, electrical, mechanical, plumbing) can be determined to be incomplete or insufficient. Once deemed incomplete or insufficient, the building official may request the applicant hire a design professional to provide guidance prior to resubmittal. (3) Climatic and geographical design criteria. Table R301.2(1) shall be amended to add the following: Table 301.2. Climatic and Geographic Design Criteria Ground Snow Load | Wind Design | Seismic Design Category | Subject to Damage From | Ice Barrier Underlayment Required | Flood Hazard | Air Freezing Index | Mean Annual Temp Speed (mph) | Topographic Effects | Special Wind Region | Windborne Debris Zone | Weathering | Frost Line Depth | Termite 30 | 115 | No | No | No | Severe | 42" | Severe | Yes | See maps | 2,000 | 50 Manual J Design Criteria Elevation | Altitude Correction Factor | Coincident Wet Bulb | Indoor Winter Design Dry-Bulb Temperature | Indoor Winter Design Dry-Bulb Temperature | Outdoor Winter Design Dry-Bulb Temperature | Heating Temperature Difference 653 | 1 | 73 | 70 | 70 | 2 | 68 Latitude | Daily Range | Indoor Summer Design Relative Humidity | Summer Design Gains | Indoor Summer Design Dry-Bulb Temperature | Outdoor Summer Design Dry-Bulb Temperature | Cooling Temperature Difference 42 | M | 50 | 36 | 75 | 90 | 14 (4) Garages and carports. Section R302.5.1 shall be amended to add: "The door shall have a hinge-type self-closer. Any attic access scuttle located in a garage ceiling, where such garage attic space is contiguous to the main dwelling attic, shall have a minimum 20-minute fire-rating label." (5) Fire-resistant construction. a. Section R302 shall be amended as follows: Delete footnote a. in table R302.1(1) and footnote b. in table R302.1(2). b. Automatic fire sprinkler systems. Section R313 shall be amended to add the following subsections: R313.3, garage sprinkler protection. Fire sprinkler protection shall be provided within attached garages at a density of 0.05 gpm per square foot. If complete coverage of the garage cannot be achieved with extended coverage dry sidewall sprinklers from the dwelling unit garage separation wall, the best achievable coverage shall be provided along with a narrative of what the limiting factors are to providing complete coverage. R313.5, notification. Exterior audio visual notification which is triggered by the fire sprinkler system shall be provided on the street side of the building unless otherwise approved by the fire official. (6) Wood foundations and pressure preservative treated wood floors (on ground). Wood foundations are not permitted. Therefore, section R402.1, all references to wood foundations in section R403, R404.2 through R404.2.6, R405.2 through R405.2.3, R406.3 through R406.3.4, and R504 shall be deleted. (7) Concrete floors (on ground). a. Section R506.1 shall be amended to read as follows: Generally. Concrete slab-on-ground floors shall be a minimum of four inches thick except as otherwise noted below (for expansive soils, see section R403.1.8): 1. Walks and patios. Public concrete walks shall be constructed with at least five inches of concrete and private walks and patios shall be constructed with at least four inches of concrete. Wire mesh is not allowed in the public walk area. 2. Driveway. Concrete driveways shall be constructed with at least five inches of concrete and concrete driveway aprons in the village right-of-way (parkway) shall be constructed with at least five inches of concrete. Wire mesh is not allowed in the parkway (apron). 3. Garage floor. Garage floors shall be constructed with at least four inches of concrete. Install a thickened concrete edge at overhead door 14 inches down and 20 inches wide. This 14-inch measurement includes the four inches for the concrete floor. Install two No. 5 five-eighths-inch diameter rebar approximately in bottom of thickened edge at overhead door approximately three inches from bottom along the full length. b. Section R506.2.2 shall be amended to read as follows: Base. A four-inch thick base course of clean graded compacted gravel or crushed stone material shall be placed on the prepared subgrade. (8) Duct construction. Section M1601.1.1, numbers 5 and 7 shall be substituted with the following: (5) Gypsum products shall not be used as ducts or plenums. (7) Wood floor joist and stud spaces shall not be used to convey conditioned supply air or return air in forced air heating/cooling systems. (9) Smoke alarm power source. Section R314.6 shall be amended to add: "Smoke alarms shall not be connected to a dedicated circuit." (10) Exterior decks. Section R507.9.2 shall be amended to add: When the deck floor height is less than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the deck, lateral load connections are not required. (11) Plumbing. Delete part VII, plumbing that contains chapters 25—33, and refer to the current edition of the Illinois Plumbing Code. (12) Electrical. Delete part VIII, electrical, that contains chapters 34—43, and refer to the National Electrical Code (NFPA 70).
(Code 1976, § 6-2; Ord. No. O-69-11, § 1, 6-20-2011, eff. 7-18-2011; Ord. No. O-21-15, 3-16-2015; Ord. No. O-93-18, 8-13-2018, eff. 1-1-2019; Ord. No. O-111-24, exh. A(6-2), 12-2-2024; Ord. No. O-47-25, § 1(Exh. A), 5-19-2025; Ord. No. O-95-26, § 1(Exh. A), 9-14-2026)
Ask a question about Palatine law
Corpus searches the Palatine sections it holds and shows the ones that match, with their citations. Free, no sign-in.
