§ 8-30 — National Electrical Code
Code of Ordinances of the Village of Palatine, Illinois (Codified through Ordinance No. O-113-26, enacted October 12, 2026. (Supp. No. 2, Update 2)) · Palatine Code of Ordinances § 8-30
Corpus is an independent public-information project, not the official City of Palatine website. Stable reference: corpuslaw.us/code/09f7ae11-d8de-4e0b-9640-953451b03f77
Sec. 8-30. - National Electrical Code.
NFPA 70 National Electrical Code, 2020 edition, is hereby adopted with the following amendments: (1) Article 210—Branch circuits. Table 210-21(B)(3), receptacle ratings for various size circuits, shall be amended as follows: "Receptacle rating for a 20 ampere circuit rating shall be 20 amperes." (2) Garages. Section 210-52(g) shall be amended to add the following: (1) In addition to the receptacle required by section 210-52, a minimum of one duplex receptacle outlet shall be installed in the ceiling of all garages in the immediate area of and for the purpose of providing electrical means for automatic garage door opening device. (2) All detached garages shall have a three-way switch arrangement from the dwelling to a light fixture outside the garage service door. (3) Services. a. Section 230.50, Service-entrance conductors protection shall be amended as follows: Delete sections 230.50(B)(1)(3) Schedule 80 PVC, 230.50(B)(1)(4) EMT, 230.50(B)(1)(5) RTRC. b. Add the following exceptions: Exception 1. In temporary services flexible metal conduit and liquid-tight metal conduit may be used for necessary flexibility at the termination of conduit runs in lengths six feet or less, where approved by the authority having jurisdiction. Exception 2. Service entrance conductors shall be allowed in rigid nonmetallic conduit underground, where covered in not less than two inches of concrete. c. Section 230.9(A), clearances, the reference to "three feet" shall be replaced with "five feet." (4) Article 240—Overcurrent protection. Add the following: All circuit breakers used for commercial and/or industrial building types shall be bolt-on type. (5) Wiring methods. Section 300.1, Scope, shall be amended to add the following: (a) All conductors within a structure or building that may carry electrical current rated at 50 volts or greater shall be installed in rigid heavy-wall galvanized steel conduit, intermediate metallic conduit, or electrical metallic tubing except as otherwise herein stated. (b) All conduit systems that are installed outside of a building or structure and exposed to any type of weather conditions and/or in contact with the earth shall be rigid heavy-wall galvanized steel conduit, unless hereinafter stated. Exception 1. Rigid nonmetallic conduit may be permitted for installations only in areas such as below concrete slabs or in locations where conduit systems will be in contact with the earth. Exception 2. Rigid nonmetallic conduit shall not be less than Schedule 40 unless approved by special permission. (6) Conductors for general wiring. Section 310.106(B), Conductor material shall be amended to read as follows: Only copper conductors shall be used for all residential and commercial branch circuits, from the load side of the metering device to the main service disconnect, for all feeder panels, service entrance conductors, neutral conductors, and the like. Exception: Compressed aluminum wire shall be allowed for service entrance conductors and feeders in commercial, nonresidential applications. Compressed aluminum wire shall be limited to number 2 or larger in size and series AA-8000 type electrical grade aluminum alloy conductor material only. (7) Water meter wiring. In all new construction, electrical metallic tubing shall be installed from the water meter location to an outside wall at a point approved by the building inspector for low-voltage wiring to a remote reader for the water meter. This shall be in place at the time of rough inspections. (8) Deleted articles. The following articles in NFPA 70, 2017 edition, shall be deleted: a. Article 398, open wiring on insulators. b. Article 396, messenger support wiring. c. Article 394, concealed knob and tube wiring. d. Article 332, mineral-insulated, metal-sheathed cable. e. Article 362, electrical nonmetallic tubing except herein stated. f. Article 334, nonmetallic sheathed cable. g. Article 338, service entrance cable. h. Article 352, sections 352.10(A) and 352.10(F) (9) Accessory building power. Accessory buildings and structures to one- and two-family homes, townhouses, and duplexes that are built to the International Residential Code shall only be served power by the primary residence unless approved by the building official.
(Code 1976, § 6-4; Ord. No. O-69-11, § 1, 6-20-2011, eff. 7-18-2011; Ord. No. O-60-14, § 1, 5-12-2014; Ord. No. O-93-18, 8-13-2018, eff. 1-1-2019; Ord. No. O-111-24, exh. A(6-4), 12-2-2024)
Ask a question about Palatine law
Corpus searches the Palatine sections it holds and shows the ones that match, with their citations. Free, no sign-in.