Section E3902.2 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows: E3902.2 Garage and Accessory Building Receptacles. 125-volt, single-phase, 15- and 20-amphere receptacles installed in garages and grade-level portions of unfinished accessory buildings used for storage or work areas shall have ground-fault circuit-interrupter protection for personnel. [210.8(A)(2)]. Exception: A dedicated receptacle supplying a garage door opener, fire alarm, security system, sump pump, refrigerator, freezer or electric vehicle charger. (History: Ord. BC-3286 §84, 2020; Ord. BC-2936 §57, 2012) Effective on: 1/1/1901