§ 16.110.N1103.3.3
Code of the City of Overland Park, Kansas · Overland Park Municipal Code, tit. 16, art. 16.110, § 16.110.N1103.3.3
Corpus is an independent public-information project, not the official City of Overland Park website. Stable reference: corpuslaw.us/code/79caf280-58d3-472d-9819-127421d4dd33
16.110.N1103.3.3
Section N1103.3.3 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows: N1103.3.3 (R403.3.3) Duct testing (Mandatory). Where required by the Code Official, ducts shall be pressure tested to determine air leakage by one of the following methods: (1) 1. Rough-in-test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer’s air handler enclosure if installed at the time of the test. Registers shall be taped or otherwise sealed during the test. (2) 2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer’s air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: (1) 1. A duct air-leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. (2) 2. A duct air-leakage test shall not be required for ducts serving heat or energy recovery ventilators that are not integrated with ducts serving heating or cooling systems. A written report of the results of the test shall be signed by the party conducting the test and provided to the building official. (History: Ord. BC-3286 §73, 2020) Effective on: 1/1/1901
Ask a question about Overland Park law
Corpus searches the Overland Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.