§ 16.110.E3902.5

Code of the City of Overland Park, Kansas · Overland Park Municipal Code, tit. 16, art. 16.110, § 16.110.E3902.5

Corpus is an independent public-information project, not the official City of Overland Park website. Stable reference: corpuslaw.us/code/77d9d10f-8289-48da-8fa6-7163a47d567e

16.110.E3902.5

Section E3902.5 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows: E3902.5 Unfinished Basement Receptacles. 125-volt, single-phase, 15- and 20-ampere receptacles installed in unfinished basements shall have ground-fault circuit-interrupter protection for personnel. For purposes of this Section, unfinished basements are defined as portions or areas of the basement not intended as habitable rooms. [210.8(A)(5)]. Exception: 1. A dedicated receptacle supplying a garage door opener, fire alarm, security system, sump pump, refrigerator, freezer or electric vehicle charger. (History: Ord. BC-3286 §85, 2020; Ord. BC-2936 §58, 2012) Effective on: 1/1/1901