For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.110.M1502.4.2

Code of the City of Overland Park, Kansas · Overland Park Municipal Code, tit. 16, art. 16.110, § 16.110.M1502.4.2

Corpus is an independent public-information project, not the official City of Overland Park website. Stable reference: corpuslaw.us/code/39bbde20-2bca-420f-9eae-09e25b59ddc9

16.110.M1502.4.2

Section M1502.4.2 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows: M1502.4.2 Duct installation. Exhaust ducts shall be supported at intervals not to exceed 12 feet and shall be secured in place. The insert end of the duct shall extend into the adjoining duct or fitting in the direction of airflow. Exhaust duct joints shall be sealed in accordance with Section M1601.4.1 and shall be mechanically fastened. Ducts shall not be joined with screws or similar fasteners that protrude more than ⅛ inch into the inside of the duct. (History: Ord. BC-3286 §81, 2020) Effective on: 1/1/1901

Ask a question about Overland Park law

Corpus searches the Overland Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.