Sec. 8-1-1-1015.7. - Amendment to Section 1015.7 of the IBC.
Section 1015.7 of the IBC is amended to read as follows: Sec. 1015.7 Roof access. Guards shall be provided where the roof hatch opening is located within 10 feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches (762 mm) above the floor, roof or grade below. The guard shall be constructed so as to prevent the passage of a 21-inch-diameter (533 mm) sphere. Guards located within 3 feet of a roof edge shall have toe boards installed to help prevent objects from falling off the roof during maintenance operations. Exception: Guards are not required where personal fall arrest anchorage connector devices that comply with ANSI/ASSE Z 359.1 are installed.
(Ord. No. 25-11264, § 1, 12-8-25)