§ 8-1-1-1704.1 — Amendment to Section 1704.1 of the IBC

Salina Code, City of Salina, Kansas (Codified through Ordinance No. 26-11299 adopted August 24, 2026. (Supp. No. 19)) · Salina Municipal Code § 8-1-1-1704.1

Corpus is an independent public-information project, not the official City of Salina website. Stable reference: corpuslaw.us/code/ec0c11f6-4876-454d-8483-55a5f955b8fc

Sec. 8-1-1-1704.1. - Amendment to Section 1704.1 of the IBC.

Section 1704.1 of the IBC is amended to read as follows: Sec. 1704.1 General. Where application is made for construction as described in this section, the owner, the registered design professional in responsible charge acting as the owner's agent, or the contractor with the approval of the registered design professional in responsible charge shall employ one or more approved agencies and special inspectors to provide inspections during construction on the types of work listed under Section 1705. The special inspector shall be a qualified person who shall demonstrate competence, to the satisfaction of the registered design professional in responsible charge and the building official, for inspection of the particular type of construction or operation requiring special inspection. These inspections are in addition to the inspections specified in Section 110. Exceptions: 1. Special inspections and tests are not required for work of a minor nature or as warranted by conditions in the jurisdiction as approved by the registered design professional in responsible charge and the building official. 2. Unless otherwise required by the registered design professional in responsible charge and the building official, special inspections and tests are not required for occupancies in Group R-3 as applicable in Section 101.2 and occupancies in Group U that are accessory to a residential occupancy including, but not limited to, those listed in Section 312.1. 3. Special inspections and tests are not required for portions of structures designed and constructed in accordance with the cold-formed steel light-frame construction provisions of Section 2308. 4. Special inspections and tests are not required when determined not to be warranted in accordance with Section 1704.1.1. 1704.1.1 Building permit requirement. The permit applicant shall submit a statement of special inspections prepared, signed, and sealed by the registered design professional in responsible charge in accordance with Sections 1704.3.1; 1704.2.3 and 106.1 as a condition for permit issuance. The statement of special inspection may be included in the submitted plans and shall identify the following: 1. The materials, systems, components and work required to have special inspection or testing by the building official or by the registered design professional responsible for each portion of the work. A complete list of materials and work requiring special inspections by this section; 2. The type and extent of each special inspection. For each type of special inspection, identification as to whether it will be continuous or periodic in accordance with the applicable Tables 1705.2.2; 1705.3; 1705.6; 1705.7 and 1705.8; 3. The type and extent of each test and a list of the individuals, approved agencies or firms intended to be retained for conducting such inspections and tests; 4. Additional requirements for special inspection or testing for seismic or wind resistance as specified in Sections 1705.10, 1705.11 and 1705.12. If applicable, a statement by the registered design professional in responsible charge by which the design professional in responsible charge identifies as required (affirmative statement), based on the requirements of the IBC, Chapter 17; 5. The building official shall review the statement of special inspections. Should he identify required special inspections based on Chapter 17 that were not included in the statement, he can question those exclusions by communicating his concerns to the design professional through a plan review letter. The design professional must submit written justification for the omission of required special inspections, as identified by the building official. The building official reviews and responds to the design professional by either accepting his justification or invoking peer review. If peer review is invoked it is at the expense of the city and would include the hiring or contracting for services, by the city, of a person or persons licensed by the State of Kansas in the applicable technical profession for the purpose of determining whether the determination of the registered design professional in responsible charge should be followed or whether the special inspections in question shall instead be required, with or without modification. 1704.1.2 Report requirement. Special inspectors shall keep records of inspections. The special inspector shall furnish all inspection reports to the registered design professional in responsible charge and the building official. The reports may be submitted electronically. Reports shall indicate that work inspected was or was not completed and done in conformance to approved construction documents. Discrepancies shall be brought to the immediate attention of the contractor for correction. If the discrepancies are not corrected, the discrepancies shall be brought to the attention of the registered design professional in responsible charge and the building official prior to the completion of that phase of the work. A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted at a point in time agreed upon by the permit applicant and the building official and indicated on the statement of special inspections.

(Ord. No. 25-11264, § 1, 12-8-25)

Ask a question about Salina law

Corpus searches the Salina sections it holds and shows the ones that match, with their citations. Free, no sign-in.