Sec. 8-1-1-1809.5. - Amendment to Section 1809.5 of the IBC.
Section 1809.5 of the IBC is amended to read as follows: Sec. 1809.5 Frost protection. Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected by one or more of the following methods: 1. Extending below the frost line of the locality (36 inches); 2. Constructing in accordance with ASCE 32; or 3. Erecting on solid rock. Exception: Free-standing buildings meeting all of the following conditions shall not be required to be protected: 1. Classified in Occupancy Category I, in accordance with Section 1604.5; 2. Area of 400 square feet (56 m2) or less; and 3. Eave height of 10 feet (3048 mm) or less. Footings shall not bear on frozen soil unless such frozen condition is of a permanent character.
(Ord. No. 25-11264, § 1, 12-8-25)