For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-1-1-1704.2.5.1 — Amendment to Section 1704.2.5.1 of the IBC

Salina Code, City of Salina, Kansas (Codified through Ordinance No. 26-11299 adopted August 24, 2026. (Supp. No. 19)) · Salina Municipal Code § 8-1-1-1704.2.5.1

Corpus is an independent public-information project, not the official City of Salina website. Stable reference: corpuslaw.us/code/0d2b48e3-1ff7-46d2-b88e-1512d6b2f989

Sec. 8-1-1-1704.2.5.1. - Amendment to Section 1704.2.5.1 of the IBC.

Section 1704.2.5.1 of the IBC is amended to read as follows: Sec. 1704.2.5.1 Fabricator approval. Special inspections required by Section 1705 are not required where the work is done on a premises of a fabricator approved to perform such work without special inspection. Approval shall be based upon review of the fabricator's written procedural and quality control manuals and periodic auditing of fabrication practices by an approved special inspection agency. At completion of fabrication, the approved fabricator shall submit a certificate of compliance to the registered design professional in responsible charge and the building official stating that the work was performed in accordance with the approved construction documents.

(Ord. No. 25-11264, § 1, 12-8-25)

Ask a question about Salina law

Corpus searches the Salina sections it holds and shows the ones that match, with their citations. Free, no sign-in.