Sec. 13-148. - Same - Fuel.

(a) All incinerators creating a nuisance under the provisions of this article shall be equipped with gas washing devices, settling chambers or other approved devices for the elimination of the nuisance, if the superintendent determines that such devices will correct the existing nuisance. (b) All incinerators which shall be built, altered or remodeled, or those existing, shall use one of the following classifications of fuels for purposes of construction design only. (1) Fuel analysis, type 1 fuel. Rubbish, consisting of 75 percent dry combustible waste and moisture not to exceed 25 percent by weight. The term "rubbish" means fuel made up of combustible waste such as paper, rags, scrap wood, cartons, floor sweepings and by-products of industrial waste from manufacturing operations. In commercial operations it consists of all wrapping waste and offal from such operations. The 25 percent moisture represents normal moisture content in dry waste materials. Type 1 fuel is based on not more than 8,000 Btu per pound, having ten percent ash and 65 percent fuel. Secondary auxiliary fuel may be required in this type. (2) Type 2 fuel. Garbage, consisting of 65 percent wet materials and 35 percent dry materials. The term "garbage" means fuel made up of food wastes and spoilage from hotels, restaurants, hospitals, markets and like installations. Seventy-five percent of the wet materials is moisture, and 35 percent of the total load is rubbish, containing up to 25 percent moisture, ash and noncombustible eight percent, as charged. This type of fuel has 5,000 Btu per pound, as fired. Auxiliary fuel must be provided with Type 2 fuel, both primary and secondary. (3) Type 3 fuel. Refuse consisting of an even mixture of rubbish and garbage. This type of waste is common to industrial, commercial and institutional installations combining accumulation of combustible waste and garbage from cafeteria and food preparation work. Auxiliary fuel must be provided for Type 3 fuel. (4) Type 4 fuel. Human and animal remains and pathological waste which require primary and secondary auxiliary fuel, as dictated by individual job analysis. (5) Type 5 fuel. Byproduct waste, gaseous, liquid or semi-liquid, noxious or contaminated, of density and viscosity that will be burned through air or pressure atomizing burner equipment. Btu values must be set on individual materials to be destroyed. (6) Type 6 fuel. Byproduct waste, semi and solid, toxic or otherwise, to be direct charged on hearth, or refractory crucible. (Ord. No. 81-73, § 3.2-B, 11-4-81)

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.