Sec. 13-150. - Flue fed incinerators.

(a) All apartment and multiple dwellings shall be equipped with an approved incinerator of a Class II type. Flue fed equipment requires a separate flue for incinerator use only. Basement installations may be brick set or steel casing type. All brick set units shall use a minimum 4½ inches of refractory lining (33 to 34 P.C.E.) for grate burning areas up to nine square feet. Grate burning areas exceeding nine square feet using a brick setting shall use 4½ inches refractory lining of a 33 to 34 P.C.E. and an eight-inch common brick exterior wall. Ash pit and secondary combustion areas shall be lined with a minimum of two inches of approved insulating material where same is constructed on concrete slab. (b) Minimum flue requirements for new construction shall be 12 inches × 12 inches. Each flue lining shall be built of an approved refractory 4½ inches thick, 30 feet above the breeching line of incinerator, balance of same to be teracotta or approved equal. Self-closing hopper doors at each floor shall be used with daylight opening not to exceed 1/3 of the cross sectional area of the flue. Any incinerator using Type 3 fuel will be required to furnish secondary fuel. (c) Evidence of positive draft control must also be furnished. Approved fly ash collection equipment must also be furnished. The following details must also be included in the design: (1) Mean design temperature 1,500 degrees Fahrenheit; (2) The volume of the primary combustion chamber shall have a designated heat release of eight Btu per cubic foot per second; (3) Second combustion chamber to have an area normal to gas path such that maximum furnace heat release will not exceed 850,000 Btu per square foot of area, 25 feet per second; (4) Settling chamber to have an area normal to gas path such that minimum furnace heat release will not exceed 370,000 Btu per square foot of area, 11 feet per second; (5) Flue cross section area not less than one square foot for each 850,000 Btu's released in the furnace, 25 feet per second; (6) Chimney cross section area not less than one square foot per 780,000 Btu's of heat released in the furnace based on an assumed 50- to 60-foot stack. The equivalent velocity is about 23 feet per second; (7) Maximum burning capacity of the grates shall be 40 pounds per square feet per hour; (8) Calculation for combustion air shall be based on figuring zero excess air: Btu × 7.6 10,000 (9) Calculations to include provision for 50 percent excess air; (10) Total weight of products of combustion to equal total combustion air plus 90 percent of dry fuel; (11) Design of incinerator and its equipment for the disposition of moisture in the fuel shall also include the computation of the volumes for the control of velocities including the volume of the super-heated steam at the design unit temperature, plus the volume of the products of combustion. (Ord. No. 81-73, § 3.2-D, 11-4-81)

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.