Sec. 5-1266. - Amendments to electrical code.

The following sections of the National Electrical Code, 1990 Edition are hereby revised as follows: (a) Section 230. (1) Service equipment for residential occupancies of four units or less. Single phase 100 amp service panel boards rated 125 ampere providing space for 20 full size overcurrent devices with 100 amp main. Service cable shall be armored type assembly enclosed by concentric neutral. (2) Service equipment for multiple dwellings of over four occupancies. One main service and disconnect means for necessary connected load. Unless all current is through a bank of metering devices grouped in such a manner that there will be a maximum of six disconnects, all such multiple dwellings must have individual service disconnects. Where six or more two-wire branch circuits are installed, 100 ampere service is necessary. All others the service disconnecting means shall have a rating of not less than 60 amperes. (3) In computing the maximum number of 15 or 20 ampere breakers per bus-bar pole is based on ten amperes for each over current device (U. L. CTL concept). Difficulties with subpanels and so-called half-size and duplex-type circuit breakers replacing full size circuit breakers, on the basis of two poles for one, leads to doubling the number of branch circuit over-current devices, and resulting in overcrowding with wiring and overheated panel boards. Where no physical means for installation of all overcurrent devices necessary exists, anticipated seizure rating has to be increased. (4) Service panel. a. Panel not intended to be used as a junction box or for mounting devices, bell transformers, handy boxes for receptacles. b. Install service entrance cable perpendicularly (avoid unnecessary outside horizontal run) directly from meter can to service panel. c. Distribute conductors entering top of service panel (use knock-outs provided) dissipation of heat and withdrawal of conductors without damage to their insulation is not possible. d. Mount service panel in vertical position. e. Conductors other than service entrance cable shall not occupy same entrance knockout in service panel. f. A No. 6 service grounding electrode copper conductor shall be bonded effectively to a cold water galvanized or copper pipe no smaller than three-fourths inch trade size. Bond water meter. g. Not more than one conductor shall be connected to the neutral and grounding bar by a single (screw) pressure connector. h. Two conductors on one circuit breaker or fuse device is prohibited. i. Provide grounding bar for grounding conductors. (5) Existing main panels, sub-panels, fuse blocks, knob-tube platforms, and associated hardware located in basement, garage or apartment hallways or closets shall be removed. Enclosure in plastered wall can be used as a junction box after removing devices or apparatus connected within. (b) Article 220-32. Minimum size of conductors. (1) Residential occupancies, four dwelling units or less, each service entrance conductor shall be minimum three-wire, copper, No. 2 A.W.G. (2) In all other occupancies over four dwelling units demand factors shall be permitted National Electrical Code article 220-32. (Ord. No. 91-511, §§ 6.1, 6.2, 2-13-91)

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.