Sec. 5-1281. - Minimum requirements for dwellings.

The following minimum requirements must be observed in the constructing, installing, altering, or repairing of single and multiple dwellings: (1) No branch circuit shall be connected to serve more than one apartment. (2) Distribution panels shall be located in the apartment which they serve or in a public space, and shall not be located in bathrooms. (3) Stairways shall be provided with lighting outlet or outlets that will adequately light each stair section. (4) Unless served from a separate house meter, stairway outlets shall be controlled from the circuit or apartment using same. (5) Three-point switches shall be installed on all stairway lighting outlets. (6) Separate bell transformers shall be installed for each apartment, unless a common transformer is connected to the house meter bell, chime or enunciating system and contact switch required at residential entrances. (7) Halls, corridors and passageways in all multiple dwellings and motels shall have at least one light outlet every 20 feet or major fraction thereof. (8) Basements shall have one light outlet minimum for each 200 square feet. Furnace, laundry and enclosed or partitioned area must be provided with a light outlet. (9) Clothes closets and storage spaces shall have at least one light outlet installed therein. A wall switch control shall be provided at the entrance to each clothes closet. Clearance between the fixture and a storage area where combustible material may be stored is not less than 18 inches, (fluorescent fixture six inches clearance). Recessed fixture shall have thermal protection. Attics with scuttle holes must have a light near the opening and a light required back of all knee-walls. (10) Laundry washing machine receptacle outlet shall be a separate circuit of 20 ampere capacity and shall be at height of the laundry trays and within six feet of intended location of the equipment. The circuit must terminate in an outlet box on the wall. Mechanical protection (E.M.T.) for circuit below ceiling level must be provided. This receptacle shall be rated 20 ampere, grounding type 125 volts. (11) A lighting outlet shall be placed over each set of laundry trays, and may be connected to same circuit as that serving the laundry equipment. (12) Bathrooms and washrooms shall have switches controlling all lights therein. Mechanical fans shall be installed in all bathrooms and toilet rooms. See sections 5-1270 and 5-1271. (13) Wall switches shall be required for every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power, and outdoor entrances or exits. (14) An approved grounding type receptacle within sight of equipment and readily accessible at rear wall with a disconnecting means heavy duty 3-wire No. 16 service cord shall be provided for residential food waste grinders. A control switch above the counter mounted adjacent to the sink. Recess outlets into walls. Separate 15 amp circuit shall be provided. (15) A convenience outlet ground-fault circuit interrupter shall be installed on front and one on rear of each dwelling. These must be on a separate circuit, and each outlet must be separately switched. Switches must be separated from each other. (16) A spotlight shall be installed on the rear of each residence at a height sufficient to provide lighting for rear yard; must be switched at or near side door if one is provided. Fixture must be directional so light can be adjusted not to trespass property boundaries. (17) Multiple dwellings and motels which do not have a central air-conditioning system must provide at least one 220-volt convenience outlet in close proximity to an outside window in each dwelling unit. (18) Halls, corridors, and passageways in multiple dwelling and motels shall have at least one convenience outlet installed, spaced so no electrical cord will require to reach over 30 feet. (19) A 20 ampere 120 volt No. 12 A.W.G. conductor shall be largest size branch circuit permitted in attached and detached residential garages. All overcurrent devices must be located at service panel; when more than one circuit is provided, a potential of 120 volts must be maintained. All circuits are to originate from same bus at service panel board. Garage branch circuits shall serve garage only. (20) Every newly constructed single or multiple dwelling unit shall be provided with smoke detectors. The detectors shall be approved or listed by a recognized independent testing laboratory and, when actuated, shall provide an alarm suitable to warn the occupants within the individual dwelling unit. A minimum of one smoke detector shall be located in each of the following areas: a. In each apartment, suite or sleeping area. b. In the basement at the head of the landing leading to the ground level floor. c. Any other areas of the dwelling which, by reason of the dwelling layout, would not be protected by detectors located in subsection a. or b. above. Each detector shall be interlocked and electrically wired and connected to any lighting circuit. (Ord. No. 91-511, § 6.17, 2-13-91)

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.