§ 38.600.270 — Development requirements for uses, activities and artificial obstructions permitted in the flood fringe subject to issuance of a floodplain permit
Bozeman Municipal Code, City of Bozeman, Montana (Codified through Order No. 2026-11, adopted September 15, 2026. (Supp. No. 16, Update 1)) · Bozeman Municipal Code § 38.600.270
Corpus is an independent public-information project, not the official City of Bozeman website. Stable reference: corpuslaw.us/code/0593dc62-8c3a-4a81-857c-3301ff81de0c
Sec. 38.600.270. - Development requirements for uses, activities and artificial obstructions permitted in the flood fringe subject to issuance of a floodplain permit.
A. When a site specific exemption or relaxation of the standards of 38.620 allow utilization of a portion of the regulated flood hazard area, the uses, activities and artificial obstructions contained in this section, including alterations and substantial improvements to artificial obstructions, may be permitted in the flood fringe subject to issuance of floodplain permit. B. All uses, activities, and artificial obstructions permitted in the regulatory floodway pursuant to 38.600.260 may also be permitted in the flood fringe subject to issuance of a floodplain permit by the floodplain administrator. C. The requirements of this section shall also apply to uses, activities and artificial obstructions located in a regulated flood hazard area without a regulatory floodway and flood fringe, subject to: 1. An encroachment analysis shall be prepared and certified by a professional engineer demonstrating that the use, activity, or artificial obstruction in the regulated flood hazard area does not increase the identified base flood elevation more than 0.5 feet and does not significantly increase flood velocities or alter flood hazards to the detriment of upstream, downstream, or adjacent properties. D. The new construction, alteration, and substantial improvement of residential and non-residential buildings and structures may be permitted, provided that: 1. Such buildings and structures shall conform to the requirements of this chapter and chapter 10 and are not prohibited by any other statute, regulation, ordinance or resolution; 2. Such buildings and structures are compatible with local growth policies; 3. Such buildings and structures are constructed by methods and practices that minimize flood damage, and are reasonably safe from flooding and anchored to resist flotation, collapse and lateral movement; 4. Grading around such buildings and structures is provided with adequate surface drainage; 5. All materials used for construction are resistant to flooding to an elevation at least two feet above the base flood elevation; 6. New construction, alteration, and substantial improvement of residential buildings and structures, including manufactured homes, shall be elevated so that the lowest floor is at least two feet above the base flood elevation by any of the following means: a. On suitable structural fill, foundation wall enclosure, stem walls, pilings, posts, piers, columns or other acceptable means. b. If elevated on suitable structural fill, the fill must be extended at an elevation no lower than the base flood elevation for a minimum distance of 15 feet in all directions beyond the foundation walls, unless physical constraints exist that make strict compliance impracticable and the floodplain administrator approves a lesser distance, and be certified by a professional engineer to meet the following: (1) Fill material must be suitable for its intended purpose and be clean, well graded, pervious, not adversely affected by water and frost, devoid of trash or similar foreign matter, and free of tree stumps or other organic material; (2) Fill material must be compacted to 95 percent of its maximum density as determined by standard proctor testing in accordance with ASTM D698 standards; (3) Fill must not be placed within the regulatory floodway; and (4) Fill slope must be less than 1.5:1 unless physical constraints exist, in which case a retaining wall is allowed if the wall is adequately protected from erosion; 7. For new placement, substantial improvement, or replacement of manufactured homes, including those used for non-residential purposes, the building chassis shall be secure and resist flotation, collapse and lateral movement by anchoring with components capable of carrying a force of 4,800 pounds in addition to the following: a. For manufactured homes less than 50 feet long, over-the-top ties to ground anchors shall be provided at each of the four corners of the building, with two additional ties provided per side at intermediate locations; or b. For manufactured homes more than 50 feet long, frame ties to ground anchors shall be provided at each corner of the building, with five additional ties per side provided at intermediate points; 8. Non-residential buildings and structures shall be elevated so that the lowest floor is at least two feet above the base flood elevation in accordance with requirements of subsection D.6 of this section or shall be certified by a professional engineer or registered architect to be adequately floodproofed in accordance with the following: a. The lowest floor of the building or structure must be adequately wet or dry floodproofed to an elevation at least two feet above the base flood elevation; b. The building or structure shall be designed to withstand hydrostatic, hydrodynamic, and buoyancy forces of the base flood; c. Wet floodproofing is only permitted when the lowest floor of a building or structure is used for parking, loading, or storage of equipment or materials not appreciably affected by floodwater; d. Wet floodproofing must provide adequate openings to equalize hydrostatic forces; and e. Dry floodproofing must not allow floodwaters to cause internal flooding of the building or structure by using impermeable membranes and materials for construction of floors and walls, and must ensure that all windows, doors and other openings are watertight and do not allow the passage of floodwaters; 9. Except as provided in subsection 9.a. below, appurtenant or accessory buildings and structures for residential, non-residential, and agricultural purposes shall be elevated or floodproofed to an elevation at or above the base flood elevation and be adequately anchored to resist flotation, collapse and lateral movement. Means of elevating or floodproofing shall be in accordance with D.6 and D.8 above; a. Attached and detached garage structures used exclusively for parking or storage of equipment and materials not appreciably affected by floodwater shall be elevated in accordance with D.6; 10. The floor elevation of any crawlspace foundation enclosures, including subgrade crawlspaces with a floor elevation no more than two feet below the lowest adjacent grade of the building on all sides, shall be at or above the base flood elevation and contain flood openings designed and certified by a professional engineer to meet or exceed the following: a. Equalize hydrostatic forces on foundation walls by allowing the automatic entry and exit of floodwaters through screens, louvers, valves, or other covers or devices; b. Have two or more openings with a total net area of not less than one square inch for every one square foot of enclosed area below the lowest floor; c. Openings shall be located on a minimum of two walls, except for subgrade crawlspace enclosures where a minimum of two openings may be provided on a single wall; and d. The bottom of all openings shall be no higher than one foot above the higher of the exterior adjacent grade elevation or the crawlspace floor elevation; 11. Basements are considered the lowest floor of a building and shall be elevated two feet or more above the base flood elevation. A basement includes any floor that is more than two feet below the lowest adjacent grade of the building on all sides; 12. All electrical systems shall be certified by a professional engineer to satisfy all applicable flood hazard area provisions of the current adopted building codes set forth in chapter 10 along with the following requirements. If conflicts exist between this division and chapter 10, then chapter 10 requirements shall govern; a. All incoming power service equipment including all metering equipment, control centers, transformers, distribution and lighting panels, and all other stationary equipment shall be located at least two feet above the base flood elevation; b. Portable and movable electrical equipment may be placed below the base flood elevation, provided that the equipment can be disconnected by a single plug and socket assembly of the submersible type; c. The main power service lines must have automatically operated electrical disconnect equipment or manually operated electrical disconnect equipment located at an accessible remote location outside the regulated flood hazard area or shall be two feet above the base flood elevation; and d. All electrical wiring systems installed below the base flood elevation shall be suitable for continuous submergence and may not contain fibrous components; 13. All mechanical systems shall be certified by a professional engineer to satisfy all applicable flood hazard area provisions of the current adopted building codes set forth in chapter 10 along with the following requirements. If conflicts exist between this division and chapter 10, then chapter 10 requirements shall govern; a. Float operated automatic control valves shall be installed so that fuel supply is automatically shut off when flood waters reach the floor level where mechanical systems are located; b. Manually operated gate valves shall be installed on gas supply lines. The gate valves shall be operable from a location above the base flood elevation; c. Electrical components of the HVAC systems shall meet the requirements of D.12 above; and d. Furnaces, cooling units, and all associated ductwork shall be installed at least two feet above the base flood elevation; 14. All plumbing systems shall be certified by a professional engineer to satisfy all applicable flood hazard area provisions of the current building codes set forth in chapter 10 along with the following requirements. If conflicts exist between this division and chapter 10, then chapter 10 requirements shall govern: a. The building sewer line shall have a backwater valve installed to prevent sewage backup into the building; and b. All toilets, stools, sinks, urinals, vaults, and drains shall be located so the lowest point of possible flood water entry is at least two feet above the base flood elevation. E. Recreational vehicles may be permitted, provided that: 1. Recreational vehicles that are on site for more than 180 days out of the year, or are not ready for highway use, shall meet the manufactured home requirements in subsection D.6 and subsection D.7. F. Mining or excavation of material from pits or pools provided that: 1. A buffer strip of undisturbed land of sufficient width to prevent the base flood from channeling into the mine or excavation is left between the edge of the channel and the edge of the mine or excavation; 2. The mine or excavation meets all applicable laws and regulation of other local and state agencies; and 3. Mined or excavated material is stockpiled outside of the regulatory floodway. G. All other uses, activities and artificial obstructions not otherwise prohibited by 38.600.250.B or any other provision of this chapter may be permitted in the flood fringe subject to issuance of a floodplain permit.
(Ord. No. 2025-12, § 4(Exh. A), 12-16-2025)