For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18-763 — Development standards near class SA waters

Code of Ordinances of the City of Wilmington, North Carolina (Supp. No. 43, Update 1: codified through Ordinance No. O-2026-51, enacted October 20, 2026) · Wilmington Code of Ordinances § 18-763

Corpus is an independent public-information project, not the official City of Wilmington website. Stable reference: corpuslaw.us/code/bc544c83-3f71-4782-9ab0-c679bdf7fcdd

Sec. 18-763. - Development standards near class SA waters.

Development within one-half (½) mile of waters classified by the commission as class SA waters and draining to unnamed freshwater tributaries to class SA waters shall be permitted as follows: (a) Low-density projects. Development shall comply with all of the following standards in addition to the general standards in section 18-760 in order to be considered low-density: (1) The development has an impervious surface area of twelve (12) percent or less. A development project with an overall density at or below the low-density threshold, but containing areas with a density greater than the overall project density, shall be considered low-density as long as the project meets or exceeds the requirements for low-density development and locates the higher density development in upland areas and away from surface waters and drainage ways to the maximum extent practicable taking existing site constraints into consideration. (2) Stormwater runoff from the development is transported primarily by a vegetated conveyance system. As used in this section, "conveyance system" shall not include a stormwater collection system. Stormwater runoff from impervious surface areas that is directed to flow through any wetlands shall flow into and through these wetlands at a nonerosive velocity. (b) High-density projects. Development shall comply with all of the following standards in addition to the general standards in section 18-760 in order to be considered high-density: (1) The development has an impervious surface area of greater than twelve (12) percent. (2) The development has no direct outlet channels or pipes to class SA waters unless permitted in accordance with the design manual. Stormwater runoff from impervious surface areas that is directed to flow through any wetlands shall flow into and through these wetlands at a nonerosive velocity. (3) The water quality volume for design of the stormwater system is the stormwater runoff from all surfaces generated by one and one-half (1½) inches of rainfall or the difference in the stormwater runoff from all surfaces from the predevelopment and post development conditions for a one-year, 24-hour storm, whichever is greater. Runoff volume drawdown time shall be a minimum of forty eight (48) hours, but not more than one hundred twenty (120) hours. (4) The development utilizes control systems that are any combination of infiltration systems, bioretention systems, constructed stormwater wetlands, sand filters, rain barrels, cisterns, rain gardens or alternative low impact development stormwater management systems designed in accordance with the design manual to treat the runoff from all surfaces generated by one and one-half (1½) inches of rainfall. Wet detention ponds may be used as a stormwater control system to meet the requirements of this section, provided that the stormwater control system fully complies with the requirements of this section. If a wet detention pond is used within one-half (½) mile of class SA waters, installation of a stormwater best management practice in series with the wet detention pond shall be required to treat the discharge from the wet detention pond. Secondary stormwater best management practices that are used in series with another stormwater best management practice do not require any minimum separation from the seasonal high water table. (5) Stormwater runoff from the development that is in excess of the design volume must flow overland through a vegetative filter designed in accordance with design manual with a minimum length of fifty (50) feet measured from mean high water of class SA waters. (6) All structural stormwater treatment systems used to meet these requirements shall be designed to have a minimum of eighty-five (85) percent average annual removal for total suspended solids (TSS). (7) General engineering design criteria for all projects shall be in accordance with 15A NCAC 2H .1008(c), as explained in the design manual. (c) Stormwater discharges prohibited. All development activities, including both low-density and high-density projects, shall prohibit new points of stormwater discharge to class SA waters or an increase in the volume of stormwater flow through conveyances or increase in capacity of conveyances of existing stormwater conveyance systems that drain to class SA waters. Any modification or redesign of a stormwater conveyance system within the contributing drainage basin must not increase the net amount or rate of stormwater discharge through existing outfalls to class SA waters. The following shall not be considered a direct point of stormwater discharge: (1) Infiltration of the stormwater runoff from the water quality volume as described in this section. (2) Diffuse flow of stormwater at a nonerosive velocity to a vegetated buffer or other natural area, that is capable of providing effective infiltration of the runoff from the water quality volume as described in this section. The infiltration mandated in this section does not require a minimum separation from the seasonal high water table, however all other requirements of this division must be met. (3) The discharge from a wet detention pond that is treated by a secondary stormwater best management practice, provided that both the wet detention pond and the secondary stormwater best management practice meet the requirements of this section. (d) BMPs for use in SA watersheds. BMPs that result in the highest degree of fecal coliform die-off and that meet the requirements for the density of the project shall be used. Structural and nonstructural BMPs shall control sources of fecal coliform to the maximum extent practicable. The city engineer shall maintain and annually update technical standards for BMPs that are determined as effective for removing fecal coliform.

(Ord. No. O-2009-92, § 2, 9-15-09)

Ask a question about Wilmington law

Corpus searches the Wilmington sections it holds and shows the ones that match, with their citations. Free, no sign-in.