Sec. 18-764. - Development standards for all other areas.

Development activities within the city except those areas near ORW and SA waters as described in previous sections of this division shall meet the following requirements: (a) Low-density projects. Development shall comply with all of the following standards in addition to the general standards in section 18-760 in order to be considered low-density: (1) The development has an impervious surface area of twenty-four (24) percent or less. A development project with an overall density at or below the low-density threshold, but containing areas with a density greater than the overall project density, shall be considered low density as long as the project meets or exceeds the requirements for low-density development and locates the higher density in upland areas and away from surface waters and drainage ways to the maximum extent practicable taking existing site constraints into consideration. (2) Stormwater runoff from the development is transported primarily by vegetated conveyances systems. As used in this section, "conveyance system" shall not include a stormwater collection system. Stormwater runoff from impervious surface areas that is directed to flow through any wetlands shall flow into and through these wetlands at a nonerosive velocity. (b) High-density projects. Development shall comply with all of the following standards in addition to the general standards in section 18-760 in order to be considered high-density: (1) The development has an impervious surface area of greater than twenty-four (24) percent. (2) The development uses control systems that are any combination of infiltration systems, wet detention ponds, bioretention systems, constructed stormwater wetlands, sand filters, rain barrels, cisterns, or rain gardens. (3) The water quality volume for design of the stormwater system is the stormwater runoff from all surfaces generated by one and one-half (1½) inches of rainfall. Runoff volume drawdown time shall be a minimum of forty eight (48) hours, but not more than one hundred twenty (120) hours. (4) Control systems must be designed to treat the stormwater runoff from all surfaces generated by one and one-half (1½) inches of rainfall. (5) Stormwater runoff from impervious surface areas that is directed to flow through any wetlands shall flow into and through these wetlands at a nonerosive velocity. (6) All structural stormwater treatment systems used to meet these requirements shall be designed to have a minimum of eighty-five (85) percent average annual removal for total suspended solids (TSS). (7) General engineering design criteria for all projects shall be in accordance with 15A NCAC 2H .1008(c), as explained in the design manual.

(Ord. No. O-2009-92, § 2, 9-15-09)

Ask a question about Wilmington law

Corpus searches the Wilmington sections it holds and shows the ones that match, with their citations. Free, no sign-in.