§ 25.12.170 — Section 306.5 Amended; Equipment and Appliances on Roofs or Elevated Structures

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 25.12.170

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/c92177bf-1596-4fd1-baaf-cd0015730542

25.12.170 Section 306.5 Amended; Equipment and Appliances on Roofs or Elevated Structures.

Section 306.5 of the International Fuel Gas Code is amended to read as follows: 306.5 Equipment and appliances on roofs or elevated structures. Where equipment requiring access or appliances are located on an elevated structure or the roof of a building such that personnel will have to climb higher than 16 feet (4877 mm) above grade to access such equipment or appliances, an interior or exterior means of access shall be provided. Such access shall not require climbing over obstructions greater than 30 inches (762 mm) in height or walking on roofs having a slope greater than 4 units vertical in 12 units horizontal (33-percent slope). Such access shall not require the use of portable ladders. Where access involves climbing over parapet walls, the height shall be measured to the top of the parapet wall. Permanent ladders installed to provide the required access shall comply with the following minimum design criteria: (1) 1. The side railing shall extend above the parapet or roof edge not less than 30 inches (762 mm). (2) 2. Ladders shall have rung spacing not to exceed 14 inches (356 mm) on center. The uppermost rung shall be not greater than 24 inches (610 mm) below the upper edge of the roof hatch, roof or parapet, as applicable. (3) 3. Ladders shall have a toe spacing not less than 6 inches (152 mm) deep. (4) 4. There shall be not less than 18 inches (457 mm) between rails. (5) 5. Rungs shall have a diameter not less than 0.75-inch (19.1 mm) and be capable of withstanding a 300-pound (136 kg) load. (6) 6. Ladders over 30 feet (9144 mm) in height shall be provided with offset sections and landings capable of withstanding 100 pounds per square foot (488 kg/m2). Landing dimensions shall be not less than 18 inches (457 mm) and not less than the width of the ladder served. A guard rail shall be provided on all open sides of the landing. (7) 7. Climbing clearance. The distance from the centerline of the rungs to the nearest permanent object on the climbing side of the ladder shall be not less than 30 inches (762 mm) measured perpendicular to the rungs. This distance shall be maintained from the point of ladder access to the bottom of the roof hatch. A minimum clear width of 15 inches (381 mm) shall be provided on both sides of the ladder measured from the midpoint of and parallel with the rungs except where cages or wells are installed. (8) 8. Landing required. The ladder shall be provided with a clear and unobstructed bottom landing area having a minimum dimension of 30 inches (762 mm) by 30 inches (762 mm) centered in front of the ladder. (9) 9. Ladders shall be protected against corrosion by approved means. (10) 10. Access to ladders shall be provided at all times. Catwalks installed to provide the required access shall be not less than 24 inches (610 mm) wide and shall have railings as required for service platforms. (11) 11. All buildings requiring permanent ladder access shall have the bottom of ladders accessible at a height of ten feet or less from grade or floor level. On new construction, equipment shall only be accessed through the area that it serves. Equipment shall not be accessed through other parts of a building where there are separate ownership or tenants. Equipment shall be accessed directly from the area served, through a common area, or accessed on the outside of the building on new commercial construction. Where equipment and appliances requiring access are installed on roofs or elevated structures at a height exceeding 16 feet (4877 mm), such access shall be provided by a permanent approved means of access, the extent of which shall be from grade or floor level to the equipment and appliances’ level services space. Exception: Equipment on roofs of existing commercial and Group R-1 residential buildings less than 24 feet in height may be accessed by portable ladders. Permanent level platforms or staging areas such as roofs or balconies having a minimum dimension of 6 feet by 6 feet may be considered to reduce the 24-foot minimum height. (: Ord. 20528 §20, August 21, 2017).

(Ord. 21816 §15; December 15, 2025)