§ 25.12.232 — Section 614.9.2 Amended; Duct Installation
Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 25.12.232
Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/e7b6f969-f02e-4fc7-9948-e44f87cd14a2
25.12.232 Section 614.9.2 Amended; Duct Installation.
Section 614.9.2 of the International Fuel Gas Code is amended to read as follows: Exhaust ducts shall be supported at intervals not to exceed 10 feet and be secured in place. The insert end of the duct shall extend into the adjoining duct or fitting in the direction of airflow. Ducts shall not be joined with screws or similar fasteners that protrude into the inside of the duct. Where dryer exhaust ducts are enclosed in wall or ceiling cavities, such cavities shall allow the installation of the duct without deformation. ().
(Ord. 21816 §27; December 15, 2025; Ord. 21114 §18; August 23, 2021)