For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 403-10 — Disinfection

Code of the City of Clifton, New Jersey (Code 2026-10-20) · Clifton City Code § 403-10

Corpus is an independent public-information project, not the official City of Clifton website. Stable reference: corpuslaw.us/code/07837720-6120-4a35-9c2c-00fbd669ffed

§ 403-10: Disinfection.

A. Disinfecting agents. Means shall be provided for continuous and effective disinfection of swimming pool waters so as to result in compliance with the bacterial quality standards established in § 403-17E of this article. B. Gas chlorination. Gas-chlorinating devices shall be of the solution-feed type. The chlorinator and cylinders of chlorine shall be housed in a reasonably gastight corrosion-resistant and mechanically vented enclosure. When located below grade, airtight ducts from the bottom of the enclosure, provided with a motor-driven exhaust fan capable of producing at least one air change per minute to atmosphere, shall be provided. Automatic louvers of good design located near the top of the enclosure for admitting fresh air are required. Electrical switches for control of artificial lighting and ventilation shall be on the outside of the enclosure adjacent to the door. A gas mask, of the type approved by the United States Bureau of Mines, shall be provided and kept in an unlocked cabinet located outside the enclosure adjacent to the entrance door to the enclosure. The chlorinating unit shall be capable of supplying at least one pound of chlorine per eight hours for each 10,000 gallons of swimming pool capacity. Scales shall be provided for determining the loss of weight of chlorine gas. A valve stem wrench shall be maintained on the chlorine cylinder or cylinders in use so the supply can be shut off quickly in case of an emergency. Valve-protection hoods shall be kept in place except when the chlorine cylinders are in use. C. Hypofeeders. When a hypochlorite solution is to be fed through hypofeeding equipment, such equipment shall provide the following features: (1) Feed shall be positive under all conditions of pressure in the circulating system, without artificial constriction of the pump suction line, whether this line is under vacuum or pressure head. (2) Means for regulation shall be provided to ensure constant feed with varying supply or back pressure. (3) Positive features to prevent backflow from the recirculating system to the solution container and provision for reducing to a minimum the entry into the swimming pool of inert material released from calcium hypochlorite. (4) Provision to prevent siphoning of hypochlorite solution when the recirculation pump and hypochlorinator are both turned off (applicable to above-swimming-pool-level installation only). The addition of ammonia to chlorine solutions for the purpose of forming chloramines as the disinfecting agent shall not be allowed without special permission of the administrative authority or its authorized agent. D. Bromination. Brominators, when provided, shall have capacities of at least two pounds of bromine per day for each 10,000 gallons of pool volume. Brominator equipment rooms shall be constructed and ventilated as required in § 403-10B. E. Other disinfecting agents. The administrative authority may accept other disinfecting materials or methods when they have been adequately demonstrated to provide a satisfactory residual effect which is easily measured and equally as effective in conditions of use as the chlorine concentration specified herein and to not be dangerous to public health, create objectionable physiological effects or impart toxic properties to the water.

Ask a question about Clifton law

Corpus searches the Clifton sections it holds and shows the ones that match, with their citations. Free, no sign-in.