§ 403-8 — Recirculation system
Code of the City of Clifton, New Jersey (Code 2026-10-20) · Clifton City Code § 403-8
Corpus is an independent public-information project, not the official City of Clifton website. Stable reference: corpuslaw.us/code/bd4961ca-c61d-48f1-8412-337a3d97afe6
§ 403-8: Recirculation system.
A. Capacity. A recirculation system consisting of pumps, piping, filters, water conditioning and disinfecting equipment and other accessory equipment shall be provided, which will clarify and disinfect the swimming pool volume of water in eight hours or less, thus providing a turnover of at least three times in each twenty-four-hour period. When wading pools are incorporated in the same area, the recirculation system shall be modified to also meet the turnover requirements for wading pools. B. Pumps. Pumps shall have capacities as required in § 403-8A and also be capable of backwashing filters. Pumps located above pool level shall be of self-priming design. If filters are above the waterline of a pool, a check valve in the suction line is required. Recirculation pumps used in conjunction with suction cleaners shall be designed to operate against a total dynamic head of at least 50 feet at the rated capacity. C. Piping. (1) The piping system shall be designed to: (a) Fill the pool. (b) Circulate the pool water through the treatment equipment. (c) Wash each filter individually. (d) Filter to waste. (e) Operate suction cleaner if recirculation pumps are used. (f) Empty the pool. (g) Drain the entire system. (2) Flange joints or unions shall be inserted at intervals to permit any part of the system to be cleaned and repaired. (3) Sampling taps shall be placed conveniently for obtaining samples of the water entering and leaving the pool. These taps may be located in conjunction with influent and effluent pressure gauges. D. Piping systems shall be identified as required by the administrative authority. E. Protection of potable water supply. Physical connections between potable water systems and swimming pool circulation systems shall not be permitted. Potable water for makeup purposes shall be introduced either into a float-controlled surge tank having an air gap at least six inches above the overflow rim of the tank or directly into the pool by means of a discharge pipe located beneath a diving board and turned downward with an air gap at least six inches above the pool overflow level. Water injector equipment shall use water either from the surge tank or recirculating system. Where the recirculation pump is not adequate to operate such equipment, auxiliary pump(s) shall be provided. F. Hair and lint catcher. At least one catcher shall be installed with duplicate strainer baskets provided. The catcher shall be located on the suction side of all pumps. Catcher covers shall be held in place by suitable means for quick removal of the strainer for cleaning purposes. Valves shall be installed adjacent to the strainer in order that the flow may be shut off during cleaning or inspection. A gauge shall be provided to determine head losses in each catcher. Strainers shall be of noncorrosive material; circular openings, when provided, shall have diameters not exceeding 1/8 inch; square mesh openings shall not exceed 1/10 inch on each side. Slotted strainers shall not exceed 1/10 inch in width nor one inch in length. The total area of strainer openings shall be at least 10 times the cross-sectional area of the main circulatory line from the pool drain. G. Vacuum cleaners. Vacuum cleaners either of the portable type or as part of the permanent piping system are required. Integral connections, when provided, shall be in sufficient number and located in the sidewall of the pool at least six inches below the water level, or as adapted to surface skimmers. Pool connections shall not project beyond the sidewall. Fixed pipe connections shall be at least two inches in diameter and shall be connected to the pump suction through the hair and lint catcher. A means shall be provided to throttle flow from the pool outlets in order to permit maximum efficiency when a vacuum cleaner is to be operated by a recirculation pump. H. Inlets. Inlets for fresh and/or recirculated filtered water shall be located to produce a uniform circulation of water without the existence of dead spots to facilitate the maintenance of a uniform disinfectant residual throughout the entire swimming pool. Inlets shall not be closer than 12 inches from the overflow level, unless provided with a suitable device for eliminating surface turbulence. Inlet fittings shall be designed so as not to create a hazard to bathers. The flow of water through inlets shall be controlled either by means of valves or adjustable orifices. I. Outlets. Outlet openings shall have an area of at least four times the discharge pipe area. When outlets are installed in the pool floor near one end, the spacing shall not be greater than 20 feet on centers, and the outlets shall not be installed more than 15 feet from any sidewall. At least one outlet shall be provided at the lowest point of the floor to completely drain the entire floor area. The floor outlet shall not permit a flow of water greater than two feet per second through the grating, and the slotted openings in the grate shall not be over 1/2 inch wide. Where outlet fittings consist of parallel plates of an antivortex-type fitting where the water enters the fitting from the sides, entrance velocities may be increased to six feet per second.
Ask a question about Clifton law
Corpus searches the Clifton sections it holds and shows the ones that match, with their citations. Free, no sign-in.