§ 403-9: Filtration.

A. General. Suspended matter in pool water shall be removed by means of adequate filtration equipment designed and operated as provided herein. All filters shall be of corrosion-resistant material. Sufficient filtering area shall be provided to meet the design criteria specified in § 403-8A. B. Sand or anthracite filters. Where sand filters are proposed, at least two such filters connected in parallel shall be provided. Filter media shall consist of sand or anthracite, with filter gravel or quartz supporting the filter bed. The effective size of the filter media shall be 0.45 to 0.55 millimeter, with a uniformity coefficient not greater than 1.75, and free of clay, organic and soluble matter. The effective depth of the filter media shall not be less than 20 inches. The total depth of each filter bed shall be at least 36 inches. The rate of filtration shall not be greater than three gallons per minute per square foot of effective filter surface area. The minimum rate of backwash shall be 12 gallons per minute per square foot of filter area for sand; eight gallons per minute per square foot of filter area for anthracite. The amount of freeboard to overflow troughs or pipes shall be at least 1/2 the depth of filter sand. Underdrains shall be designed to obtain uniform flow when either washing or filtering. C. Pressure sand filters. The type and depth of filter media and the rate of filtration for pressure sand filters shall be the same as required for sand filters in § 403-9B. D. Chemical application. Devices with reasonably accurate dosage control features shall be provided for adding coagulants ahead of the filters. E. Diatomaceous earth filters. These filters may be either of the pressure- or vacuum-type. (1) Pressure. The design filter rate shall not exceed two gallons per minute per square foot of effective filter area. With slurry feed, the rate shall not exceed 2 1/2 gallons. (2) Vacuum. The same design criteria applicable to pressure equipment shall apply. F. Other filters. Other filters may be considered under the provisions of § 403-4D of this article. Higher rate filters may be accepted, provided that the units have the National Sanitation Foundation seal of approval. G. Gauges. Loss-of-head gauges shall be installed on all open sand filters. Pressure gauges shall be installed on the inlet and outlet pipe of pressure filters. Such gauges shall be at least six inches in diameter and readable to one-pound pressure. Gauges to be read in pairs shall be set at the same elevation. H. Flow meters. Rate-of-flow meters shall be installed and located so that both the rate of recirculation and backwashing will be registered in gallons per minute. Meters shall be installed on a straight length of pipe at a distance from any valve, elbow or other source of turbulence equal to at least six times the diameter of the pipe. This requirement may be waived for meters not affected by pipeline turbulence. I. Sight glasses. Pressure filters shall be provided with sight glasses installed on the waste discharge line in order that filter washing progress may be determined. Such sight glasses shall be readily removable for cleaning purposes. J. Air-relief valves. Each pressure filter shall be equipped with an air-relief valve at or near the high point and located as to be readily accessible. K. Headroom. Pressure filters shall be designed, located and constructed to permit removal of filter heads for inspection, replacement or repair of the filter elements or media. L. Sump. A sump shall be provided to receive filter backwash water. There shall be an air gap not less than six inches between the discharge pipe opening and the overflow level of the sump.

Ask a question about Clifton law

Corpus searches the Clifton sections it holds and shows the ones that match, with their citations. Free, no sign-in.