§ 403-5 — Design and construction
Code of the City of Clifton, New Jersey (Code 2026-10-20) · Clifton City Code § 403-5
Corpus is an independent public-information project, not the official City of Clifton website. Stable reference: corpuslaw.us/code/130797db-aecb-4177-be03-401b7fa1d45e
§ 403-5: Design and construction.
A. Location. The site of all proposed swimming pools shall be such that proper and adequate water supply and waste disposal facilities will be available. In the case of outdoor pools, topography, protection from prevailing winds, the absence of trees in the near vicinity, distance from dusty roads and smoke-producing industries shall be considered in determining the suitability of proposed sites. B. Layout. Pool layout shall be such that bathers leaving the dressing rooms will first have access to toilets and then shower facilities. Exits and entrances shall preferably be located at the shallow end of the pool. The requirement relating to dressing rooms, bathhouses and toilets and showers may be waived when such facilities are conveniently available to bathers. C. Materials of construction. All materials used shall be durable, waterproof and easily cleaned, as well as inert and nontoxic to man. The bottom and sides of pools shall be finished in white or light color and shall be free from cracks or open joints. Walkways around pools shall be light of color, easily cleaned and slip-proof. Sand or earth bottoms directly exposed to the pool water shall not be permitted. D. Size. The pool area shall be proportioned as follows: (1) Ten square feet shall be provided for each nonswimmer expected to be present at the time of maximum load. Nonswimming sections shall be less than five feet in depth. (2) Twenty-four square feet shall be provided for each swimmer expected to be present at the time of maximum load. Swimming sections shall be greater than five feet in depth. (3) Three hundred square feet shall be reserved around each diving board or platform provided for diving purposes and shall not be included in determining the area of the swimming section. E. Diving area design. The water depths and dimensions of swimming pool diving areas shall be in accordance with the Sketch No. 1.[1] F. Bottom slope. The slope of the bottom of a pool having a water depth of less than five feet shall not exceed 1:10, except in pools less than 1,200 square feet where a slope of 1:8 may be permitted, provided that a lifeline shall be installed at least two feet from the transition point toward the shallow end. (See Sketch No. 1.[2]) G. Walls. (1) Walls of a swimming pool shall be either vertical for water depths of at least six feet, or vertical for a distance of three feet below the water level, below which the wall may be curved to the bottom with a radius not greater than the difference between the depth at that point and three feet, provided that vertical is interpreted to permit slopes not greater than one foot horizontal for each five feet of depth of sidewall (11º from vertical). (2) Safety ledges when provided on vertical walls in the deep portion of the swimming pool shall not be over four inches wide, at least four feet below the water surface and shall slope 1/2 inch in four inches toward the pool. H. Marking. Critical depths of pools are those at both ends and also at change-of-slope locations of the pool. Such critical depths shall be conspicuously marked in a permanent manner on either or both the horizontal or vertical surfaces of the pool above the water level. Markings at one-foot depth intervals are considered desirable. I. Overflow collection system. An overflow gutter, automatic skimmer(s) or other satisfactory cleaning device shall be provided for all public swimming pools. J. Overflow gutters. On pools where overflow gutters are proposed, they shall extend completely around the swimming pool, except at steps. The overflow gutter shall also serve as a handhold. This gutter shall be capable of continuously removing 50% or more of the recirculated water and return it to the filter. The gutter, drains and return piping to the surge tank should be designed to rapidly remove overflow water caused by recirculation displacement, wave action or other causes produced from the maximum pool bathing load. The opening into the gutter beneath the coping shall be not less than four inches, and the interior of the gutter shall be not less than three inches wide with a depth of at least three inches. Where large gutters are used, they shall be designed to prevent entrance or entrapment of bathers' arms and legs. The overflow edge or lip shall be rounded and not thicker than 2 1/2 inches for the top two inches. The overflow outlets shall be provided with outlet pipes or other suitable conduits, which shall in any case be at least two inches in diameter. The outlet fittings shall have a clear opening in the grating at least equal to 1 1/2 times the cross-sectional area of the outlet pipe. Nothing in this subsection shall preclude the use of roll-out or deck-level-type swimming pools. Such designs shall conform to the general provisions relating to overflow rates. The design of the curb and handhold shall conform to accepted standards, and approval shall be based on detailed review of this feature of construction and evaluated in the light of proposed use of the pool. K. Skimmers. Skimmers are permitted on public swimming pools, provided that approved handholds are installed and sufficient motion to the pool water is induced by the pressure-return inlets. At least one skimming device shall be provided for each 600 square feet of water surface area or fraction thereof. Where two or more skimmers are required, they shall be so located as to minimize interference with each other and to ensure proper skimming of the entire pool surface. Skimming devices shall be built into the pool wall, shall develop sufficient velocity on the pool water surface to induce floating oils and wastes into the skimmer from the water surface of the entire pool area, and shall meet the following general specifications: (1) Handholds shall consist of bull-nozed coping not over 2 1/2 inches thick for the outer two inches or an equivalent approved handhold. The handholds must be no more than nine inches above the normal waterline. (2) The piping and other pertinent components of skimmers shall be designed for a total capacity of at least 80% of the required filter flow of the recirculation system, and no skimmer shall be designed for a flow-through rate of less than 30 gallons per minute or 3.75 gallons per minute per linear inch of weir. (3) The skimmer weir shall be automatically adjustable and shall operate freely with the continuous action to variations in water level over a range of at least four inches. The weir shall be of such buoyancy and design so as to develop an effective velocity. (4) An easily removable and cleanable basket or screen through which all overflow water must pass shall be provided to trap large solids. (5) The skimmer shall be provided with a device to prevent air lock in the suction line. If an equalizer pipe is used, it shall provide an adequate amount of water for pump suction should the water of the swimming pool drop below the weir level, provided that, if any other device, surge tank or arrangement is used, a sufficient amount of water for pump suction shall be assured. (6) Where the equalizer pipe is used, it shall be sized to meet the capacity requirements of the filter and pump and shall in no case be less than two inches in diameter. This pipe shall be located at least one foot below the lowest overflow level of the skimmer, it shall be provided with a valve or equivalent device that will remain tightly closed under normal operating conditions, but will automatically open when the water level drops as much as two inches below the lowest weir level. (7) The skimmer shall be of sturdy, corrosion-resistant materials. L. Decks and walkways. A continuous deck at least five feet [and preferably eight or more feet] wide shall extend completely around the swimming pool. The deck shall be sloped away from the pool to drain at a grade of 1/4 inch to 3/8 inch per linear foot and shall have a nonslip surface. Deck drains shall not be connected to the recirculation system or gutters, except as permitted in § 403-5J. M. Ladders and stairs. Ladders for entering and leaving a pool shall be constructed of nonslip tread and shall be located at both sides of the deep section. If the wall height at the shallow end of a pool is more than two feet, ladders or steps shall be provided. Where stairs are proposed, they shall be installed only at the shallow end of the pool. Stairs, ladders or steps shall have a handrail on either side, with the top leading out over the walkway. There shall be a clearance of not more than five inches nor less than three inches between any ladder and the pool wall. If steps are inserted in the walls or if step holes are provided, they shall be of such design that they may be cleaned readily and shall be arranged to drain into the pool to prevent the accumulation of dirt thereon. Step holes shall have a minimum tread of five inches and a minimum width of 14 inches. N. Enclosures. Pools shall be surrounded with a fence, wall or other enclosure with a minimum height of four feet for the safety and control of patrons and spectators and the enforcement of pool regulations. Such barriers shall be impenetrable by toddlers and so installed as to afford no handholds or footholds. Self-closing and self-latching mechanisms shall be provided on gates, etc., at entranceways, and permanent locking shall be available for periods when the pool is closed. O. Sand area. Sand areas are not recommended. If provided, sand areas shall be separated from the pool and enclosed with a fence having a separate entrance and exit. The exit or return gate shall be provided with a shower and foot wash having continuous circulation. At least six inches of sand shall be provided. P. Lighting and electrical requirements. (1) Where underwater lighting is used, not less than 0.5 watt shall be employed per square foot of swimming pool surface area. Such lights shall be spaced to provide illumination so that all portions of the pool, including the bottom, may be readily seen without glare. (2) Area lighting shall provide at least 0.6 watt per square foot of deck area. If such lighting is used for night swimming, area and swimming pool lighting combined shall provide at least two watts per square foot of pool area, with two footcandles of illumination. (3) All electrical wiring shall conform to the National Electrical Code of the National Fire Protection Association, Article 680. (4) No overhead electrical wiring shall pass within 20 feet of the swimming pool enclosure.
Ask a question about Clifton law
Corpus searches the Clifton sections it holds and shows the ones that match, with their citations. Free, no sign-in.