§ 28-188 — Pretreatment of wastewater
Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Municipal Code § 28-188
Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/35a1188c-83d2-4839-a433-c11db640da6f
Sec. 28-188. - Pretreatment of wastewater.
(a) Pretreatment facilities. Users shall provide wastewater treatment as necessary to comply with this chapter and shall achieve compliance with all categorical pretreatment standards and requirements, local limits, and the prohibitions set out in subsection 28-187(a) within the time limitations specified by EPA, the state, or the utilities director, whichever is more stringent. Any facilities necessary for compliance shall be provided, operated, and maintained in proper order at the user's expense. Detailed plans describing such facilities and operating procedures shall be submitted to the utilities director for review, and shall be acceptable to the utilities director before such facilities are constructed. The review of such plans and operating procedures shall in no way relieve the user from the responsibility of modifying such facilities as necessary to produce a discharge acceptable to the city under the provisions of this article. (b) Additional pretreatment measures. A. Whenever deemed necessary, the utilities director may require users to restrict their discharge during peak flow periods, designate that certain wastewater be discharged only into specific sewers, relocate and/or consolidate points of discharge, separate sewage waste streams from industrial waste streams, and such other conditions as may be necessary to protect the POTW and determine the user's compliance with the requirements of this article. B. The utilities director may require any person discharging into the POTW to install and maintain, on their property and at their expense, a suitable storage and flow-control facility to ensure equalization of flow. An individual user discharge permit may be issued solely for flow equalization. C. Grease, oil, and sand interceptors shall be provided when, in the opinion of the utilities director, they are necessary for the proper handling of waste water containing excessive amounts of grease and oil, or sand; except that such interceptors shall not be required for residential users. All interception units shall be of a type and capacity approved by the utilities director, and shall comply with the city's Interceptor Ordinance No. [2489]. Interceptors shall be so located to be easily accessible for cleaning and inspection. Such interceptors shall be inspected, cleaned, and maintained in accordance with the ordinance by the user at their expense. D. Users with the potential to discharge flammable substances may be required to install and maintain an approved combustible gas detection meter. (c) Accidental discharge/slug discharge control plans. The utilities director shall evaluate whether each user needs an accidental discharge/slug discharge control plan or other action to control slug discharges. The utilities director may require any user to develop, submit for approval, and implement such a plan, or take such other action(s) that may be necessary to control slug discharges. Alternatively, the utilities director may develop such a plan for any user. An accidental discharge/slug discharge control plan shall address, at a minimum, the following: A. Description of discharge practices, including non-routine batch discharges; B. Description of stored chemicals; C. Procedures for immediately notifying the utilities director of any accidental or slug discharge, as required by subsection 28-191(f); and D. Procedures to prevent adverse impact from any accidental or slug discharge. Such procedures include, but are not limited to, inspection and maintenance of storage areas, handling and transfer of materials, loading and unloading operations, control of plant site runoff, worker training, building of containment structures or equipment, measures for containing toxic organic pollutants, including solvents, and/or measures and equipment for emergency response. (d) Hauled wastewater. A. Hauled waste water of a type authorized by the utilities director may be introduced into the POTW only at locations designated, and at such times as are established by the utilities director. Such waste shall not violate section 28-187 or any other requirements established by the city. The utilities director may require wastewater haulers to obtain individual user discharge permits or registration, and pay fees. B. The disposal of hauled industrial waste water containing hazardous wastes or pollutants in toxic amounts is prohibited. The discharge of hauled industrial waste is subject to all other requirements of this article. C. Industrial waste haulers may discharge loads only at locations designated by the utilities director, and no load may be discharged without prior consent. The utilities director may collect samples of each hauled load to ensure compliance with this article. Utilities director may require the industrial waste hauler to provide a waste analysis of any load prior to discharge. D. Industrial waste haulers must provide a waste-tracking manifests for every load. This form shall include, at a minimum, the name and address of the industrial waste hauler, permit number, truck identification, names and addresses of sources of waste, and volume and characteristics of waste. The form shall identify the type of industry, known or suspected waste constituents, and whether any wastes are RCRA hazardous wastes. E. The utilities director is authorized to charge fees for disposal of approved hauled wastes, and costs for any sampling and analysis of hauled loads that are needed to ensure compliance with this article.
(Ord. No. 2488, § II(3), 12-1-08)
Ask a question about Las Cruces law
Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.
