§ 17.04.710 — Appendix D—Fire Apparatus Access Roads — One- and Two-Family Residential Developments and Remoteness
Code of Ordinances of the City of Edmond, Oklahoma (Codified through Ordinance No. 4097, enacted August 10, 2026 (Supp. No. 40)) · Edmond Code of Ordinances tit. 17, § 17.04.710
Corpus is an independent public-information project, not the official City of Edmond website. Stable reference: corpuslaw.us/code/56f43175-3095-461f-8c49-c203e1d9c9f3
17.04.710 - Appendix D—Fire Apparatus Access Roads — One- and Two-Family Residential Developments and Remoteness.
IFC, Section D107 is hereby amended to read as follows: D107.1 One and two-family residential developments. Developments of one or two-family dwellings where the number of dwelling units exceeds 50 shall provide the fire apparatus access road to connect with future and existing developments, as determined by the fire code official. Developments of one and two-family dwelling where the number of dwelling units exceeds 99 shall be provided with two separate and approved fire apparatus access roads. Exceptions: 1. Where there are more than 50 dwelling units and all dwelling units are equipped with an approved automatic sprinkler system in accordance with section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the International Fire Code connection with future and existing developments and access from two separate and approved fire apparatus access roads shall not be required. 2. When all buildings are sprinklered throughout with an approved automatic sprinkler system, the distance between accesses may be reduced to one-third of the overall diagonal. D107.2 Remoteness. Where two fire apparatus roads are required, they shall be placed a distance apart equal to not less than one-half of the length of the maximum overall diagonal dimension of the property or area to be served, measured in a straight line between accesses. Exceptions. Where it is physically impossible to be one-half the diagonal dimension apart, the access road will be approved if the following conditions are met. 1. The two separate fire apparatus access roads must be separated as far as physically and practically possible and approved by the fire code official. 2. The two separate entrances must be a minimum of 325 feet apart measure in a straight line between accesses. 17.04.900 NFPA 72 National Fire Alarm Code, 2007 Edition. NFPA 72 Section 4.4.5 Exception 2 is hereby deleted without substitution.
(Ord. 3762, § 1, November 12, 2019; Ord. No. 3962, § 19, July 10, 2023). (Ord. 3365, § 2, December 10, 2012).
Ask a question about Edmond law
Corpus searches the Edmond sections it holds and shows the ones that match, with their citations. Free, no sign-in.