§ 38-43 — Water and wastewater requirements

Code of Ordinances of the City of Midwest City, Oklahoma (Codified through Ordinance No. 3615, enacted November 13, 2025. (Supp. No. 21)) · Midwest City Code of Ordinances § 38-43

Corpus is an independent public-information project, not the official City of Midwest City website. Stable reference: corpuslaw.us/code/5c1eff0b-0157-4fea-9d0f-0108ce8777fb

Sec. 38-43. - Water and wastewater requirements.

Sec. 38-43.1. Purpose statement. The water and wastewater infrastructure systems are two (2) of the most critical elements within any municipality. Water and wastewater are the fundamental service-based needs upon which cities are created to provide. The provision of municipal water for drinking water, landscaping irrigation, and a wide array of other purposes allows for the day-to-day residential and commercial activities to occur. Equally important to the public health, safety, and welfare of the city is the transmission and treatment of wastewater (also referred to as sanitary sewer). The wastewater system ultimately enables the city to provide a safe and clean environment for people to carry on their daily activities. Sec. 38-43.2. Water and wastewater basic policy. (a) Construction requirements. (1) Location of water and wastewater mains. All public water and wastewater mains shall be located within the street right-of-way or in easements in order to provide service to adjacent property. (2) Water easement and wastewater easement design. a. If water and wastewater mains are not located within the right-of-way, then an easement shall be dedicated. b. A water easement or wastewater easement shall be located along the frontage of the property, or as determined by the city engineer. c. All utility easements for water or wastewater shall be shown on the final plat for the specific purpose intended. d. Minimum easement width. 1. The minimum easement width for water or wastewater mains shall be fifteen (15) feet, or as determined by the city engineer. 2. Where it is necessary for water and wastewater facilities to be located within the same easement, the easement shall be a minimum of twenty (20) feet in width, or as determined by the city engineer. e. Encroachment on easement prohibited. No portion of a main or primary structure (including, but not limited to, swimming pools, walls, foundations, porches/patios and porch/patio covers, canopies, roof extensions/overhangs, chimneys, fire flues, etc.) shall encroach over or into any easement, except that wall-attached window awnings, "bay" style windows, and roof eaves shall be allowed to encroach into an easement a maximum of twenty-four (24) inches upon approval of the city engineer. (3) Relocation or replacement of an existing water or wastewater facility. When it is necessary to relocate or replace an existing water or wastewater facility to accommodate a proposed subdivision, the developer is responsible for all costs associated with the relocation, except as agreed to by the city council in a development agreement for oversizing a facility. (b) Construction plans. (1) Compliance required. Plans for construction of all water and wastewater facilities required by these regulations shall be prepared in accordance with the requirements and specifications contained in the Engineering Standards Manual and construction details and all applicable chapters of the Code of Ordinances (e.g., chapters 9, 13, 30, 37, and 43) which are incorporated by reference and made a part hereof. (2) Plan preparation and acceptance. Plans for the improvements must be prepared by a licensed engineer and accepted by the city engineer. (c) Acquisition of easements. The developer shall be responsible for the acquisition of all required off-site easements. Sec. 38-43.3. Preliminary utility plan. (a) Purpose and applicability. (1) Water and wastewater mains. Concurrent with the submission of a preliminary plat or minor plat not previously served by public utilities the developer shall submit a preliminary utility plan showing the location and size of water and wastewater mains, which will be required to provide adequate service and fire protection to the lots specified in the proposed plat. (2) Fire hydrants. Preliminary utility plans shall include plans and specifications for fire hydrant systems and shall be submitted concurrently with the submission of a preliminary plat or minor plat not previously or inadequately served by public fire hydrants, where hydrants are required. (b) Preliminary utility plan document. The preliminary utility plan shall be prepared as noted in the application form. Sec. 38-43.4. Miscellaneous requirements. (a) Construction over existing water or wastewater mains. No building shall be constructed over an existing water, wastewater, or lateral line. (b) Ownership and maintenance of water and wastewater mains. Ownership and maintenance of water and wastewater mains and service connections shall be regulated as follows: (1) Water utilities. a. All water mains and water meters constructed and installed, including water service connections located in a right-of-way or dedicated easement, shall be vested to the city. (2) Wastewater utilities. a. All wastewater lines constructed, including wastewater service connections located in a right-of-way or dedicated easement, shall be vested to the city. b. The developer, or single customer, shall be responsible for all maintenance of the wastewater service connections, unless replacement of the service is required under the roadway or pavement. When replacement under a roadway is necessary, the city shall be notified and approval granted from the city engineer prior to the replacement of service under the pavement. (c) No guarantee of availability of water supply or wastewater capacity. The city makes no guarantee that water supply or wastewater capacity will be available at any particular time or place. (d) Service lines prohibited from crossing adjacent lots. (1) Water or wastewater service lines shall not cross any adjacent lot. (2) The public main shall be extended so as not to require the service to extend across another lot. (3) Water and wastewater service lines shall be maintained by the property owner. (e) Adjacent to federal, state, or county roadways. Public water and wastewater mains adjacent to federal, state, or county roadways shall be constructed outside the right-of-way in a separate easement unless otherwise agreed by those agencies and the city. Sec. 38-43.5. Water. (a) Design and construction. (1) Installation of water facilities. a. Where water is to be provided through the city system, the property owner shall install adequate water facilities, including fire hydrants, in accordance with the following standards: 1. The city's Engineering Standards Manual and construction details; 2. The city's adopted fire code; and 3. Current applicable state regulations. b. If any such requirements conflict, the most stringent requirement shall apply. (2) Facilities for health and safety emergencies. a. All water facilities connected to the city's water system shall be capable of providing water for health and emergency purposes, including fire protection and suppression. b. Water supply facilities shall be in accordance with the Code of Ordinances and the Engineering Standards Manual and construction details. c. The design and construction of water system improvements and alternative water sources shall also comply with the following standards: 1. Design and construction of a water source on the site shall be in accordance with applicable state regulations. 2. Design and construction of water service from the city shall be in accordance with the standards in the city's Engineering Standards Manual and construction details. 3. Design and construction of a fire protection and suppression system shall be in accordance with the standards in the Engineering Standards Manual and construction details, and in accordance with the city's adopted fire code. (b) Location. (1) Shown on construction plans. The location and design of all fire hydrants, all water supply improvements and the boundary lines of special districts, private systems and certified water service areas, indicating all improvements proposed to be served, shall be shown on the construction plans. (2) Extension of water lines requirement. a. Extension of water lines shall be made along the entire frontage of the development adjacent to a street. b. If the subdivision is not adjacent to a street, the extension of water lines shall be accomplished in such a manner as to allow convenient future connections to said lines by new subdivisions. (3) Waiver for water line extension requirement. If new subdivisions will never be constructed beyond the developing subdivision due to physical constraints, the city engineer may approve a minor subdivision waiver for this requirement in accordance with section 38-59, Petition for subdivision waivers of this Subdivision Ordinance prior to action on the construction plans or prior to action on any plat. (c) Cost of installation. The cost of installing all water supply improvements to be made by the developer, including off-site improvements, shall be included in the performance guarantees. (d) Cost of extension. (1) Where the city's water distribution system is not planned to be extended in time to serve a proposed new development, all necessary water facilities to serve such development shall be provided by and at the expense of the developer. (2) If oversizing of a water facility is deemed necessary by the city engineer for future developments, then the city may participate in such oversizing costs as part of a development agreement. (e) Alternative water systems (water wells). Developments may be approved with alternative water facilities according to the following criteria and according to chapter 43 of the Midwest City Code: (1) Water well operation and quality shall meet the minimum state, county, and city requirements, when applicable. (2) Water wells may not be used for commercial sale of water. (3) If a residence is located within the city's required water connection service area, as regulated by the Code of Ordinances, that residence shall connect to the water service. Sec. 38-43.6. Wastewater. (a) Extension of and connection to the city's wastewater collection system. (1) Extension of wastewater system requirement. a. Extension of, and connection to, the city's wastewater (sanitary sewer) system shall be required for all new developments within the city's limits. b. The city is not in any way obligated to allow extension of municipal wastewater outside the city's limits. (2) Waiver for wastewater system extension requirement. The required extension of, and connection to, the municipal wastewater system may be waived as a minor subdivision waiver, in accordance with section 38-59 Petition for subdivision waivers, by the city engineer if the city engineer determines that such extension would require unreasonable expenditures and that an on-site wastewater disposal system (see subsection (e), On-site wastewater disposal systems) will function properly and safely. (b) Design and construction. (1) Gravity flow. a. It is the policy of the city to require all wastewater collection lines to have gravity flow. b. The use of lift stations and force mains is prohibited unless a gravity design is impractical, as determined by the city engineer. (2) Location, design and sizing. The location, design, and sizing of all wastewater improvements shall be shown on the construction plans and are subject to approval by the city engineer. (c) Cost of installation. The cost of installing all wastewater improvements to be made by the developer, including off-site improvements, shall be included in the performance guarantees. (d) Extension. (1) Cost of extension. a. Where the city's wastewater system is not planned to be extended in time to serve a proposed new development, all necessary wastewater facilities to serve such development shall be provided by and at the expense of the developer. b. If oversizing of a wastewater facility is deemed necessary by the city engineer for future developments, then the city may participate in such oversizing costs as part of a development agreement. (e) On-site wastewater disposal systems. (1) Cases where on-site wastewater disposal systems (OSWDS) are permitted. a. Pursuant to a waiver for wastewater system extension requirement (subsection (a)(2) above), if the city engineer determines that extension of and connection to the city's wastewater system is impractical (e.g., due to construction timing of the city's system) or not feasible and where the city engineer approves the use of an on-site wastewater disposal system(s); and b. Such on-site system(s) shall provide adequate wastewater disposal for all lots, tracts, parcels, and structures in the development that cannot be connected to the city's wastewater system. (2) OSWDS connection required after city's system is available. All properties and structures that are allowed to utilize an on-site wastewater disposal system shall, at the owner's expense or using funds escrowed by the developer, connect to the city's wastewater system when such municipal system is extended to the service area as determined by the city engineer. (3) Cases requiring existing system upgrades. In order to protect the public health, safety and welfare, an existing on-site wastewater disposal system shall be upgraded, or reconstructed if necessary, to comply with the city's standards by the owner, at the owner's expense, if the operation of the facility does not comply with government regulations or if it causes objectionable odors, unsanitary conditions, pollution, etc. (4) Compliance and application timing requirement. a. All on-site wastewater disposal systems shall be designed, permitted, constructed, operated, and maintained in compliance with all applicable local, county, and state regulations. b. A permit for such system shall be acquired prior to final plat approval. (5) Acreage requirement. In addition to being in agreement with Oklahoma Department of Environmental Quality (DEQ) requirements, each lot, tract, parcel and structure that utilizes an on-site wastewater disposal system shall have a minimum land area of at least one-half acre if on city water or three-fourth acre if not on city water. (6) Separation requirement from water wells. In addition to being in agreement with Oklahoma Department of Environmental Quality (DEQ) requirements, no portion of any on-site wastewater disposal system shall be constructed within a minimum one hundred and fifty-foot radius around any water well either on-site or on other properties. (7) Limitations for soil absorption systems. On-site wastewater disposal facilities requiring soil absorption systems may be prohibited where such systems will not function properly due to high ground water, flooding, unsuitable soil characteristics, or other topographical or environmental issue.

(Ord. No. 3180, § 2, 8-14-12; Ord. No. 3502, § 7, 1-10-23)

Ask a question about Midwest City law

Corpus searches the Midwest City sections it holds and shows the ones that match, with their citations. Free, no sign-in.