§ 38-54 — Retaining wall construction and easements
Code of Ordinances of the City of Midwest City, Oklahoma (Codified through Ordinance No. 3615, enacted November 13, 2025. (Supp. No. 21)) · Midwest City Code of Ordinances § 38-54
Corpus is an independent public-information project, not the official City of Midwest City website. Stable reference: corpuslaw.us/code/37fe8086-d761-437b-a97b-d9a694def885
Sec. 38-54. - Retaining wall construction and easements.
Sec. 38-54.1. Purpose statement. Retaining walls affect the public health, safety, and welfare in two (2) primary ways. First, retaining walls stabilize soil for land that has significant topography to allow for development activity to occur. The construction design of retaining walls must account for their perpetual operation and safety considerations. Second, retaining walls direct the flow of water and help prevent future drainage and soil instability problems. Preventing drainage and soil instabilities problems promotes quality subdivisions, which directly benefits homeowners and business owners by protecting their private property investments. This section (section 38-54) is designed to ensure the quality design and construction of retaining walls. Sec. 38-54.2. Applicability. This section (section 38-54) applies to all retaining walls constructed within five (5) feet of a property line or a proposed property line within a subdivision of land. Sec. 38-54.3. Construction. (a) Retaining wall location. (1) Retaining walls shall be located and constructed on private property and shall not be within any existing or planned right-of-way. (2) A retaining wall shall be located entirely on one (1) lot and shall not straddle property lines, as shown in Figure 49: Retaining Wall Diagram. A retaining wall may stretch across several private properties as long as each portion of the wall is clearly indicated as being a part of the associated private property. (b) Retaining wall height standards. (1) Any earth terracing method or wall that supports a structure or vehicle load shall meet the requirements of this section. (2) A retaining wall shall meet city design standards. Any proposed alternative design shall be submitted to the city engineer for approval prior to its construction. (3) All retaining walls shall be constructed from masonry or concrete materials. (4) In lieu of constructing a required retaining wall, an alternative plan to a retaining wall installation may be submitted to the city engineer for approval. The plan must meet all of the drainage requirements for a property as noted on the preliminary plat drainage plan. (c) Timing of retaining wall construction. (1) All retaining walls shown on the grading plan/preliminary plat (see subsection (d) below) that cross multiple properties shall be installed prior to approval of the final plat. (2) Alternative timings to installing retaining walls prior to final plat may be approved by a major subdivision waiver (see section 38-59 for major subdivision waivers). (d) Grading plan requirement. (1) A retaining wall shall be constructed in accordance with the grading plan approved with the preliminary plat and shall comply with the requirements of the applicable building code and this subdivision ordinance. (2) Any change from the approved grading plan or design for a retaining wall within a subdivision shall not be permitted unless the applicant has submitted plans for the entire subdivision showing the proposed changes in grading and the city engineer has approved the proposed change(s). (e) Drainage/stormwater runoff requirement. (1) A retaining wall shall be designed and constructed to prevent drainage/stormwater runoff from spilling over the top of the retaining wall and onto adjacent properties. (2) The city engineer shall require all retaining walls within a side yard to be designed and constructed up to a height two (2) inches below the finish floor elevation, which shall be shown on the plat (see Figure 49: Retaining Wall Diagram). Sec. 38-54.4. Retaining walls required based on the city engineer and grading plans. (a) Required retaining walls. As required by the city engineer, if the grading plans submitted with the preliminary plat application indicate a need for the construction of one (1) or more retaining walls, the location of the retaining wall(s), private retaining wall easement(s) (if applicable), and no-build zone(s) (if applicable) shall be shown on the preliminary plat and final plat. (b) Optional retaining walls. The developer may install retaining walls not required by the city engineer if the retaining walls are shown on the grading plans and approved with the preliminary plat application indicating, the location of the retaining wall(s), private retaining wall easement(s), (if applicable), and no-build zone(s). Sec. 38-54.5. Retaining wall design on single lots. The retaining wall contained within one lot shall be designed with the following elements: (a) Private retaining wall easement for the neighboring property. (1) The developer shall dedicate a private retaining wall easement on the neighboring property to the property with the retaining wall. The private retaining wall easement will allow the future property owner to access, maintain, and repair the retaining wall from the neighboring property. (2) The width of the private retaining wall easement shall be five (5) feet from the bottom (i.e., the point where the retaining wall meets the lowest point of the ground) of the retaining wall. (3) See Figure 49: Retaining Wall Diagram. (b) No build zone of the property with the retaining wall. (1) If necessary or requested by the city engineer, the developer shall indicate a no-build zone on the property with the retaining wall. The no-build zone is intended to help protect the integrity retaining wall. No structures or swimming pools shall be built in the no-build zone. (2) The width of the no-build zone shall be established by the applicant's structural professional engineer (P.E.) and is subject to the approval of the city engineer. (3) See Figure 49: Retaining Wall Diagram. Sec. 38-54.6. Retaining wall maintenance responsibilities. The property owner or the homeowners' association (HOA) for the subdivision, as applicable, shall be responsible for maintenance of the retaining wall and a note may be included to this effect on the final plat. Figure 49: Retaining Wall Diagram [image omitted; see the official code]
(Ord. No. 3180, § 2, 8-14-12; Ord. No. 3246, §§ 1-3, 9-8-15)
Ask a question about Midwest City law
Corpus searches the Midwest City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
