§ 32-280 — Binder

Code of Ordinances, City of Chattanooga, Tennessee (Supp. No. 40: codified through Ordinance No. 14374, enacted June 16, 2026) · Chattanooga City Code § 32-280

Corpus is an independent public-information project, not the official City of Chattanooga website. Stable reference: corpuslaw.us/code/77f64bde-4af1-4ff3-af30-7a7db3ed4789

Sec. 32-280. - Binder.

(a) Contractors must contact the Geotechnical Engineer prior to beginning the binder course installation. This is imperative or the work may not be accepted. ..... (b) The binder asphalt shall be placed over the prime coat. The binder asphalt shall be compacted to an average density of at least ninety-two percent (92%) of the theoretical maximum density as determined by the Marshall method (fifty (50) blows), with no individual test less than ninety percent (90%). The theoretical maximum density shall be provided by the asphalt binder supplier. The Geotechnical Engineer will test the thickness and compaction by obtaining cores every five hundred (500) feet, or a minimum of three (3) cores. If any area does not meet the minimum thickness or compaction requirements, additional cores will be taken at one hundred (100) foot intervals until two consecutive cores meet the requirements. Areas that do not meet the requirements shall be removed and replaced. As an option, the Geotechnical Engineer can be present during construction to check the laydown thickness and temperature of the asphalt and to conduct nuclear density tests after compaction. In this case, coring will be reduced to three (3) cores or one (1) every two thousand (2,000) feet. In any case, a minimum of three (3) cores will be required. ..... (c) The binder asphalt shall meet the requirements of TDOT standard specifications section 307. Either 307B, 307BM or 307BM-2 mixes may be used. The minimum binder design thickness shall be in accordance with the City of Chattanooga Standard Drawings. . ..... (d) Binder thickness tolerances. The average thickness of the binder shall be greater than or equal to the design thickness, with no individual test more than one-quarter (¼) inch less than the design thickness. Areas deficient in thickness shall be evaluated by additional coring at one hundred (100) foot intervals to determine the area of deficient thickness. The deficiency may be corrected by increasing the thickness of the surface asphalt. .....

(Ord. No. 11451, § 1, 9-2-03; Ord. No. 11882, § 1, 9-5-06; Ord. No. 14093, § 1, 3-12-24)

Ask a question about Chattanooga law

Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.