§ 3.2.11.6 — Special Provisions for Flood Hazard Reduction in Areas of Special Flood Hazard
Code of Ordinances of the City of Abilene, Texas (Supp. No. 15: codified through Ordinance No. 85-2026, enacted September 24, 2026) · Abilene Code of Ordinances § 3.2.11.6
Corpus is an independent public-information project, not the official City of Abilene website. Stable reference: corpuslaw.us/code/ce22c712-5212-4c85-bc84-bc6a99f7bbb2
Section 3.2.11.6 - Special Provisions for Flood Hazard Reduction in Areas of Special Flood Hazard
(a) General Standards. In all areas of special flood hazards, the following general provisions shall prevail: (1) All new construction or substantial improvements shall be designed (or modified) and adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; (2) All new construction or substantial improvements shall be constructed by methods and practices that minimize flood damage; (3) All new construction or substantial improvements shall be constructed with materials resistant to flood damage; (4) All new construction or substantial improvements shall be constructed with electrical, heating, ventilation, plumbing, and air-conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; (5) All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system; (6) New and replacement sanitary sewer systems shall be designed to minimize or eliminate infiltration of floodwaters into the system and discharge from the systems into floodwaters; (7) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding; and (8) All applicable building codes of the City of Abilene. (b) Specific Standards. In all areas of special flood hazards where base flood elevation data has been provided as set forth in this Division, the following provisions are required. (1) Residential Construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated to one foot (1') above the base flood elevation or eighteen inches (18") above the gutter whichever is most restrictive. For a hillside lot in an area of special flood hazard, the eighteen (18) inch above gutter requirement may be waived by an approved Drainage Plan prepared by a registered professional engineer that demonstrates that the residence is safe from flooding. A registered professional engineer, architect or land surveyor shall submit a certification in the specified format to the City Engineer that the standard of this subsection is satisfied. Such certification shall include both the elevation relative to base flood and the elevation relative to the gutter or that the construction conforms to the approved Drainage Plan. (2) Nonresidential Construction. New construction and substantial improvements of any commercial, industrial, or other nonresidential structure shall either have the lowest floor (including basement) elevated to one foot above the base flood level or, together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer, architect or land surveyor shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection. A record of such certification which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed shall be maintained by the Floodplain Administrator. (3) Enclosures. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. A minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding shall be provided. b. The bottom of all openings shall be no higher than one foot (1') above grade. c. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (4) Manufactured Homes. a. Require that manufactured homes or manufactured homes used commercially that are placed or substantially improved within Zones A1—30, AH, AE, and AO on the community's FIRM on sites: 1. Outside of manufactured home parks or subdivisions, 2. In a new manufactured home park or subdivision, 3. In an expansion to an existing manufactured home park or subdivision, or 4. In an existing manufactured home park or subdivision on which a manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as a result of a flood be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated one foot above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. b. Require that manufactured homes or manufactured homes used commercially to be placed or substantially improved on sites in an existing manufactured home park or subdivision within Zone A, A1—A30, AH and AE, and on the community's FIRM that are not subject to the provision of Subsection (b)(4)a above be elevated so that either: 1. The lowest floor of the manufactured home is one foot (1') above the base flood elevation, or 2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. c. Require that manufactured homes or manufactured homes used commercially to be placed on substantially improved sites in an existing manufactured home park or subdivision within Zone AO on the community's FIRM that are not subject to the provisions of Subsection (b)(4)a above be elevated so that either: 1. The lowest floor of the manufactured home is at the zone depth number, or 2. The manufactured home chassis supported by reinforced piers or other foundation elements or at least equivalent structures that are not less than 36 inches in height above grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. d. All manufactured homes shall be in compliance with Subsections (b)(4)a, (b)(4)b, and (b)(4)c, or shall be eighteen inches (18") above gutter, whichever is more restrictive. e. Require that all manufactured home parks located within flood-prone areas as defined on the community's FIRM develop a plan for evacuating residents of said parks [and such plan shall] be filed with the City's Emergency Management authorities within ninety (90) days of the passing of this ordinance. f. Require that recreational vehicles placed on sites with Zones A1—30, AH, AE and AO on the community's FIRM either: 1. Be on the site for fewer than one hundred and eighty (180) consecutive days, or 2. Be fully licensed and ready for highway use, or 3. Meet the permit requirements of Subsection (b)(4)a, (b)(4)b, or (b)(4)c. A recreational vehicle shall be considered ready for highway use if it is on its own wheels or jacking system, is attached to the site only by quick-disconnect type utilities and security devices and has no permanently attached additions. g. Require that manufactured homes or manufactured homes used commercially placed or substantially improved on sites in an existing manufactured home park or subdivision or outside of a manufactured home park or subdivision which lies within the floodway as designated on the community's floodway map must meet the requirement of Subsection (b)(5) below. h. Require owners of mobile homes located in areas of special flood hazard to sign before a Notary Public a form prepared by the City that acknowledges that the mobile home is located in a flood hazard area, that the mobile home is subject to damage during a flood and that federal flood insurance is available. (5) Floodways. Located within areas of special flood hazard established in 3.2.11.2(b) [3.2.11.2(e)] are areas designated as floodways. Since the area chosen for the regulatory floodway must be designated to carry the waters of the base flood without increasing the water surface elevation of that flood more than one foot (1') at any point; and since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles and erosion potential, the following provisions shall apply: a. Encroachments, including fill, new construction, substantial improvements, earth changes and other developments will not be permitted except when an approved Floodway Development Permit has been secured demonstrating that the proposed encroachment: 1. Will not result in any increase in flood levels within the community during the occurrence of the base flood discharge; and 2. Is consistent with the Abilene Stream Management Plan and Abilene Drainage Standards; and 3. Meets the standards of this ordinance and specifically Section 3.2.11.5, Floodway Development Permits, and Section 3.2.11.6 Special Provisions for Flood Hazard Reduction in Areas of Special Flood Hazard. b. The following are exempt from the requirements in above Subsection (b)(5)a: 1. Bona fide agricultural and farming operations which constitute the principal use of any lot or tract of ground in the City of Abilene and which meet the requirements of the zoning regulations in Chapter 2 and Chapter 4 of this LDC. 2. Customary and incidental routine ground maintenance, landscaping and home gardening which does not require a zoning amendment, a zoning variance or a building permit, and which does not affect stormwater drainage through the site. 3. Certain parks and recreational uses which do not affect stormwater drainage through the site. 4. Emergency repairs of a temporary nature made on public or private property which are necessary for the preservation of life, health, or property and which are under such circumstances where it would be impossible or impracticable to obtain a Floodway Development Permit. 5. Excavation for the purpose of constructing, installing, maintaining or repairing any public street, public utility facility or any service lines related thereto. 6. Improvements consistent with the Abilene Stream Management Plan and Abilene Drainage Standards. (6) Standards for Areas of Shallow Flooding (AO Zones). Located within the areas of special flood hazard established in Section 3.2.11.2(b) [3.2.11.2(e)] are areas designated as shallow flooding. These areas have special flood hazards associated with base flood depths of one (1') to three feet (3') where a clearly defined channel does not exist and where the path of flooding is unpredictable and indeterminate; therefore, the following provisions apply: a. All new construction and substantial improvements of residential structures have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM (at least two feet (2') if no depth number is specified). b. All new construction and substantial improvements of nonresidential structures: 1. Have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as the depth specified in feet on the community's FIRM (at least two feet (2') if no depth number is specified), or 2. Together with attendant utility and sanitary facilities be designated [designed] so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects on buoyancy. c. A registered professional engineer, architect, or surveyor shall submit a certification to the Floodplain Administrator that the standards of (6)a, and (6)b.1 of this subsection are satisfied. d. A registered professional engineer, architect, or surveyor shall submit a certification to the Floodplain Administrator that the standards of (6)b.2 of this subsection are satisfied. e. Require within Zones AH and AO, adequate drainage paths around structures on slopes, to guide floodwaters around and away from proposed structures.
(Ord. No. 8-2010, pt. 1(Exh. A), 4-22-10; Ord. No. 12-2010, pt. A (Exh. A), 6-10-10)
Ask a question about Abilene law
Corpus searches the Abilene sections it holds and shows the ones that match, with their citations. Free, no sign-in.