§ 2.01 — Backflow Prevention Assembly Requirements
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Backflow Prevention Chapter, § 2.01
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/ee6adab8-772d-4fde-bbda-09b5c1e16007
Section 2.01 Backflow Prevention Assembly Requirements
A. The Regulatory Authority shall determine the type and location of backflow prevention assembly to be installed within the area served by the City. B. The use of a backflow prevention assembly at the service connection shall be considered as additional backflow protection and shall not negate the use of backflow protection on internal hazards as outlined and enforced by the Plumbing Code. C. At a minimum, a backflow prevention assembly shall be required in the following circumstances: 1. When the nature and extent of any activity at a premises, or the materials used in connection with any activity at a premises, or materials stored at the premises could contaminate or pollute the potable water supply. 2. When a premises has any one (1) or more cross-connections. 3. When internal cross-connections are present that are not correctable. 4. When intricate plumbing arrangements are present that make it impractical to ascertain whether cross-connections exist. 5. When a premises has a repeated history of cross-connections being established or re-established. 6. When entry to a premises is unduly restricted so that inspections for cross-connections cannot be made with sufficient frequency to assure that cross-connections do not exist. 7. When materials are being used such that if a backflow should occur, a health hazard could result. 8. When installation of an approved backflow prevention assembly is deemed by the Regulatory Authority to be necessary to protect the water supply of the City from contamination or pollution. 9. When an appropriate cross-connection survey report form has not been filed with the Regulatory Authority. 10. When a fire sprinkler system is connected to the City's water system. 11. In all new nonresidential construction there shall be installed an approved backflow prevention assembly at the service connection. The type of backflow prevention assembly required will be commensurate with the degree of hazard as determined by the Regulatory Authority in order to protect the water supply of the City from contamination or pollution. 12. When a building is constructed on commercial premises, and the end use of such building is not determined or could change, a reduced pressure principle backflow prevention assembly shall be installed at the service connection to provide protection of the public water supply in the event of the most hazardous use of the building. 13. When a premises is required to have backflow prevention assemblies, but water cannot be turned off during the testing of such assemblies, the premises shall be equipped with dual backflow prevention assemblies of the same type so that testing, repair and maintenance can be performed. 14. Any used water return system. 15. When a point-of-use assembly has not been tested or repaired as required by this Chapter, a premise isolation assembly shall be required. 16. When the Regulatory Authority determines that additions or alterations have been made to the plumbing system without the proper permits as required by the Plumbing Code, premises isolation shall be required. 17. All multistory buildings or any building with a booster pump or elevated storage tank. 18. Retrofitting shall be required on all high hazard connections and on all other connections where the Regulatory Authority deems it necessary to retrofit in order to protect the water supply of the City from contamination or pollution. 19. When reclaimed water is supplied to the site, an RPZ shall be installed on the potable water supply just inside the property line and before any branch connections and a double check backflow device shall be installed on the reclaimed water supply just inside the property line and before any branch connections. D. A person commits an offense if the person owns or is in control of any premises and fails to install and maintain backflow prevention assemblies on said premises as required by this section. E. A person commits an offense if the person owns, operates or manages any premises and backflow from the premises enters the public water supply system.
(Amend Ord 11-018, 3/22/11)
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.