Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Backflow Prevention Chapter, § 2.07
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/20e4fe3a-319b-4380-8cf1-98c56ac85843
Section 2.07 Fire Protection Systems
A. A double check valve assembly (DCVA) approved by the Regulatory Authority shall be the minimum protection required for fire sprinkler systems using piping material that is not approved for potable water use and/or that do not provide for periodic flow-through during each twenty-four-hour period, unless a variance has been issued in writing from the Regulatory Authority. A reduced pressure principle assembly (RPZ) shall be installed when any solution other than potable water can be introduced into the sprinkler system, unless an air gap is used to protect a tank supplying the system. B. A single detector check is required to be installed on all fire systems which are connected to the water system. Vaults are required to be used for installation of backflow valves on fire suppression systems. All backflow valves/vaults used on fire suppression systems shall be located as close to the right-of-way as possible, but shall be located no further than one hundred (100) feet from the property line. If the backflow valve can be installed inside the building, and remain within one hundred (100) feet of the property line, the valves may be installed inside the building. Only the Director of Water Utilities shall by written approval grant a variance to the distance requirement. C. Upon the approved installation of the DCVA, RPZ or approved backflow prevention assembly, a licensed fire line tester shall complete a cross-connection test report and submit the completed report to the Regulatory Authority as required by this Chapter. D. All fire line equipment, including piping and valves shall be installed by a state licensed fire sprinkler system contractor. Backflow prevention assembly testers may test and repair assemblies on fire lines only if they are permanently employed by an approved fire line contractor. The State Fire Marshall’s office requires that any person performing maintenance on fire lines shall be employed by an approved fire line contractor.
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.