Sec. 40-249. - Protection required; installation.
(a) The backflow prevention assembly protection which is required under this division shall be any of the USC FCCCHR recognized and approved backflow prevention assemblies, or as approved by the City. The City, prior to installation, must have approved each backflow prevention assembly. Failure to obtain such approval prior to installation of the backflow prevention assembly may result in the backflow prevention assembly failing to meet final approval by the City. The City shall determine the type and location of backflow assembly to be installed within the area served by the City. An assembly will be required in each of the following circumstances, but the customer is in no way limited to the following circumstances: (1) The nature and extent of any activity of the premises, or the materials used in connection with any activity of the premises, or materials stored on the premises, if said activity or material could contaminate or pollute the potable water supply. (2) Premises having any one or more cross-connections and the cross-connection is protected by an atmospheric vacuum breaker device (AVB). (3) Internal cross-connections are present that are not correctable. (4) Intricate plumbing arrangements are present which make it impractical to ascertain whether cross-connections exist. (5) There is unduly restricted entry so that inspections for cross-connections cannot be made with sufficient frequency to ensure that cross-connections do not exist. (6) Installation of an approved backflow prevention assembly is deemed to be necessary to accomplish the purpose of these regulations in the judgment of the City. (7) An appropriate cross-connection survey report form has not been filed with College Station Utilities upon request of the City. (8) A fire suppression system that is connected to the City's water system. (9) All new construction if deemed necessary in the customer service inspection. The type of assembly required will be determined by the degree of hazard. (10) When a building is constructed on commercial premises, and the end use of such building is not determined or could change, a reduced pressure principle backflow prevention assembly may be installed at the service connection that supplies water for public domestic use. (11) Any used water return system. (12) In the event a point-of-use assembly has not had the testing or repair done as required by this division, a premises isolation assembly will be required. (13) If it is determined that additions or alterations have been made to the plumbing system without obtaining proper permits, premises isolation may be required. (14) All multistory buildings or any building with a booster pump or elevated storage tank. (15) Retrofitting will be required on all high hazard connections and wherever else the City deems necessary to meet the intent of this division. (b) All backflow prevention assemblies installed after the effective date of the ordinance from which this division is derived shall be installed in a manner designed to facilitate ease of inspection and testing by the City or its chosen representative. Any currently installed backflow prevention assemblies which are located in inaccessible locations or where the tester is subject to physical danger shall be relocated to approved locations.
(Code 2011 (Repub.), § 11-10(E))
Ask a question about College Station law
Corpus searches the College Station sections it holds and shows the ones that match, with their citations. Free, no sign-in.