Sec. 40-250. - Testing/inspection of devices and assemblies.

(a) The City shall require all backflow prevention devices and assemblies to be both field inspected and tested in each of the following circumstances: (1) Immediately after installation. (2) Whenever the device or assembly is moved. (3) A minimum of once a year for all commercial applications other than lawn irrigation systems. (4) For premises that have been vacated and unoccupied for one year, prior to re-occupancy. (5) Immediately after repairs. (6) Once every five years for residential and commercial lawn irrigation systems. The AVB shall be excepted from the requirement in this subsection that such device be both field inspected and tested. The City shall require that the AVB be field inspected in each of the circumstances listed in this subsection. (b) All assembly testing shall be performed by a State certified backflow prevention assembly tester, approved by the City. (c) Duly authorized employees of the City bearing proper credentials and identification are entitled to enter any public or private property at any reasonable time for the purpose of enforcing this division. Persons and occupants of premises which are provided water service by the City, either directly or indirectly, shall allow the City or its representatives ready access at all reasonable times to all parts of the premises for the purposes of inspection, testing, records examination, or in the performance of any of its duties. Where persons or occupants of premises have security measures in force which would require proper identification and clearance before entry into their premises, the persons and occupants of the premises shall make necessary arrangements with their security guards so that upon presentation of suitable identification, personnel from the City will be permitted to enter, without delay, for the purposes of performing their specific responsibilities. (d) The City is not liable for damage to a backflow prevention assembly which may occur during testing. (e) The City may cause a water use survey to be conducted at any establishment located in the City which is served by a public water supply or which provides water to the public. Upon determination by the City that the establishment falls under the provisions of this division and requires a backflow prevention assembly, the City shall issue a notice to abate the condition or order the establishment to install the proper backflow prevention assembly. (f) It is the responsibility of any person who owns or controls property to have all assemblies tested annually in accordance with this section. Assemblies may be required to be tested more frequently if the City deems necessary. (g) All results from assembly testing by a certified backflow prevention assembly tester shall be placed on a form that has been approved by the City.

(Code 2011 (Repub.), § 11-10(F))

Ask a question about College Station law

Corpus searches the College Station sections it holds and shows the ones that match, with their citations. Free, no sign-in.