Sec. 40-257. - Installation guidelines and requirements for backflow prevention assemblies.
To ensure proper operation and accessibility of all backflow prevention assemblies, the most current guidelines contained in the Manual of Cross-Connection Control, which is adopted hereto by reference and incorporated herewith, shall apply to the installation of these assemblies. Additionally, the following shall also be required: (1) All premises that require continuous, uninterrupted water service and are required to have a backflow assembly must make provisions for the parallel installation of assemblies of the same type so that testing, repair and maintenance can be performed. (2) The property owner assumes all responsibility for any damage resulting from installation, operation, and/or maintenance of a backflow assembly. The owner shall be responsible for keeping all backflow prevention assembly vaults reasonably free of silt and debris. (3) Upon completion of installation, the City shall be notified and all assemblies must be inspected and tested. All assemblies must be registered with the City and shall provide the date of installation, manufacturer, model, type, size, serial number of the backflow assembly, physical location and initial test report. (4) Assemblies must be sized and flow characteristics must be sufficient to provide an adequate supply of water and pressure for the premises being served. (5) Assemblies must be readily accessible for testing and maintenance and must be located in an area where water damage to building or furnishings would not occur from water discharge. The property owner assumes all responsibility for any damage caused by water discharge from an assembly. An approved air gap shall be located at the relief valve orifice of RP assemblies. (6) No part of a reduced pressure principle backflow prevention assembly shall be submerged in water or installed in a location subject to flooding. RPs are typically installed above grade in well-drained areas, but may be installed below grade (ground level) if a boresight drain to daylight is provided. The drain shall be of adequate capacity to carry the full rated flow of the assembly and shall be screened on both ends. (7) Reduced pressure principal detector backflow prevention assemblies (RPDA) may be utilized in all installations requiring a reduced pressure principal backflow prevention assembly and detector metering. a. RPDAs shall comply with the installation requirements applicable for reduced pressure principal backflow assemblies. b. The line-size RP assembly and the bypass RP assembly must each be tested. The certified tester must complete a separate test report for each assembly. (8) Vertical installations of DCs are allowed only on sizes up to and including four inches that meet all of the following requirements: a. Internally spring-loaded check valves. b. Flow is upward through assembly. c. Approved for vertical installation by the USC FCCCHR. d. Approved by the City. (9) Double check detector backflow prevention assemblies (DCDA) may be utilized in all installations requiring a double check valve assembly and detector metering. a. DCDAs shall comply with the installation requirements applicable for double check valve assemblies (DCs). b. The line-size DC assembly and the bypass DC assembly must each be tested. The certified tester must complete a separate test report for each assembly. (10) Pressure vacuum breaker backflow prevention assemblies (PVB) may be utilized as point-of-use protection against back-siphonage only and shall not be installed where there is potential for back-pressure. PVBs shall not be installed in an area subject to flooding or where damage would occur from water discharge. (11) Spill resistant pressure vacuum breaker backflow prevention assemblies (SVB) may be utilized in all installations requiring a pressure vacuum breaker. SVBs shall comply with the installation requirements applicable for pressure vacuum breaker backflow prevention assemblies.
(Code 2011 (Repub.), § 11-10(M))
Ask a question about College Station law
Corpus searches the College Station sections it holds and shows the ones that match, with their citations. Free, no sign-in.