For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7.2 — General Provisions

Code of Ordinances of the City of College Station, Texas (Supp. No. 10 Update 2: codified through Ordinance No. 2026-4726, adopted October 22, 2026) · College Station Land Development Ordinances, App. A, § 7.2

Corpus is an independent public-information project, not the official City of College Station website. Stable reference: corpuslaw.us/code/52dd661b-7ce1-418d-ac77-c87a2117d1cf

Sec. 7.2. - General Provisions.

A. Health and Environmental Safeguards. No machine, process, or procedure shall be employed on any property in the city, in which: 1. Emission of smoke, dust, or noxious, toxic, or lethal gases are detectable beyond the perimeter of the property; 2. Materials are stored or accumulated in such a way that they may be carried by rainwater in natural drainage channels beyond the limits of the property, which are noxious, toxic, radioactive, contain oil or grease, wood, cellulose fibers, hair, feathers, or plastic, or have a pH factor greater than ten (10) or less than five (5); 3. Vibration is discernible beyond the property line; or 4. Noise above the ambient noise level is discernible beyond the property line. B. Minimum Requirements. 1. No building plot shall have lower or less stringent standards or dimensions than those prescribed for respective zones in this UDO. 2. No building permit or development approval may be issued for a lot that does not meet the minimum lot area requirements of this UDO except as provided for in Article 9, Nonconformities of this UDO. 3. In the absence of public water or public sewer, no building permit shall be issued until the lot meets all applicable requirements of this UDO and the Texas Department of Health and Environmental Control. A septic system that has been approved by the Brazos County Health Department may be permitted if an exception to sewer service has been granted under the Water and Sewer Service Article of Chapter 40, Utilities of the City of College Station Code of Ordinances. 4. Utilities using land or an unoccupied building covering less than one thousand (1,000) square feet of site area shall be exempt from minimum lot area standards. C. Visibility at Intersections in all Districts. Within a departure sight triangle as defined by the current edition of the American Association of State Highway and Transportation Officials' (AASHTO) A Policy on Geometric Design of Highways and Streets, nothing shall be erected, placed, planted, or allowed to grow in such a manner that would obstruct the drivers' view at intersections. Sight triangles shall apply to street intersections, commercial driveways, and multifamily driveways. Obstacles prohibited include but are not limited to fences, walls, entry signage, structures, buildings, hedges, etc. However, fences, walls, and/or hedges that do not impair vision from three (3) feet to nine (9) feet above the curb may be permitted with the approval of the City Engineer. Required public use facilities such as fire hydrants, traffic signage, utility structures, etc. are exempted. D. Required Yards (Setbacks). 1. General Requirements. a. Setbacks are measured from the property line. b. On lots with approved rear access, the rear setback shall be measured from the nearest boundary of the access easement or alley. c. No structure that is taller than eight (8) feet in height and that has a roof structure that completely or partially blocks the view to the sky shall be located within the required setback area unless specifically allowed herein. d. No part of a yard or other open space required in connection with any building, building plot, or use for the purpose of complying with this UDO shall be included for any other building, building plot, or use as part of a yard or open space. e. Where an existing lot was created by an approved plat prior to July 15, 1970, and the property is designated as Neighborhood Conservation in the Comprehensive Plan Future Land Use & Character Map, a new (infill) single-family dwelling unit shall use the adjacent lots to determine the appropriate front yard setback. The new dwelling unit shall be set no closer to the street or farther back from the street than the nearest neighboring units. Areas zoned NPO Neighborhood Prevailing Overlay are exempt from this requirement. Setbacks for areas zoned NCO Neighborhood Conservation Overlay are stated in the specific rezoning ordinance for the area. 2. Reduction for Public Purpose. a. When an existing setback is reduced because of a recent or pending conveyance to a federal, state, or local government for a public purpose and the remaining setback is at least fifty (50) percent of the required minimum setback for the district in which it is located, then that remaining setback will be deemed to satisfy the minimum setback standards of this UDO. b. For the purposes of this Subsection, such conveyance shall have occurred within one (1) year immediately following submittal for site plan approval or be anticipated to occur within one (1) year of site plan approval. 3. Features Allowed Within Required Yards. The following features may be located within a required yard but may be subject to additional regulations applied herein: a. Trees, shrubbery, or other landscape features, excluding gazebos or other similar structures that require a building permit; b. Fences and walls; c. Driveways; d. Sidewalks; e. Utility lines, wires, and associated structures, such as power poles; f. Mechanical equipment, such as air conditioning units, pool pumps, and similar equipment; g. Uncovered porches, uncovered steps to building entrances, and uncovered patio decks; h. Covered porches that are open on three (3) sides, may extend up to six (6) feet, including eaves, into any required front or side street setback; i. Openwork fire balconies and fire escapes may extend up to six (6) feet into any required rear setback; j. Sills, belt courses, cornices, buttresses, chimneys, flues, eaves, and other architectural features may extend up to eighteen (18) inches into any required yard; k. Balconies or decks located more than eight (8) feet from the ground may project up to six (6) feet into the required front yard; l. Accessory structures that do not require building permits; m. Bus stops that offer shelter from the elements. Such shelters may be located within a front or side street yard. Shelters may be located within a public right-of-way if a private improvement in public right-of-way permit has been duly issued; and n. Swimming pools and hot tubs without shelter. E. More Than One (1) Principal Structure on a Lot or Parcel. 1. In any single-family, duplex, or townhouse zoning district, including MH Middle Housing, no more than one (1) structure housing a permitted principal use may be erected on a single lot or building plot. 2. In all other districts, more than one (1) structure housing a permitted principal use may be erected on a building plot. Yard and other requirements herein shall apply to the building plot. F. Fences/Walls. Fences of wood, chain-link, or similar material, and less than eight (8) feet in height, and walls of brick, stone, concrete, or similar material, and less than six (6) feet in height, shall not be construed to be structures, nor shall they require a building permit. G. Low-Density Residential Height Protection. 1. Purpose. The purpose of low-density residential height protection is to help mitigate the negative visual impacts of higher-density residential and non-residential uses on adjacent, low-density residential uses and districts. This is accomplished by regulating the height of such higher-density residential or non-residential uses when adjacent to low-density residential uses and districts. 2. Applicability. a. This Subsection shall apply to all multi-family structures, structures with shared housing uses, and non-residential structures to be constructed or reconstructed in any way that would increase the building height as defined in the Defined Terms Section of Article 11, Definitions of this UDO on property adjacent to a detached single-family, manufactured home park, or townhouse use or district. b. Unless otherwise stated in this UDO, the regulations herein shall not apply to any of the following: 1) Structures located in any of the NG Northgate design districts, RDD Redevelopment Districts, or P-MUD Planned Mixed-Use Development zoning districts; 2) Utility structures such as elevated water storage tanks and electrical transmission lines; 3) Individual architectural structures such as flagpoles, belfries, cupolas, spires, domes, monuments, chimneys, bulkheads, elevators, or chimney flues; or any other similar structure extending above the roof of any building where such structure does not occupy more than thirty-three (33) percent of the surface area of the roof; 4) Residential radio/television receiving antennas; 5) When the detached single-family, manufactured home park, or townhome use on the adjacent tract is nonconforming; 6) When the use on the adjacent tract is agricultural; 7) Developments designed to be mixed-use or that are within areas where it has been identified that redevelopment is appropriate, as shown on the Comprehensive Plan Future Land Use & Character Map. Such developments at the periphery of the mixed-use area or area identified as appropriate for redevelopment shall meet the terms of this Subsection, when applicable; or 8) When the developing property and all abutting properties are designated Mixed Residential on the Comprehensive Plan Future Land Use & Character Map, regardless of existing use or zoning. Unless otherwise excepted, the regulations herein shall apply to properties at the periphery of the Mixed Residential land use designation. 3. Slope Requirement. a. Multi-family and multiplex structures, structures with shared housing uses, and non-residential structures shall not be taller than fifty (50) percent of the linear distance from the property line that is shared with a single-family, manufactured home park, or townhouse use or district as illustrated by the inclined plane in the graphic below. When the adjacent lot is one dedicated by plat for detention or open area and is not buildable for a detached single-family house, manufactured home, residential amenity, or townhouse, the measurement shall be taken from the closest property line shared with a buildable detached single-family, manufactured home, or townhouse lot. Example of Low-Density Residential Height Protection [image omitted; see the official code] b. In addition to the height limitations set forth above in this subsection, the following additional height limitations apply in WC Wellborn Commercial zoning: 1) No building may exceed two (2) stories; 2) Maximum eave height shall be twenty-four (24) feet; 3) Maximum overall height to the peak of the roof shall be thirty-five (35) feet; 4) Any structure with an eave height over fifteen (15) feet will be constructed to resemble a two (2) story façade; 5) Buildings located closest to detached single-family, manufactured home park, or townhouse use or district and that are within fifty (50) feet of the property line are limited to one (1) story in height with an eave maximum of twelve (12) feet; and 6) An eave maximum of fourteen (14) feet in height is permitted when mechanical equipment is housed within a mezzanine. H. Public Address Systems. Public address systems shall not be audible to adjacent residential uses. I. Pedestrian Facilities. 1. In SC Suburban Commercial and WC Wellborn Commercial districts, pedestrian connections adjacent to residential areas shall be provided as determined by the Administrator to enhance pedestrian and bicycle mobility and connectivity. 2. In MU Mixed-Use districts, sidewalks that are a minimum of eight (8) feet wide shall be provided along all public rights-of-way, streets, and public ways adjacent to and within the development. 3. For sites subject to the Non-Residential Architectural Standards Section below except for MU Mixed-Use districts: a. Public entry façades of retail buildings that exceed two hundred (200) feet in horizontal length shall place a minimum ten (10) foot sidewalk along the full frontage of its public entry façade. Tree wells and planter boxes may be placed along this walkway in a manner that does not obstruct pedestrian movement. Bike parking facilities are allowed in this area. Vehicular parking or cart storage is prohibited. Outside display is allowed but only if it does not occupy more than thirty (30) percent of this area and meets the requirements of the Outside Storage and Display Section below. b. A site or sites that are part of a building plot over ten (10) acres shall provide designated connections among primary buildings and pad sites for pedestrian and bicycle traffic. Locations for sidewalks and bicycle parking facilities shall be provided and shown on the site plan. Pedestrian walkways may be incorporated into the landscape strips separating parking areas only if the strip is ten (10) feet in width. Pedestrian walkways shall be a minimum of five (5) feet wide and shall connect public street sidewalks, transit stops, parking areas, and other buildings in a design that ensures safe pedestrian use. c. A site or sites that are part of a building plot over ten (10) acres shall provide one (1) plaza developed as an integral part of the development and not less than five hundred (500) square feet in area. This area shall not count toward the required parking islands. This area shall incorporate a minimum of three (3) of the following: 1) Seating components; 2) Structural or vegetative shading; * 3) Water features; * 4) Decorative landscape planters; * 5) Public art; * 6) Outdoor eating accommodations; or 7) Hardscape elements at entrances and within the parking area such as decorative pavers, low masonry walls, clock towers, etc. * These public areas may be located within the parking landscape areas.

(Ord. No. 2023-4453, Pt. 1(Exh. A), 8-10-2023; Ord. No. 2023-4454, Pt. 1(Exh. C), 8-10-2023)

Ask a question about College Station law

Corpus searches the College Station sections it holds and shows the ones that match, with their citations. Free, no sign-in.