For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7.7 — Buffer Requirements

Code of Ordinances of the City of College Station, Texas (Supp. No. 10 Update 2: codified through Ordinance No. 2026-4726, adopted October 22, 2026) · College Station Land Development Ordinances, App. A, § 7.7

Corpus is an independent public-information project, not the official City of College Station website. Stable reference: corpuslaw.us/code/8a3a953b-01ef-4114-b483-873c51f5a753

Sec. 7.7. - Buffer Requirements.

A. Purpose. The purpose of buffer requirements, which generally include a buffer yard, plantings, and a fence or wall, is to provide a visual barrier between different zoning districts and to help mitigate any negative impacts of adjacent land uses on developed or developing properties. A buffer should visibly separate one (1) use from another and shield or block noise, glares, or other nuisances. B. Applicability. 1. Perimeter buffers shall be provided on building plots abutting developed or developing sites in accordance with the standards of this Section as set forth in the Minimum Buffer Standards Subsection below. The following shall provide buffers: a. Vacant sites that develop; b. Existing sites when additions, expansions, and/or redevelopments equal or are greater than twenty-five (25) percent of the existing improvements; c. Existing sites when cumulative additions, expansions, and/or redevelopments total twenty-five (25) percent or more of the existing improvements; d. Existing sites when a change of use intensifies the development in terms of elements such as traffic, processes, noise, water or air pollution, etc.; e. Existing sites with lawfully established nonconforming uses when the use is expanded; and f. Sexually oriented businesses. 2. Exceptions to the terms of this Section will be made when: a. The adjacent developed use is nonconforming; b. The adjacent developed use is agricultural; c. The Comprehensive Plan Future Land Use & Character Map designates the area as a Redevelopment Area; d. The property is zoned P-MUD Planned Mixed-Use District or PDD Planned Development District and the buffer requirement was determined through the rezoning process; e. The developing use is a primary or secondary educational facility containing a building with a Group "E" occupancy as defined in the International Building Code, as adopted; f. The developing property is in any of the NG Northgate design districts or RDD Redevelopment District; g. The required buffer yard is adjacent to FEMA designated one hundred (100) year floodplain or residential common area, with approval by the Administrator; or h. The developing property and all abutting properties are designated Mixed Residential or a more intense land use on the Comprehensive Plan Future Land Use & Character Map, regardless of existing use or zoning. Unless otherwise excepted, the regulations herein shall apply to properties at the periphery of the Mixed Residential land use designation. C. Relationship to Other Landscaping Standards. All buffer requirements shall be included on a development's landscaping plan. Landscaping provided to meet the buffer landscaping standards of this Section may not be counted towards meeting a project's landscape point requirements. The area of a site dedicated to a perimeter buffer shall not be included in calculating a site's minimum landscaping point requirements. D. Location. The buffer shall abut property boundaries shared with less intense uses or zoning districts as set forth in the Minimum Buffer Standards Subsection below. In the event a property abuts a less intense use and a less intense zoning district, the less stringent buffer shall be required along the shared boundary. E. Permitted Uses. 1. A buffer yard may be used for passive recreation or stormwater management. It may contain pedestrian, bike, or equestrian trails provided that: a. No plant material is eliminated; b. The total width of the buffer yard is maintained; and c. All other regulations of this Section are met. 2. No active recreation area, storage of materials, parking, driveways, or structures, except for approved pedestrian, bike, or equestrian trails and necessary utility boxes and equipment, shall be located within the buffer yard. 3. Pedestrian access through a perimeter fence or wall and buffer yard may be provided at the abutting resident's, owners association's, or the Administrator's option to provide convenient pedestrian access to non-residential uses such as commercial areas or schools. F. Minimum Buffer Standards. The buffer requirements are designed to permit and encourage flexibility in the widths of buffer yards, the number of plants required in the buffer yard, and opaque screens. Standard buffer requirements are depicted in the table below. The numbers shown are the required buffer widths. DEVELOPING USE (Classification) | ABUTTING PARCEL (a) (Use least restrictive of the zoning or the developed use.) Single-Family Residential (b) | Multi-Family Residential | Non-Residential (c) Single-family (b) | N/A | N/A | N/A Developments in MH Middle Housing | 2.5' for every 5' of building height (f) | N/A | N/A Structures with a shared housing use | 2.5' for every 5' of building height (f) | N/A | N/A Multi-family (c) | 10' (f) | N/A | N/A Office | 10' (f) | N/A | N/A Commercial (e) | 15' (g) | 10' (f) | N/A Industrial | 25' (g) | 15' (g) | 5' Developments in BP Business Park | 50' (g) | 15' (g) | 5' Developments in BPI Business Park - Industrial | 50' (g) | 30' (g) | 10' (d) Sexually oriented businesses | 50' (g) | 50' (g) | 50' (g) Notes: (a) When an abutting parcel is vacant and zoned R Rural, the Administrator shall use the land use classification of the property as designated on the Comprehensive Plan Future Land Use & Character Map in lieu of the zoning category in determining the buffer requirement. (b) Includes manufactured homes, mobile homes, manufactured home parks, duplexes in the D Duplex zoning district, and townhouses in the T Townhouse zoning district. (c) Includes commercial and other non-residential uses developed in the MF Multi-Family district. (d) When an abutting parcel is zoned BP Business Park or BPI Business Park Industrial, the buffer width shall be reduced to five (5) feet. (e) When a developing parcel is zoned WC Wellborn Commercial and adjacent to a single-family use, the buffer width shall be twenty (20) feet with a fence. (f) Shall include a fence. (g) Shall include a wall. 1. Buffer Yards. a. Buffer yards shall be measured from the common property line and may be located within established building setbacks. b. Where utility or drainage easements or other similar situations exists in the required buffer yard, the buffer yard may be reduced by the width of the easement; however, an additional five (5) feet may be required beyond the width of the easement in these situations to allow for the required plantings and fence or wall. All new plantings and irrigation shall be located outside of the easement. The Administrator has the discretion to allow a required fence or wall within the easement. c. In WC Wellborn Commercial: 1) Required buffer plantings shall be doubled along property lines adjacent to single-family residential zoning or land use. In lieu of a fence, plantings may be tripled. 2) When adjacent to single-family use, zoning, or designation on the Comprehensive Plan Future Land Use & Character Map, a buffer wall is required for the length of any adjacent parking, loading areas, or dumpster uses (including required maneuvering space). d. In BP Business Park, required buffer plantings shall be doubled along property lines adjacent to single-family residential zoning or development. e. In BPI Business Park Industrial, required buffer plantings shall be doubled along property lines adjacent to any zoning district or use other than BP Business Park or BPI Business Park Industrial. f. In MF Multi-Family and MU Mixed-Use, buffer yards shall only be required along the perimeter of the development, unless otherwise exempted in this Section. No buffer yards are required between uses contained within the development. 2. Plantings. a. If a fence or wall is not required per the table above, the following plantings shall be installed in the buffer yard: 1) A minimum of one (1) five (5) gallon shrub at a minimum of three (3) feet in height per three (3) linear feet of landscaping buffer; and 2) A minimum of one (1) two (2) inch caliper canopy tree per twenty-five (25) linear feet of landscape buffer. b. If a fence or wall is required per the table above, the following plantings shall be installed in the buffer yard, unless expressly provided for otherwise in this UDO: 1) A minimum of one (1) one and one-fourths (1.25) inch caliper non-canopy tree per fifteen (15) linear feet of landscaping buffer. The Administrator may allow the substitution of a minimum of one (1) five (5) gallon shrub at a minimum of three (3) feet in height per three (3) linear feet of landscaping buffer for the non-canopy tree requirement, or may require the substitution to mitigate potential negative impacts of a development; and 2) A minimum of one (1) two (2) inch caliper canopy tree per twenty-five (25) linear feet of landscape buffer. c. All buffer yard landscaping areas not dedicated to trees or shrubs shall be landscaped with grass, ground cover, or other appropriate landscape treatment in accordance with the Landscaping and Tree Protection Section above. d. Fifty (50) percent of all required shrubs within the buffer yard shall be evergreen. e. Plant materials shall show a variety of textures, colors, shapes, and other characteristics. Recommended buffer materials can be found in the Landscape & Streetscape Standards Section of the City of College Station Site Design Standards or those listed as appropriate for Zone 8 on the United States Department of Agriculture (USDA) Hardiness Zone Map. f. The arrangement of trees and shrubs in the buffer area shall be done in a manner that provides a visual separation between abutting land uses. Shrubs shall be massed in rows or groups to achieve the maximum screening effect. g. Irrigation is required for all new plantings. h. Existing vegetation may count toward the planting requirement if: 1) The vegetation is in good health and the landscape/streetscape plan verifies that it will meet the plantings criteria listed above (non-point trees may count towards a natural buffer); and 2) The vegetation is protected in accordance with the Landscaping and Tree Protection Section above. i. Plantings will not be allowed to encroach into a required visibility triangle for a public or private right-of-way except as set forth in the Visibility at Intersections in all Districts Subsection of the General Provisions Section above. 3. Fences and Walls. a. Fences may be solid wood or solid wood accented by masonry, stone, Exterior Insulation and Finish System (EIFS), or concrete columns. Walls may be masonry, stone, EIFS, concrete, or a combination of these materials, and shall be finished on both sides (framing not visible). Walls and masonry columns for fences must meet the footing standards prescribed by the International Building Code, as adopted, for such structures. b. Fences and walls shall be a minimum of six (6) feet in height and a maximum of eight (8) feet. Walls over six (6) feet must obtain a building permit. When the adjacent property and the buffer yard are at different elevations, the Administrator may require a greater fence or wall height to ensure adequate buffering. c. Fences and walls shall be placed within one (1) foot of the common boundary line when physically possible. In the event there is a physical constraint that will not allow the construction of a fence on the common boundary line (including but not limited to the existence of a creek, access easement, or existing vegetation), the Administrator may authorize an alternative fence location. d. Fences or walls will not be allowed to encroach into a required visibility triangle for a public or private right-of-way. 4. Substitutions. a. Existing natural vegetation may be used in lieu of plantings and a fence or wall under the following circumstances: 1) The existing vegetation consists of canopy and non-canopy trees which are shown through a tree survey to meet the minimum buffer planting requirements (non-point trees may be considered) and is of sufficient density to provide one hundred (100) percent opacity to a height of six (6) feet; and 2) The vegetation is protected in accordance with the Landscaping and Tree Protection Section above. b. Fences and walls may be substituted with a solid plant or hedge wall that is greater than six (6) feet in height with approximately one hundred (100) percent opacity. All shrubs planted for a hedge wall must be a minimum of fifteen (15) gallons each. The solid plant or hedge wall must be evergreen and may not be counted towards meeting the buffer planting requirement. c. Fences and walls may be substituted with a landscaped earthen berm if the combination of berm and landscaping is not less than six (6) feet in height from the elevation at the property line with approximately one hundred (100) percent opacity. The berm plantings must be evergreen and may not be counted towards meeting the buffer planting requirement. Berms must be a minimum of four (4) feet in height with a maximum slope of one (1) foot of height for every three (3) inches of width. Berms over six (6) feet in height shall have a maximum slope of four (4) feet of height for every one (1) foot of width as measured from the exterior property line. d. The required height of fences or walls may be reduced if used in combination with an earthen berm or a landscaped earthen berm if the height of the screening is six (6) feet from the elevation at the property line with approximately one hundred (100) percent opacity. The berm plantings must be evergreen and may not be counted towards meeting the buffer planting requirement. e. Walls may be substituted with fences if the required buffer yard area and plantings are doubled. f. Walls and fences may be omitted if the required buffer yard area and plantings are tripled. g. Walls and fences may be omitted if two (2) rows of evergreen plantings (minimum six (6) feet in height at the time of planting) are provided to create a solid screen along the common property line. h. Buffer plantings may be reduced by fifty (50) percent if providing a wall where a fence is required. G. Maintenance and Replacement. 1. Upon installation or protection of required landscape materials, appropriate measures shall be taken to ensure their continued health and maintenance. Required landscape areas and buffers shall be free of garbage and trash, weeds, pests, and disease. Required plant materials that do not remain healthy shall be replaced consistently with these provisions. 2. All landscaping materials and/or fences, walls, or berms shall be maintained by the owner(s) of the property that was required to install such landscaping materials and/or fences, walls, or berms under this Section. 3. Any canopy tree removed or otherwise destroyed by the willful act or negligence of the property owner, tenant, or contractor shall be replaced by a tree of the same or larger caliper. H. Appeals. 1. Appeals of the terms of this Section, with the exception of the Maintenance and Replacement Subsection above, shall be to the Design Review Board. 2. An appeal shall be made within thirty (30) days of the date of the notification of the decision by filing with the Administrator a notice of appeal specifying the grounds thereof. 3. The Design Review Board may authorize on appeal alternative buffer standards for a specific property or a waiver to this Section when such standards or variance will not be contrary to the public interest where, owing to unique and special conditions not normally found in like areas, strict enforcement of the provisions of the ordinance by the Administrator would result in unnecessary hardship, and so that the spirit of this Section shall be observed and substantial justice done.

(Ord. No. 2023-4453, Pt. 1(Exh. A), 8-10-2023)

Ask a question about College Station law

Corpus searches the College Station sections it holds and shows the ones that match, with their citations. Free, no sign-in.