For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13-505 — Gas well permit application and filing fees

Code of Ordinances, City of Grand Prairie, Texas (Supp. No. 117, Update 1: codified through Ordinance No. 1857-2026, adopted April 27, 2026) · Grand Prairie City Code § 13-505

Corpus is an independent public-information project, not the official City of Grand Prairie website. Stable reference: corpuslaw.us/code/0389a830-9bcf-4145-bdad-f51e6f85badf

Sec. 13-505. - Gas well permit application and filing fees.

(a) Every application for a gas well permit issued pursuant to this article shall be in writing signed by the operator, or some person duly authorized to sign on his behalf, and filed with the city. (b) Every application for a gas well permit shall be accompanied by the appropriate application form and permit fee. The following fees shall apply: Class 1 gas well permit fee per well .....$10,000.00 Class 2 gas well permit fee per well .....$7,500.00 Amended permit .....$1,500.00 Re-work fee (if required per subsection 13-504(d)) .....$1,000.00 Operator transfer per well .....$1,000.00 Annual fee (per permitted well) .....$2,750.00 Extension requests (per pad site or fracture pond) .....$10,000.00 The city, at its sole discretion, may elect to utilize a qualified third party to conduct any inspections required by this article or in response to complaints that require professional consultation or field sampling activities. Any fee charges by such third party inspector or the professional consultant shall be the responsibility of the operator and shall be paid to the city upon permitting to be held in escrow, or within thirty (30) days of receipt of an invoice from the city. Any permit that lapses for nonpayment of the annual permit fee required in this article will be reinstated upon payment of an additional fee of five hundred dollars ($500.00) for each thirty-day period in which the permit has been allowed to lapse. (c) The application shall include the following information: (1) The date of the application and type of gas well permit requested. (2) An accurate metes and bounds description of the leased pad site boundary enclosing the gas operation, the land parcel and the production unit. The name of the geologic formation as used by the commission shall also be included. Property recorded by plat should reference subdivision, block and lot numbers. (3) Map showing proposed transportation route and road for equipment, chemicals, or waste products used or produced by the gas operation. The map must contain the proposed location(s) of the directional signage at the exit of the pad site. (4) Proposed well name. (5) Surface owner names(s) and address(es) of the lease property. (6) Mineral lessee name and address. (7) Operator/applicant name and address and if the operator is a corporation, the state of incorporation, and if the operator is a partnership, the names and addresses of the general partners. (8) Name and address of individual designated to receive notice. (9) Name of representative with supervisory authority over all gas operation site activities and a twenty-four-hour phone number. (10) Location and description of all improvements and structures within one thousand feet (1,000) feet of the well. (11) Owner and address of each parcel of property within one thousand (1,000) feet of the proposed drill site. (12) A site plan of the proposed operation site showing the location of all improvements and equipment, including the location of the proposed well(s) and other facilities, including but not limited to, tanks, pipelines, compressors, separators, and storage sheds. (13) The name, address and twenty-four-hour phone number of the person to be notified in case of an emergency. (14) The exact and correct acreage and number of wells, if applicable, included in the gas well permit application. (15) Copies of all reports required by the commission. (16) A waste disposal plan to include disposal methods for drilling muds and cuttings, fracturing fluids, flowback water, produced water, solid waste, and any other materials from operations on the pad site. The plan must include treatment and disposal options considered. If a disposal or an injection method is included, submittal of a commission underground injection control permit number is required. If the plan includes disposal at an authorized landfill, a copy of the location and permit is required. (17) A description of public utilities required during drilling and operation. (18) A copy of the agreement with the owner/operator of the water source to be used during drilling and fracturing operations. (19) A copy of the approved commission permit to drill together with attachments and survey plats which are applicable to the drill and operation sites. All pooling certificates must be attached. (20) A copy of the determination by the state regulatory agency of the depth of useable quality groundwater. (21) Evidence of insurance and security requirements under this article. (22) A statement, under oath, signed by the operator, or designated representative, that the information submitted with the application is, to the best knowledge and belief of the operator or designated representative, true and correct. (23) All required application and gas well permit fees. (24) A copy of an erosion control plan pursuant to the city's design criteria and construction standards manual. (25) A copy of the hazardous materials management plan as required by the city's fire marshal's office. (26) A copy of an emergency response plan as required by the city's fire marshal's office. (27) A copy of a noise abatement study as required by the city's environmental services director. (28) A copy of a dust control plan as required by the city's environmental services director. (29) A copy of the driveway approach design and a copy of the permit application as required by the city engineer. (30) A copy of the private road design as required by the city engineer. (31) A site plan on an aerial map that indicates the distances of all applicable setbacks to structures, protected uses, freshwater wells, waterbodies, public streets, and all other applicable setbacks. (32) A copy of a contract with the city's authorized solid waste hauler. (33) A report detailing all private water wells within one thousand (1,000) feet of the pad site boundary and method for which such information was obtained. The failure to identify any nonregistered well will not be considered a violation of this article if the operator includes a private well information request as part of the well application notices required by this article. (34) A vector control plan that details all measures that will be taken to ensure that any fracture pond will not become a site for mosquito harborage. The plan shall list all planned measures for mosquito abatement activities, including any biological/chemical control applications or water level control measures. (35) A leak detection and compliance plan to ensure all site activities and equipment are in compliance with applicable rules and regulations. This plan should outline methodology to assess and evaluate the impact of drilling, fracturing, production, and other activities at the padsite and immediate surroundings. Specific elements shall include, but is not be limited to: A quarterly leak detection monitoring program, methods and equipment for emission measurements, and a response plan to address issues, if they arise, and any other information as required by the environmental services director. Monitoring shall include evaluation of potential impact to air, soil, surface water, or groundwater. Quarterly reporting of the monitoring results to the environmental services department is required with all laboratory data sheets, field logs, data summaries, and actions taken in the previous period. The plan must be created in accordance with the environmental services department guidelines. (36) A pipeline map indicating the location of the nearest gathering station and the alignment of the pipeline(s) connecting the operation site to the gathering stations. (37) Any other items required by the city's environmental services director.

(Ord. No. 9154-2011, § 1, 1-18-11)

Ask a question about Grand Prairie law

Corpus searches the Grand Prairie sections it holds and shows the ones that match, with their citations. Free, no sign-in.