Sec. 13-516. - Fences, walls and landscape screening.

(a) Fences/walls. Fences shall be required on drill sites during initial drilling, completion or reworking operations. All fencing and screening materials must be maintained in good repair at all times. A secured entrance gate shall be required. All gates are to be kept locked when the operator or his employees are not within the pad site boundary enclosure. Within one hundred twenty (120) days from setting the surface casing on the first well on a drill site, all gas well pad sites shall be completely enclosed with the required fence, trees, landscaping, and an operational landscape irrigation system as specified below in this article as follows: (1) Permanent enclosure requirements for a gas well pad site with no operations to be conducted within one thousand (1,000) feet of a protected use. a. A chain link shall be required for walls enclosing the gas well pad site, with said fence and support members being at least six (6) feet in height; b. Support posts shall be set in concrete and shall be imbedded into the ground to a depth sufficient to maintain the stability of the fence; provided, however, so long as stability of the fence is maintained, temporary fence posts shall not be required to be set in concrete; c. The chain link fabric shall be galvanized steel wire with a minimum plating of one and two-tenths (1.2) ounces of zinc per square foot of surface area and shall be coated with polypropylene or vinyl in a black color approved by the fire chief; d. The chain link fence fabric shall have a minimum thickness of 11-gauge; e. The chain link fabric shall be three and one-half-inch mesh; f. Posts and rails shall be standard galvanized, welded pipe, schedule 40 or thicker; provided, however, that nongalvanized drill pipe may be used if it exceeds schedule 40 in thickness; g. All pipe and other ferrous parts, except chain link fabric and drill pipe, shall be galvanized inside and outside with a plating which contains a minimum of one and two-tenths (1.2) ounces of zinc per square foot of surface area; h. Tension rods shall be three-eighths-inch round steel bolt stock. Adjustable tighteners shall be turnbuckle or equivalent having a six-inch minimum take-up. Tension bars shall have a minimum thickness of one-fourth by three-fourths-inch; and i. All fences shall have security extension arms at the top of such fences and such security extension arms shall be strung with at least two (2) strands of galvanized barbed wire. (2) Permanent enclosure requirements for a gas well pad site located within one thousand (1,000) feet of a protected use. a. All walls (either site constructed or prefabricated) shall be of kiln-fired masonry, stone or other like material, in whole or in part, and shall be constructed in accordance with standard engineering practices and shall meet the following specifications: 1. The wall shall be of a design compatible with the facilities, buildings and structures on and adjacent to the site; 2. The wall shall be at least eight (8) feet in height; and 3. The wall surface shall have a troweled, mortar bond finish for either brick or stone textures. b. Application of additional wall articulation and landscape buffering. Masonry wall enclosures required for the gas well padsite located within one thousand (1,000) feet of a protected use shall require wall adornments and landscaped features for each exterior side of the masonry wall enclosure, as measured between two (2) perimeter wall corners, through the application of either one (1) of two (2) options described in the following sections of this article. c. Wall plane articulation (Option 1). 1. For each exterior side of the masonry wall enclosure, a wall surface measuring no less than eight (8) feet in width shall be articulated, from top of wall to bottom of wall, in accordance with this section, with said articulated surface being spaced no more than fifty (50) feet, and no less than thirty (30) feet, apart from the next articulated surface, with each exterior side of the masonry wall enclosure containing at least three (3) such articulated surfaces. 2. One (1) or more of the following features shall be used to articulate the wall surface described in subsection (a)(2)c. above: Feature Description | Specification Wrought iron type grates. | To be installed into a void and open section of the wall with no grate openings greater than four (4) inches in width or diameter. Recessed niche. | To be recessed no less than eighteen (18) inches into the wall perimeter, as measured from the exterior wall surface, with planted shrubs inside the recessed wall niche areas. Masonry, stone and stucco shall be permitted materials for this feature. Projecting section. | To extend no less than eighteen (18) inches out from the wall perimeter, as measured from the exterior wall surface, with planted shrubs inside the recessed wall niche areas located between the projected wall sections. Masonry, stone and stucco shall be permitted materials for this feature. 3. Landscaping, maintenance and irrigation shall be required along the outside of the wall with suitable screening shrubs that complement the architectural character of the surrounding neighborhood. Screening shrubs shall be installed in between the articulated wall surfaces around the wall, or may be installed only within a recessed niche feature, as described subsection (a)(2)c.2. of this section, where such features are located. 4. Required screening shrubs shall be of an evergreen variety and be a minimum of three (3) feet in height at planting, with such landscaping being watered by an installed irrigation system that provides total water coverage to all plant materials. 5. The location of all landscaped improvements shall be depicted on the site plan drawing, or on an attaching sheet, of the gas well permit submittal documents. d. Vegetative concealment (Option 2). 1. Wall plane articulation, as described in subsection (a)(2)c. of this section, shall not be required for the vegetative concealment option. 2. Landscaping, maintenance and irrigation shall be required within a zone measured forty (40) feet outward from the exterior surface of all perimeter walls, with such landscaped zone to be dedicated and recorded as a "landscape and no-build easement", with such dedicated easement being permitted in lieu of the "well head easement" described in subsection 13-515(c) of this article. 3. The "landscape and no-build easement" may be filed as a separate instrument dedication, or be dedicated on a land subdivision plat approved by the city, and such "landscape and no-build easement" shall be dedicated and recorded with the appropriate agency of the county government in which the well is located prior to the commencement of drilling operations. 4. A berm with a minimum height of four (4) feet, as measured from the highest existing grade elevation of the gas well pad site, shall be required at the base of the masonry wall enclosure, with such berm having side slopes that shall not exceed a 3:1 slope. 5. Large evergreen screening shrubs, ornamental shrubs, groundcover, and bedding plants shall be planted around the perimeter of the masonry wall enclosure within the "landscape and no-build easement," with such landscape materials being planted in the following minimum quantities and sizes: Description | Specification Large evergreen shrubs. | Required to cover a minimum of forty (40) per cent of total easement area, and shall be a minimum of three (3) feet in height at planting, with such shrubs having the potential to grow to a mature height of a minimum of six (6) feet. Small ornamental shrubs. | Required to cover a minimum of twenty (20) per cent of total easement area, and shall be of a lower height compared to the evergreen shrubs, with such shrubs having the potential to grow to a mature height no greater than three (3) feet. Groundcover/bedding grasses. | Required to cover the balance plants and ornamental of total easement area. 6. All required shrubs and groundcovers may be planted anywhere within the required "landscape and no-build easement" and be of an approved species as listed in the landscaping and screening requirements of the Grand Prairie Unified Development Code as amended. 7. Trees shall be planted around the perimeter of the masonry wall enclosure within the "landscape and no-build easement" in a manner to achieve a more natural appearance. All required trees shall be of an evergreen variety, and be of an approved species as listed in the landscaping and screening requirements of the Grand Prairie Unified Development Code as amended. 8. The number of required trees to be planted shall equal one (1) tree for each twenty (20) linear feet of the total length of the masonry walled boundary. 9. A maximum of seventy percent (70%) of the required trees shall be at least three (3) inches in caliper diameter as measured six (6) inches above the root ball. 10. A minimum of thirty (30) per cent of the required trees shall be at least five (5) inches in caliper diameter as measured six (6) inches above the root ball. 11. All required trees may be planted anywhere within the required landscape and no-build easement. 12. Credit will be given for the preservation and maintenance of existing trees, inasmuch as the total number of trees, as required by this section in caliper inches, shall be reduced by the number of existing trees of equal or greater caliper inches that are preserved and maintained within the forty-foot wide "landscape and no-build easement". 13. All required landscaping should be kept in order, healthy, and be free of weeds and debris and must have an installed irrigation system that provides total water coverage to all plant materials. Upon written notification, any dead or deteriorated vegetation shall be removed and replaced within thirty (30) days from date of notification. 14. The location of all landscaped improvements shall be depicted on the site plan drawing, or on an attaching sheet, of the gas well permit submittal documents. e. A wrought iron type gate shall be required for both of the above-described options in accordance with the specifications contained in subsection (b)(2)b. of this section. (3) Gas well drilling/fracturing/development screening fence. All pad sites shall install a temporary screening fence prior to the commencement of drilling operations. The fence shall be a chain link fence with three and one-half-inch mesh. All pad sites within three hundred (300) feet of a public street shall install screening sections on any outer pad site boundary fence visible from the public street. The environmental services director may waive this screening requirement for any pad site boundary bordered by a boundary noise blanket or natural/vegetative/topographical screening. The screening fence shall be of such sufficient height to screen from view any portable buildings and/or supply areas. The temporary screening fence and the screening sections shall be depicted on the application site plan. The screening sections shall be composed of chain link fence covered with black colored closed mesh composed of polypropylene or vinyl. Alternative designs may be approved by the chief city planner. (b) Gate specifications. All chain link fences and masonry walls shall be equipped with at least one (1) gate. The gate shall meet the following specifications: (1) Each gate shall be not less than twelve (12) feet wide and be composed of two (2) gates, each of which is not less than six (6) feet wide, or one (1) sliding gate not less than twelve (12) feet wide. If two (2) gates are used, gates shall latch and lock in the center of the span; (2) The gates shall be constructed to a standard that meets the applicable specifications, or of other approved material that, for safety reasons, shall be at least as secure as a chain link fence; a. A chain link gate shall be required for any entrance to a gas well pad site with no operations within one thousand (1,000) feet of a protected use. b. A wrought iron type gate shall be required for any entrance to a gas well pad site located within one thousand (1,000) feet of a protected use. The gate shall have no openings greater than four (4) inches in width or diameter, and shall contain the following articulated features: 1. Articulated wall plane features, as described in subsection(a)(2)c. of this section, shall be required on each side of the gate, with such selected feature to be constructed with an elevated curvilinear profile extending no less than three (3) feet above the required wall height. Masonry, stone and stucco shall be permitted materials for this elevated feature. 2. For those walls constructed under the specifications described for "wall plane articulation" (Option 1), such elevated features shall qualify for, and be credited to, the wall plane articulation requirements specified in subsection (a)(2)c. of this section. 3. Such elevated profile features shall be required for all gate entrances. (3) The gates shall be provided with a combination catch and locking attachment device for a padlock, and shall be kept locked except when being used for access to the site; and (4) Operator must provide the city fire department with a "Knox padlock" or "Knox box with a key" to access the well site to be used only in case of an emergency.

(Ord. No. 9154-2011, § 1, 1-18-11)

Ask a question about Grand Prairie law

Corpus searches the Grand Prairie sections it holds and shows the ones that match, with their citations. Free, no sign-in.